Geology ReportsSearch

Geology topics

Research about Chatham County, Georgia

Source-linked reports with geographic coverage including Chatham County, Georgia.

9 recordsLinked to original sources

A brief geological history of Cockspur Island at Fort Pulaski National Monument, Chatham County, Georgia

Fort Pulaski National Monument is located on Cockspur Island in Chatham County, Georgia, within the Atlantic Coastal Plain province. The island lies near the mouth of the Savannah River, and consists of small mounds (hummocks), salt marshes, and sediment dredged from the river. A 1,017-foot (ft) (310-meter [m])-deep core drilled at Cockspur Island in 2010 by the U.S. Geological Survey revealed several sedimentary units ranging in age from 43 million years old to present. Sand and mud are present at drilling depths from 0 to 182 ft (56 m), limestone is present at depths from 182 ft (56 m) to 965 ft (295 m), and glauconitic sand is present at depths from 965 ft (295 m) to 1,017 ft (310 m). The limestone and the water within the limestone are referred to collectively as the Floridan aquifer system, which is the primary source of drinking water for the City of Savannah and surrounding communities. In addition to details of the subsurface geology, this fact sheet identifies the following geologic materials used in the construction of Fort Pulaski: (1) granite, (2) bricks, (3) sandstone, and (4) lime mud with oyster shells.

Georgia

Simulated effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Barbour Pointe, Chatham County, Georgia

Steady-state simulations using a revised regional groundwater-flow model based on MODFLOW were run to assess the potential long-term effects on the Upper Floridan aquifer (UFA) of pumping the Lower Floridan aquifer (LFA) at well 36Q398, located at Barbour Pointe in coastal Georgia near Savannah. Simulated pumping of well 36Q398 at a rate of 750 gallons per minute (gal/min; or 1.08 million gallons per day [Mgal/d]) indicated a maximum drawdown of about 2.19 feet (ft) in the UFA directly above the pumped well and at least 1 ft of drawdown within a nearly 190-square-mile area (scenario A). Induced vertical leakage from the UFA provided about 98 percent of the water to the pumped well. Simulated pumping of well 36Q398 caused increased downward leakage in all layers above the LFA, decreased upward leakage in all layers above the LFA, increased inflow to and decreased outflow from lateral specified-head boundaries in the UFA and LFA, and an increase in the volume of induced inflow from the general-head boundary representing outcrop units. Water budgets for scenario A indicated that changes in inflows and outflows through general-head boundaries would compose about 45 percent of the simulated pumpage from well 36Q398, with the remaining 55 percent of the pumped water derived from flow across lateral specified-head boundaries. Additional steady-state simulations were run to evaluate a pumping rate in the UFA of 240 gal/min (0.346 Mgal/d), which would produce an equivalent maximum drawdown in the UFA as pumping from well 36Q398 in the LFA at a rate of 750 gal/min (called the “drawdown offset”; scenario B). Simulated pumping in the UFA for the drawdown offset produced about 2.18 ft of drawdown, comparable to 2.19 ft of drawdown in the UFA simulated in scenario A. Water budgets for scenario B also provided favorable comparisons with scenario A, indicating that 42 percent of the drawdown-offset pumpage (0.346 Mgal/d) in the UFA originates as increased inflow and decreased outflow across general-head boundaries from overlying units in the surficial and Brunswick aquifer systems and that the remaining simulated pumpage originates as flow across general- and specified-head boundaries within the UFA and LFA. The revised model was evaluated for sensitivity by first altering horizontal and vertical hydraulic conductivity in the Lower Floridan semiconfining unit and then adjusting horizontal and vertical hydraulic conductivity in the LFA to match the 35.6 ft of drawdown at pumping well 36Q398. These adjustments also affected the maximum simulated drawdown in the UFA and the equivalent offset pumping in the UFA that would produce the same amount of drawdown. The maximum drawdown in the UFA ranged from 1.82 to 2.57 ft and the equivalent offset pumping in the UFA ranged from 199 to 278 gal/min. The revised model reasonably depicts changes in groundwater levels resulting from pumping the LFA at Barbour Pointe at a rate of 750 gal/min. Results are limited, however, by the same model assumptions and design as the original model, and placement of boundaries and type of boundary used exert the greatest control on overall groundwater flow and interaquifer leakage in the system. Simulation results have improved regional characterization of the Floridan aquifer system, which could be used by State officials in evaluating requests for groundwater withdrawal from the LFA.

