Geology Reports⌕ Search

Geology topics

Research about Cape Cod

Source-linked reports with geographic coverage including Cape Cod.

At least 55 records · Page 3Linked to original sources

Geological interpretation of bathymetric and backscatter imagery of the sea floor off eastern Cape Cod, Massachusetts

The imagery, interpretive data layers, and data presented herein were derived from multibeam echo-sounder data collected off Eastern Cape Cod, Massachusetts, and from the stations occupied to verify these acoustic data. The basic data layers show sea-floor topography, sun-illuminated shaded relief, and backscatter intensity; interpretive layers show the distributions of surficial sediment and sedimentary environments. Presented verification data include new and historical sediment grain-size analyses and a gallery of still photographs of the seabed. The multibeam data, which cover a narrow band of the sea floor extending from Provincetown around the northern tip of Cape Cod and south southeastward to off Monomoy Island, were collected during transits between concurrent mapping projects in the Stellwagen Bank National Marine Sanctuary (Valentine and others, 2001; Butman and others, 2004; and Valentine, 2005) and Great South Channel (Valentine and others, 2003a, b, c, d). Although originally collected to maximize the use of time aboard ship, these data provide a fundamental framework for research and management activities in this part of the Gulf of Maine (Noji and others, 2004), show the composition and terrain of the seabed, and provide information on sediment transport and benthic habitat. These data and interpretations also support ongoing modeling studies of the lower Cape’s aquifer system (Masterson, 2004) and of erosional hotspots along the Cape Cod National Seashore (List and others, 2006).

Massachusetts↗

Ground-water levels near the top of the water-table mound, western Cape Cod, Massachusetts, 2002-04

In January 2002 the U.S. Geological Survey began continuous water-level monitoring in three wells in the vicinity of the Southeast Ranges of Camp Edwards, near the Impact Area of the Massachusetts Military Reservation on Cape Cod. The purpose of this effort was to examine how water levels at sites with different unsaturated-zone thicknesses near the top of the water-table mound beneath western Cape Cod are affected by temporally variable recharge from precipitation, which is the sole source of water to the sand and gravel aquifer. The depths to water at the well sites are about 18, 30, and 101 feet below land surface. This report presents the first 3 years of water-level records and an estimate of aquifer recharge calculated from climatological measurements by the Jensen and Haise method and the Thornthwaite method. The water levels in the three wells varied temporally by about 4.5 feet during the study period. A comparison of the water levels with those measured in a nearby monitoring well with about 42 years of monthly measurements indicates that the 3-year monitoring period included the lowest water levels on western Cape Cod since the drought of the 1960's. The response of water levels to recharge was related to the depth to water. Water levels in the two wells with shallow depths to water responded quickly (within hours or days) to recharge, whereas the water-level response in the well with the greatest depth to water often lagged the recharge event by a month or more. The variations in the water levels among the wells changed as the location of the top of the water-table mound moved with the changing water-table altitude.

Massachusetts↗

Transient Analysis of the Source of Water to Wells: Cape Cod, Massachusetts

A transient flow modeling analysis for potential public-supply wells on western Cape Cod, Massachusetts, demonstrates the difference between transient and steady-state recharge areas can have important implications for wellhead protection. An example of a single pumping well illustrates that commonly, used steady-state time-related capture areas do not represent the recharge area and travel times of water being pumped from the well until sufficient time has elapsed for steady-state flow conditions to be established. Until that time, transient recharge areas are needed to account for the portion of water discharging from the well that entered the aquifer before pumping started. An example of two pumping wells demonstrates the same area at the water table cannot supply water to more than one well under steady-state flow conditions. Transient recharge areas to multiple wells can overlap, however, until steady-state flow conditions are established. The same area can, therefore, be a source of water to more than one well during early pumping times, and the water pumped from a given well may derive from source areas, including contaminated areas, that do not lie within the well's steady-state recharge area.