Georgia

Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer withdrawals on the Upper Floridan aquifer at Barbour Pointe Community, Chatham County, Georgia, 2013

Two test wells were completed at the Barbour Pointe community in western Chatham County, near Savannah, Georgia, in 2013 to investigate the potential of using the Lower Floridan aquifer as a source of municipal water supply. One well was completed in the Lower Floridan aquifer at a depth of 1,080 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 440 ft below land surface. At the Barbour Pointe test site, the U.S. Geological Survey completed electromagnetic (EM) flowmeter surveys, collected and analyzed water samples from discrete depths, and completed a 72-hour aquifer test of the Floridan aquifer system withdrawing from the Lower Floridan aquifer. Based on drill cuttings, geophysical logs, and borehole EM flowmeter surveys collected at the Barbour Pointe test site, the Upper Floridan aquifer extends 369 to 567 ft below land surface, the middle semiconfining unit, separating the two aquifers, extends 567 to 714 ft below land surface, and the Lower Floridan aquifer extends 714 to 1,056 ft below land surface. A borehole EM flowmeter survey indicates that the Upper Floridan and Lower Floridan aquifers each contain four water-bearing zones. The EM flowmeter logs of the test hole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 91 percent of the total flow rate of 1,000 gallons per minute; the Lower Floridan aquifer contributed about 8 percent. Based on the transmissivity of the middle semiconfining unit and the Floridan aquifer system, the middle semiconfining unit probably contributed on the order of 1 percent of the total flow. Hydraulic properties of the Upper Floridan and Lower Floridan aquifers were estimated based on results of the EM flowmeter survey and a 72-hour aquifer test completed in Lower Floridan aquifer well 36Q398. The EM flowmeter data were analyzed using an AnalyzeHOLE-generated model to simulate upward borehole flow and determine the transmissivity of water-bearing zones. Aquifer-test data were analyzed with a two-dimensional, axisymmetric, radial, transient, groundwater-flow model using MODFLOW–2005. The flowmeter-survey and aquifer-test simulations provided an estimated transmissivity of about 60,000 square feet per day for the Upper Floridan aquifer and about 5,000 square feet per day for the Lower Floridan aquifer. Water in discrete-depth samples collected from the Upper Floridan aquifer, middle semiconfining unit, and Lower Floridan aquifer during the EM flowmeter survey in August 2013 was low in dissolved solids. Tested constituents were in concentrations within established U.S. Environmental Protection Agency drinking water-quality criteria. Concentrations of measured constituents in water samples from Lower Floridan aquifer well 36Q398 collected at the end of the 72-hour aquifer test in November 2013 were generally higher than in the discrete-depth samples collected during EM flowmeter testing in August 2013 but remained within established drinking water-quality criteria. Water-level data for the aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 ft) water-level responses to aquifer-test withdrawal. During the 72-hour aquifer test, the Lower Floridan aquifer was pumped at a rate of 750 gallons per minute resulting in a drawdown response of 35.5 ft in the pumped well; 1.6 ft in the Lower Floridan aquifer observation well located about 6,000 ft west of the pumped well; and responses of 0.7, 0.6, and 0.4 ft in the Upper Floridan aquifer observation wells located about 36 ft, 6,000 ft, and 6,800 ft from the pumped well, respectively

Georgia

Hydrogeologic characteristics and water quality of a confined sand unit in the surficial aquifer system, Hunter Army Airfield, Chatham County, Georgia