Cape Cod↗

Changes in ground-water quality near two granular-iron permeable reactive barriers in a sand and gravel aquifer, Cape Cod, Massachusetts, 1997-2000

Two experimental permeable reactive barriers (PRBs) of granular zero-valent iron were emplaced in the path of a tetrachloroethene plume (the Chemical Spill-10 plume) at the Massachusetts Military Reservation, Cape Cod, Massachusetts, in June 1998. The goal of the field experiment was to achieve emplacement of a granular-iron PRB deeper than attempted before. The PRBs were expected to create a reducing environment and degrade the tetrachloroethene by reductive dechlorination. The goal of the work presented in this report was to observe temporary and sustained changes to the ground-water chemistry downgradient from the PRBs. A hydraulic-fracturing method involving injection of the granular iron with a guar-biopolymer and enzyme slurry was used to install the parallel 30- to 33-foot-wide wall-shaped barriers at a depth of 82 to 113 feet below land surface. An acetic acid and enzyme mixture was subsequently injected in wells near the barriers to degrade the guar biopolymer. Prior to the emplacement, tetrachloroethene concentrations in the Chemical Spill-10 plume at the study area were as high as 250 micrograms per liter. Other water properties in the plume generally were similar to the properties of uncontaminated ground water in the area, which typically has dissolved oxygen concentrations of 250 to 375 micromoles per liter, pH of 5.5 to 6.0, and specific conductance of 60 to 90 microsiemens per centimeter. Water-quality samples were collected periodically from monitoring wells near the PRBs to determine how the emplacement of the granular-iron walls altered the ground-water quality. In addition, an automated well-sampling device measured temperature, specific conductance, pH, and dissolved oxygen every 1–4 days for 16 months in a well downgradient from the two parallel PRBs. Temporary increases (lasting about 5 to 6 months) in specific conductance were observed downgradient from the PRBs as a result of the sodium chloride, potassium carbonate, and other salts included in the slurry and the acetic acid and enzyme mixture that was subsequently injected to degrade the guar biopolymer. Temporary increases in the concentrations of major cations (sodium, potassium, magnesium, and calcium) were observed downgradient from the PRBs, as were temporary but substantial increases in the dissolved and total organic carbon concentrations. Methane was detected, sulfate concentrations decreased temporarily, and concentrations of dissolved inorganic carbon increased in samples from wells downgradient from the PRBs. A sustained (longer than 12 months) reducing environment, in which dissolved oxygen concentrations decreased to zero, the pH increased to about 6.8, and dissolved iron concentrations increased substantially, developed as a result of the oxidation (corrosion) of the granular iron; this zone persisted at least 65 feet downgradient from the PRBs. The pH and dissolved iron concentrations increased with distance from the granular-iron walls. Concentrations of arsenic, cobalt, manganese, and phosphorus increased, and nitrate concentrations were reduced to below the detection limit downgradient from the walls. A sustained decrease of tetrachloroethene concentrations was not observed; however, reductive dechlorination products were observed at wells downgradient from the PRBs during several rounds of sampling. The emplacement of zero-valent iron in the aquifer to remove tetrachloroethene from the ground water caused changes in the water chemistry that persisted farther downgradient from the PRBs than has been observed at other sites because of the low chemical reactivity of the quartz-dominated aquifer sediments and the low ambient dissolved chemical concentrations in the ground water. The small transverse dispersion in the aquifer and the probable long-term persistence of the iron indicate that the chemically altered zone probably will extend a substantial distance downgradient from the PRBs for a substantial period of time (years); further investigation would be needed to determine this distance.

Massachusetts↗

Petrography and character of the bedrock surface beneath western Cape Cod, Massachusetts

Cores collected during recent drilling in western Cape Cod, Massachusetts provide insight into the topography and petrology of the underlying bedrock. 62 drill sites spread over a ???140 km2 study area produced cores of granitoids (31), orthogneisses (20), basalts/diabases (4), amphibolites (3), felsic mylonites (2), and dolomitic rock (2). Granitoid cores range in composition from granite to tonalite to quartz diorite, but are dominated by single-mica granites. Alteration is common in nearly all cores examined in this study, and is evidenced by the secondary growth of chlorite and epidote. The granitoids resemble rocks of the Dedham and Fall River terranes (Wones and Goldsmith 1991). Gneisses from the study area generally contain the mineral assemblage hornblende+plagioclase+quartz+biotite+epidote??chlorite?? sphene??K-feldspar??sericite+oxides. Based on mineral assemblages, we estimate peak metamorphic grade to be of lower amphibolite facies. X-ray powder diffraction of unmetamorphosed dolomitic cores shows presence of layered silicates (clays), plagioclase, and possible magnesite. Contours of the bedrock surface show locally irregular topography suggesting erosion by glacial scour. The distribution of lithologies suggests a possible continuation of the New Bedford gneissic terrane that outcrops 25 km to the west. Dolomitic rocks may represent a lithified fault gouge material at the eastern edge of the gneissic zone. Basalts/diabases are interpreted to be post-metamorphic dikes of Late Paleozoic age, or possibly associated with Mesozoic rifting.

Massachussets↗

Applicability of tetrazolium salts for the measurement of respiratory activity and viability of groundwater bacteria

A study was undertaken to measure aerobic respiration by indigenous bacteria in a sand and gravel aquifer on western Cape Cod, MA using tetrazolium salts and by direct oxygen consumption using gas chromatography (GC). In groundwater and aquifer slurries, the rate of aerobic respiration calculated from the direct GC assay was more than 600 times greater than that using the tetrazolium salt 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl tetrazolium chloride (INT). To explain this discrepancy, the toxicity of INT and two additional tetrazolium salts, sodium 3′-[1-(phenylamino)-carbonyl]-3,4-tetrazolium]-bis(4-methoxy-6-nitro) benzenesulfonic acid hydrate (XTT) and 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), to bacterial isolates from the aquifer was investigated. Each of the three tetrazolium salts was observed to be toxic to some of the groundwater isolates at concentrations normally used in electron transport system (ETS) and viability assays. For example, incubation of cells with XTT (3 mM) caused the density of four of the five groundwater strains tested to decline by more than four orders of magnitude. A reasonable percentage (>57%) of cells killed by CTC and INT contained visible formazan crystals (the insoluble, reduced form of the salts) after 4 h of incubation. Thus, many of the cells reduced enough CTC or INT prior to dying to be considered viable by microscopic evaluation. However, one bacterium ( Pseudomonas fluorescens ) that remained viable and culturable in the presence of INT and CTC, did not incorporate formazan crystals into more than a few percent of cells, even after 24 h of incubation. This strain would be considered nonviable based on traditional tetrazolium salt reduction assays. The data show that tetrazolium salt assays are likely to dramatically underestimate total ETS activity in groundwater and, although they may provide a reasonable overall estimate of viable cell numbers in a community of groundwater bacteria, some specific strains may be falsely considered nonviable by this assay due to poor uptake or reduction of the salts.

Massachusetts↗

Coastal vulnerability assessment of Cape Cod National Seashore to sea-level rise

A coastal vulnerability index (CVI) was used to map the relative vulnerability of the coast to future sea-level rise within the Cape Cod National Seashore (CACO). The CVI ranks the following in terms of their physical contribution to sea-level rise-related coastal change: geomorphology, regional coastal slope, rate of relative sea-level rise, shoreline change rates, mean tidal range and mean wave height. The rankings for each variable were combined and an index value calculated for 1-minute grid cells covering the park. The CVI highlights those regions where the physical effects of sea-level rise might be the greatest. This approach combines the coastal system's susceptibility to change with its natural ability to adapt to changing environmental conditions, yielding a quantitative, although relative, measure of the park's natural vulnerability to the effects of sea-level rise. CACO consists of high glacial cliffs, beaches, sand spits, and salt marsh wetlands. The areas most vulnerable to sea-level rise are those with the lowest regional coastal slopes, geomorphologic types that are susceptible to inundation, and the highest rates of shoreline change. Most of CACO's infrastructure lies on high elevation uplands away from the shore; most high use areas are accessible by foot only. The CVI provides an objective technique for evaluation and long-term planning by scientists and park managers.

Massachusetts↗

Long-term hydrologic monitoring protocol for coastal ecosystems

The Cape Cod National Seashore serves as a National Park Service prototype-monitoring park for the Atlantic and Gulf Coast biogeographic region. The U.S. Geological Survey, in cooperation with the National Park Service, is charged with designing and testing monitoring protocols for implementation at the Cape Cod National Seashore. It is expected that many of the protocols will have direct application at other coastal park units, as well as U.S. Fish and Wildlife Service coastal refuges, within the biogeographic region. The Long-term Coastal Ecosystem Monitoring Program at the Cape Cod National Seashore will rely upon numerous protocols that are relevant to the major ecosystem types (Estuaries and Salt Marshes, Barrier Islands/Spits/Dunes, Ponds and Freshwater Wetlands, Coastal Uplands). The hydrologic monitoring protocol is associated with all of these ecosystem types. The overall monitoring program is designed so that all of the protocols are interrelated. Roman and Barrett (1999)present a conceptual description of the entire monitoring program.