An 80-foot-deep well (36Q397, U.S. Geological Survey site identification 320146081073701) was constructed at Hunter Army Airfield to assess the potential of using the surficial aquifer system as a water source to irrigate a ballfield complex. A 300-foot-deep test hole was drilled beneath the ballfield complex to characterize the lithology and water-bearing characteristics of sediments above the Upper Floridan aquifer. The test hole was then completed as well 36Q397 open to a 19-foot-thick shallow, confined sand unit contained within the surficial aquifer system. A single-well, 24-hour aquifer test was performed by pumping well 36Q397 at a rate of 50 gallons per minute during July 13-14, 2011, to characterize the hydrologic properties of the shallow, confined sand unit. Two pumping events prior to the aquifer test affected water levels. Drawdown during all three pumping events and residual drawdown during recovery periods were simulated using the Theis formula on multiple changes in discharge rate. Simulated drawdown and residual drawdown match well with measured drawdown and residual drawdown using values of horizontal hydraulic conductivity and specific storage, which are typical for a confined sand aquifer. Based on the hydrologic parameters used to match simulated drawdown and residual drawdown to measured drawdown and residual drawdown, the transmissivity of the sand was determined to be about 400 feet squared per day. The horizontal hydraulic conductivity of the sand was determined to be about 20 feet per day. Analysis of a water-quality sample indicated that the water is suitable for irrigation. Sample analysis indicated a calcium-carbonate type water having a total dissolved solids concentration of 39 milligrams per liter. Specific conductance and concentrations of all analyzed constituents were below those that would be a concern for irrigation, and were below primary and secondary water-quality criteria levels.

Georgia

Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer, Pooler, Chatham County, Georgia, 2011–2012

Two test wells were completed in Pooler, Georgia, in 2011 to investigate the potential of using the Lower Floridan aquifer as a source of water for municipal use. One well was completed in the Lower Floridan aquifer at a depth of 1,120 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 486 ft below land surface. At the Pooler test site, the U.S. Geological Survey performed flowmeter surveys, packer-isolated slug tests within the Lower Floridan confining unit, slug tests of the entire Floridan aquifer system, and aquifer tests of the Upper and Lower Floridan aquifers. Drill cuttings, geophysical logs, and borehole flowmeter surveys indicate that the Upper Floridan aquifer extends 333 –515 ft below land surface, the Lower Floridan confining unit extends 515–702 ft below land surface, and the Lower Floridan aquifer extends 702–1,040 ft below land surface. Flowmeter surveys indicate that the Upper Floridan aquifer contains two water-bearing zones at depth intervals of 339 –350 and 375–515 ft; the Lower Floridan confining unit contains one zone at a depth interval of 550–620 ft; and the Lower Floridan aquifer contains five zones at depth intervals of 702–745, 745–925, 925–984, 984–1,015, and 1,015–1,040 ft. Flowmeter testing of the test borehole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 92.4 percent of the total flow rate of 708 gallons per minute; the Lower Floridan confining unit contributed 3.0 percent; and the Lower Floridan aquifer contributed 4.6 percent. Horizontal hydraulic conductivity of the Lower Floridan confining unit derived from slug tests within three packer-isolated intervals ranged from 0.5 to 10 feet per day (ft/d). Aquifer-test analyses yielded values of transmissivity for the Upper Floridan aquifer, Lower Floridan confining unit, and the Lower Floridan aquifer of 46,000, 700, and 4,000 feet squared per day (ft 2 /d), respectively. Horizontal hydraulic conductivity of 4 ft/d for the Lower Floridan confining unit, derived from aquifer-test analyses, is near the midrange for values derived from packer-isolated slug tests. The transmissivity of the entire Floridan aquifer system derived from aquifer-test analyses totals about 51,000 ft 2 /d, similar to the value of 58,000 ft 2 /d derived from open slug tests on the entire Floridan aquifer system. Water-level data for each aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 foot) water-level responses to aquifer-test pumping. During the 72-hour aquifer test of pumping the Lower Floridan aquifer, a drawdown response of 51.7 ft was observed in the Lower Floridan pumped well and a drawdown response of 0.9 foot was observed in the Upper Floridan observation well located 85 ft from the pumped well.

Georgia

Summary of hydrologic testing of the Floridan aquifer system at Hunter Army Airfield, Chatham County, Georgia