Massachusetts↗

Phosphorus in a ground-water contaminant plume discharging to Ashumet Pond, Cape Cod, Massachusetts, 1999

The discharge of a plume of sewagecontaminated ground water emanating from the Massachusetts Military Reservation to Ashumet Pond on Cape Cod, Massachusetts, has caused concern about excessive loading of nutrients, particularly phosphorus, to the pond. The U.S. Air Force is considering remedial actions to mitigate potentially adverse effects on the ecological characteristics of the pond from continued phosphorus loading. Concentrations as great as 3 milligrams per liter of dissolved phosphorus (as P) are in ground water near the pond's shoreline; concentrations greater than 5 milligrams per liter of phosphorus are in ground water farther upgradient. Temporary drive-point wells were used to collect water samples from 2 feet below the pond bottom to delineate concentration distributions in the pore waters of the pond-bottom sediments. Measurements in the field of specific conductance and colorimetrically determined orthophosphate concentrations provided real-time data to guide the sampling. The contaminant plume discharges to the Fishermans Cove area of Ashumet Pond as evidenced by elevated levels of specific conductance and boron, which are chemically conservative indicators of the sewage-contaminated ground water. Concentrations of nonconservative species, such as dissolved phosphorus, manganese, nitrate, and ammonium, also were elevated above background levels in ground water discharging to the pond, but in spatially complex distributions that reflect their distributions in ground water upgradient of the pond. Phosphorus concentrations exceeded background levels (greater than 0.10 milligram per liter) in the pond-bottom pore water along 875 feet of shoreline. Greatest concentrations (greater than 2 milligrams per liter) occurred within 30 feet of the shore in an area about 225 feet long. Calculations of phosphorus flux in the aquifer upgradient of Ashumet Pond, as determined from water-flux estimates from a steady-state ground-water-flow model and phosphorus concentrations (in 1999) from multilevel samplers about 75 feet upgradient of the pond, indicate that dissolved phosphorus moves towards the pond and discharges to it with the inflowing ground water at a rate as high as about 316 kilograms per year.

Massachusetts↗

Reactive-transport simulation of phosphorus in the sewage plume at the Massachusetts Military Reservation, Cape Cod, Massachusetts

The subsurface transport of phosphorus introduced by the disposal of treated sewage effluent to ground-infiltration disposal beds at the Massachusetts Military Reservation on western Cape Cod was simulated with a three-dimensional reactive-transport model. The simulations were used to estimate the load of phosphorus transported to Ashumet Pond during operation of the sewage-treatment plant from 1936 to 1995 and for 60 years following cessation of sewage disposal. The model accounted for spatial and temporal changes in water discharge from the sewage-treatment plant, ground-water flow, transport of associated chemical constituents, and a set of chemical reactions, including phosphorus sorption on aquifer materials, dissolution and precipitation of iron- and manganese-oxyhydroxide and iron phosphate minerals, organic carbon sorption and decomposition, cation sorption, and irreversible denitrification. The flow and transport in the aquifer were simulated by using parameters consistent with those used in previous flow models of this area of Cape Cod, except that numerical dispersion was much larger than the physical dispersion estimated in previous studies. Sorption parameters were fit to data derived from phosphorus sorption and desorption laboratory column experiments. Rates of organic carbon decomposition were adjusted to match the location of iron concentrations in an anoxic iron zone within the sewage plume. The sensitivity of the simulated load of phosphorus transported to Ashumet Pond was calculated for a variety of processes and input parameters. Model limitations included large uncertainties associated with the loading of the sewage beds, the flow system, and the chemistry and sorption characteristics in the aquifer. The results of current model simulations indicate a small load of phosphorus transported to Ashumet Pond during 1965-85, but this small load was particularly sensitive to model parameters that specify flow conditions and the chemical process by which non-desorbable phosphorus is incorporated in the sediments. The uncertainties were large enough to make it difficult to determine whether loads of phosphorus transported to Ashumet Pond in the 1990s were greater or less than loads during the previous two decades. The model simulations indicate substantial discharge of phosphorus to Ashumet Pond after about 1965. After the period 2000-10 the simulations indicate that the load of phosphorus transported to Ashumet Pond decreases continuously, but the load of phosphorus remains substantial for many decades. The current simulations indicate a peak in phosphorus discharge to Ashumet Pond of about 1,000 kilograms per year during the 1990s; however, comparisons of simulated phosphorus concentrations with measured concentrations in 1993 indicate that the peak in phosphorus load transported to Ashumet Pond may be larger and moving more quickly in the model simulations than in the aquifer. The results of the three-dimensional reactive-transport simulations are consistent with the loading history, experimental laboratory data, and field measurements. The results of the simulations adequately reproduce the spatial distribution of phosphorus concentrations measured in 1993, the magnitude of changes in phosphorus concentration with time in a profile near the disposal beds following cessation of sewage disposal, the observed iron zone in the sewage plume, the approximate flow of treated sewage effluent into Ashumet Valley, and laboratory-column data for phosphorus sorption and desorption.

Massachusetts↗

Simulation of advective flow under steady-state and transient recharge conditions, Camp Edwards, Massachusetts Military Reservation, Cape Cod, Massachusetts

The U.S. Geological Survey has developed several ground-water models in support of an investigation of ground-water contamination being conducted by the Army National Guard Bureau at Camp Edwards, Massachusetts Military Reservation on western Cape Cod, Massachusetts. Regional and subregional steady-state models and regional transient models were used to (1) improve understanding of the hydrologic system, (2) simulate advective transport of contaminants, (3) delineate recharge areas to municipal wells, and (4) evaluate how model discretization and time-varying recharge affect simulation results. A water-table mound dominates ground-water-flow patterns. Near the top of the mound, which is within Camp Edwards, hydraulic gradients are nearly vertically downward and horizontal gradients are small. In downgradient areas that are further from the top of the water-table mound, the ratio of horizontal to vertical gradients is larger and horizontal flow predominates. The steady-state regional model adequately simulates advective transport in some areas of the aquifer; however, simulation of ground-water flow in areas with local hydrologic boundaries, such as ponds, requires more finely discretized subregional models. Subregional models also are needed to delineate recharge areas to municipal wells that are inadequately represented in the regional model or are near other pumped wells. Long-term changes in recharge rates affect hydraulic heads in the aquifer and shift the position of the top of the water-table mound. Hydraulic-gradient directions do not change over time in downgradient areas, whereas they do change substantially with temporal changes in recharge near the top of the water-table mound. The assumption of steady-state hydraulic conditions is valid in downgradient area, where advective transport paths change little over time. In areas closer to the top of the water-table mound, advective transport paths change as a function of time, transient and steady-state paths do not coincide, and the assumption of steady-state conditions is not valid. The simulation results indicate that several modeling tools are needed to adequately simulate ground-water flow at the site and that the utility of a model varies according to hydrologic conditions in the specific areas of interest.

Massachusetts↗

Diffusion and drive-point sampling to detect ordnance-related compounds in shallow ground water beneath Snake Pond, Cape Cod, Massachusetts, 2001-02

Diffusion samplers and temporary drive points were used to test for ordnance-related compounds in ground water discharging to Snake Pond near Camp Edwards at the Massachusetts Military Reservation, Cape Cod, MA. The contamination resulted from artillery use and weapons testing at various ranges upgradient of the pond.The diffusion samplers were constructed with a high-grade cellulose membrane that allowed diffusion of explosive compounds, such as RDX (Hexahydro-1,3,5-trinitro-1,3,5-triazine) and HMX (Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine), into deionized water inside the samplers. Laboratory tests confirmed that the cellulose membrane was permeable to RDX and HMX. One transect of 22 diffusion samplers was installed and retrieved in August-September 2001, and 12 transects with a total of 108 samplers were installed and retrieved in September-October 2001. The diffusion samplers were buried about 0.5 feet into the pond-bottom sediments by scuba divers and allowed to equilibrate with the ground water beneath the pond bottom for 13 to 27 days before retrieval. Water samples were collected from temporary well points driven about 2-4 feet into the pond bottom at 21 sites in December 2001 and March 2002 for analysis of explosives and perchlorate to confirm the diffusion-sampling results. The water samples from the diffusion samplers exhibited numerous chromatographic peaks, but evaluation of the photo-diode-array spectra indicated that most of the peaks did not represent the target compounds. The peaks probably are associated with natural organic compounds present in the soft, organically enriched pond-bottom sediments. The presence of four explosive compounds at five widely spaced sites was confirmed by the photo-diode-array analysis, but the compounds are not generally found in contaminated ground water near the ranges. No explosives were detected in water samples obtained from the drive points. Perchlorate was detected at less than 1 microgram per liter in two drive-point samples collected at the same site on two dates about 3 months apart. The source of the perchlorate in the samples could not be related directly to other contamination from Camp Edwards with the available information. The results from the diffusion and drive-point sampling do not indicate an area of ground-water discharge with concentrations of the ordnance-related compounds that are sufficiently elevated to be detected by these sampling methods. The diffusion and drive-point sampling data cannot be interpreted further without additional information concerning the pattern of ground-water flow at Snake Pond and the distributions of RDX, HMX, and perchlorate in ground water in the aquifer near the pond.