A 1,168-foot deep test well was completed at Hunter Army Airfield in the summer of 2009 to investigate the potential of using the Lower Floridan aquifer as a source of water supply to satisfy increased needs as a result of base expansion and increased troop levels. The U.S. Geological Survey conducted hydrologic testing at the test site including flowmeter surveys, packer-slug tests, and aquifer tests of the Upper and Lower Floridan aquifers. Flowmeter surveys were completed at different stages of well construction to determine the depth and yield of water-bearing zones and to identify confining beds that separate the main producing aquifers. During a survey when the borehole was open to both the upper and lower aquifers, five water-bearing zones in the Upper Floridan aquifer supplied 83.5 percent of the total pumpage, and five water-bearing zones in the Lower Floridan aquifer supplied the remaining 16.5 percent. An upward gradient was indicated from the ambient flowmeter survey: 7.6 gallons per minute of groundwater was detected entering the borehole between 750 and 1,069 feet below land surface, then moved upward, and exited the borehole into lower-head zones between 333 and 527 feet below land surface. During a survey of the completed Lower Floridan well, six distinct water-producing zones were identified; one 17-foot-thick zone at 768-785 feet below land surface yielded 47.9 percent of the total pumpage while the remaining five zones yielded between 2 and 15 percent each. The thickness and hydrologic properties of the confining unit separating the Upper and Lower Floridan aquifers were determined from packer tests and flowmeter surveys. This confining unit, which is composed of rocks of Middle Eocene age, is approximately 160 feet thick with horizontal hydraulic conductivities determined from four slug tests to range from 0.2 to 3 feet per day. Results of two separate slug tests within the middle confining unit were both 2 feet per day. Aquifer testing indicated the Upper Floridan aquifer had a transmissivity of 40,000 feet squared per day, and the Lower Floridan aquifer had a transmissivity of 10,000 feet squared per day. An aquifer test conducted on the combined aquifer system, when the test well was open from 333 to 1,112 feet, gave a transmissivity of 50,000 feet squared per day. Additionally, during the 72-hour test of the Lower Floridan aquifer, a drawdown response was observed in the Upper Floridan aquifer wells.

Georgia

Hydrology, water quality, and water-supply potential of ponds at Hunter Army Airfield, Chatham County, Georgia, November 2008-July 2009

The hydrology, water quality, and water-supply potential of four ponds constructed to capture stormwater runoff at Hunter Army Airfield, Chatham County, Georgia, were evaluated as potential sources of supplemental irrigation supply. The ponds are, Oglethorpe Lake, Halstrum Pond, Wilson Gate Pond, and golf course pond. During the dry season, when irrigation demand is highest, ponds maintain water levels primarily from groundwater seepage. The availability of water from ponds during dry periods is controlled by the permeability of surficial deposits, precipitation and evaporation, and the volume of water stored in the pond. Net groundwater seepage (Gnet) was estimated using a water-budget approach that used onsite and nearby climatic and hydrologic data collected during November-December 2008 including precipitation, evaporation, pond stage, and discharge. Gnet was estimated at three of the four sites?Oglethorpe Lake, Halstrum Pond, and Wilson Gate Pond?during November-December 2008. Pond storage volume in the three ponds ranged from 5.34 to 12.8 million gallons. During November-December 2008, cumulative Gnet ranged from -5.74 gallons per minute (gal/min), indicating a net loss in pond volume, to 19 gal/min, indicating a net gain in pond volume. During several periods of stage recovery, daily Gnet rates were higher than the 2-month cumulative amount, with the highest rates of 178 to 424 gal/min following major rainfall events during limited periods. These high rates may include some contribution from stormwater runoff; more typical recovery rates were from 23 to 223 gal/min. A conservative estimate of the volume of water available for irrigation supply from three of the ponds was provided by computing the rate of depletion of pond volume for a variety of withdrawal rates based on long-term average July precipitation and evaporation and the lowest estimated Gnet rate at each pond. Withdrawal rates of 1,000, 500, and 250 gal/min were applied during an 8-hour daily pumping period. At a withdrawal rate of 1,000 gal/min, available pond volume would be depleted in 13-29 days, at a rate of 500 gal/min in 24-60 days, and at a rate of 250 gal/min, in 44 to 130 days. In each case, Halstrum Pond had the largest amount of available pond volume. The water-supply potential at the golf course pond was assessed by measuring flow downstream from the pond during February-July 2009, and examining historic stormflow measurements collected during 1979-87. Streamflow during both of these periods exceeded average daily (2005-2007) golf course water use. Assuming an 8-hour daily irrigation period, the average discharge rate required to meet Golf Course water demand during peak demand months of March-May and July-October exceeds 200 gal/min, with the greatest rate of 531 gal/min during July. During February-July 2009, daily average streamflow downstream of the golf course pond exceeded 238 gal/min 90 percent of the time. Based on samples collected for chemical analysis during April 2009, water from all four ponds at Hunter Army Airfield is fresh and suitable for irrigation supply, with chloride concentrations below 12 milligrams per liter. With the exception of iron in Wilson Gate Pond, constituent concentrations are below U.S. Environmental Protection Agency primary and secondary drinking water maximum contaminant levels. Water in Wilson Gate Pond contained an iron concentration of 419 mg/L, which exceeds the secondary maximum contaminant level of 300 micrograms per liter. Although not a health hazard, when the iron concentration exceeds 300 micrograms per liter, iron staining of sidewalks and plumbing fixtures may occur. Levels of dissolved oxygen were below the Georgia Environmental Protection Divison standard of 4 milligrams per liter for waters supporting warm-water fishes at deeper depths in Oglethorpe Lake, Wilson Gate Pond, and Halstrum Pond, and in the composite sample at the golf course pond.

Georgia

Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Hunter Army Airfield, Chatham County, Georgia

Test drilling and field investigations, conducted at Hunter Army Airfield (HAAF), Chatham County, Georgia, during 2009, were used to determine the geologic, hydraulic, and water-quality characteristics of the Floridan aquifer system and to evaluate the effect of Lower Floridan aquifer (LFA) pumping on the Upper Floridan aquifer (UFA). Field investigation activities included (1) constructing a 1,168-foot (ft) test boring and well completed in the LFA, (2) collecting drill cuttings and borehole geophysical logs, (3) collecting core samples for analysis of vertical hydraulic conductivity and porosity, (4) conducting flowmeter and packer tests in the open borehole within the UFA and LFA, (5) collecting depth-integrated water samples to assess basic ionic chemistry of various water-bearing zones, and (6) conducting aquifer tests in the new LFA well and in an existing UFA well to determine hydraulic properties and assess interaquifer leakage. Using data collected at the site and in nearby areas, model simulation was used to quantify the effects of interaquifer leakage on the UFA and to determine the amount of pumping reduction required in the UFA to offset drawdown resulting from the leakage. Borehole-geophysical and flowmeter data indicate the LFA at HAAF consists of limestone and dolomitic limestone between depths of 703 and 1,080 ft, producing water from six major permeable zones: 723-731; 768-785; 818-837; 917-923; 1,027-1,052; and 1,060-1,080 ft. Data from a flowmeter survey, conducted at a pumping rate of 748 gallons per minute (gal/min), suggest that the two uppermost zones contributed 469 gal/min or 62.6 percent of the total flow during the test. The remaining four zones contributed from 1.7 to 18 percent of the total flow. Grab water samples indicate that with the exception of fluoride, constituent concentrations in the LFA increased with depth; water from the deepest interval (1,075 ft) contained chloride and sulfate concentrations of 480 and 240 milligrams per liter (mg/L), respectively. These relatively high concentrations were interpreted to have little effect on the overall quality of the well because flowmeter results indicated that water from 1,060 to 1,080 ft contributed less than 2 percent of the total flow to the completed well. Results of a 72-hour aquifer test indicate that pumping a LFA well at a rate of 748 gal/min produced a drawdown response of 0.76 ft in a well completed in the UFA located 176 ft from the pumped well. A revised regional groundwater-flow model was used to simulate long-term (steady-state) leakage response of the UFA to pumping from the LFA and to estimate the equivalent amount of pumping from the UFA that would produce similar drawdown. Pumping the well at a rate of 748 gal/min (about 1 million gallons per day [Mgal/d]) resulted in a maximum simulated steady-state drawdown of 36.2 ft in the LFA and was greater than 1 ft over a 146 square-mile area. Simulated steady-state drawdown in the overlying UFA that resulted from interaquifer leakage was greater than 1 ft over a 141 square-mile area and was 2.03 ft at the pumped well. Flow to the pumped well was derived from increased lateral flow across the specified-head boundary (0.02 Mgal/d) and increased leakage from the UFA (0.52 Mgal/d), and by reductions in discharge to the Lower Floridan confining unit (0.53 Mgal/d) and to the lateral specified-head boundary (0.53 Mgal/d). Sixty-five percent of the leakage from the UFA occurred within 1 mile of the pumped well. This larger contribution results from a larger head gradient between the pumped well and the overlying aquifer in areas close to the pumped well. The Georgia Environmental Protection Division interim permitting strategy for the LFA requires simulation of (1) aquifer leakage from the UFA to LFA resulting from pumping the new LFA well, and (2) the equivalent rate of UFA pumping that induces the identical maximum drawdown in the UFA that would be expected as a result of pumping th

Georgia