Massachusetts↗

Field evidence for a protistan role in an organically-contaminated aquifer

The association between protists, bacteria, and dissolved organic carbon (DOC) in an oxygen-depleted, 6 km-long wastewater contaminant plume within a sandy aquifer (Cape Cod, MA) was investigated by comparing abundance patterns along longitudinal and vertical transects and at a control site. Strong linear correlations were observed between unattached bacterial abundance and DOC for much of the upgradient-half of the plume (0.1−2.5 km downgradient from the source) that is characterized by quasi-steady state chemistry. However, a logarithmic decrease was observed between the number of protists supported per mg of DOC and the estimated age of the DOC within the plume. The relatively labile dissolved organic contaminants that characterize the groundwater sampled from the plume ≤0.1 km downgradient from the contaminant source appeared to indirectly support 3−4 times as many protists (per mg of DOC) as the older, more recalcitrant DOC in the alkylbenzene sulfonate (ABS)-contaminated zone at 3 km downgradient (∼30 years travel time). Substantive numbers of protists (>10 4 /cm 3 ) were recovered from suboxic zones of the plume. The higher than expected ratios of protists to unattached bacteria (10 to 100:1) observed in much of the plume suggest that protists may be grazing upon both surface-associated and unattached bacterial communities to meet their nutritional requirements. In closed bottle incubation experiments, the presence of protists caused an increase in bacterial growth rate, which became more apparent at higher amendments of labile DOC (3−20 mgC/L). The presence of protists resulted in an increase in the apparent substrate saturation level for the unattached bacterial community, suggesting an important role for protists in the fate of more-labile aquifer organic contaminants.

Massachusetts↗

Multispecies reactive tracer test in an aquifer with spatially variable chemical conditions, Cape Cod, Massachusetts: Dispersive transport of bromide and nickel

Dispersive transport of groundwater solutes was investigated as part of a multispecies reactive tracer test conducted under spatially variable chemical conditions in an unconfined, sewage‐contaminated sand and gravel aquifer on Cape Cod, Massachusetts. Transport of the nonreactive tracer bromide (Br) reflected physical and hydrologic processes. Transport of the reactive tracer nickel (Ni) complexed with an organic ligand (NiEDTA) varied in response to pH and other chemical conditions within the aquifer. A loss of about 14% of the Ni mass was calculated from the distribution of tracers through time. This loss is consistent with reversible adsorption of NiEDTA onto the iron and aluminum oxyhydroxide coatings on the aquifer sediments. The Ni consistently lagged behind Br with a calculated retardation coefficient of 1.2. Longitudinal dispersivities reached constant values of 2.2 and 1.1 m for Br and Ni, respectively, by at least 69 m of travel. The smaller dispersivity for Ni possibly was due to nonlinear or spatially variant adsorption of NiEDTA. In the upper, uncontaminated zone of the aquifer, longitudinal dispersion of Ni was greater than that of Br early in the test as a result of reversible adsorption of NiEDTA. In general, transverse dispersivities were much smaller (horizontal: 1.4–1.5 × 10 −2 m; vertical: 0.5–3.8 × 10 −3 m) than the longitudinal dispersivities. The Br results are similar to those from a test conducted eight years earlier, suggesting that transport parameters are spatially stationary within the aquifer at the scale of 300 m covered by the spatially overlapping tests. A significant difference between the two tests was the travel distance (69 and 26 m) needed to reach a constant longitudinal dispersivity.

Massachusetts↗

Simulated changes in the sources of ground water for public-supply wells, ponds, streams, and coastal areas on western Cape Cod, Massachusetts

The U.S. Geological Survey, in cooperation with the Air Force Center for Environmental Excellence, developed a three-dimensional ground-water-flow model to simulate sources of water to public-supply wells, ponds, streams, and coastal areas for average and changing pumping and recharge conditions on western Cape Cod, Massachusetts. Understanding the changing sources of water that flows to these discharge areas under changing hydrologic conditions and stresses is needed to help water-resource managers protect the quality of the drinking water and the water resources of western Cape Cod. The interconnection of hydrologic features through the ground-water-flow system on Cape Cod complicates the determination of the sources of water for changing pumping and recharge conditions. When pumping and recharge conditions change, the numerical model can help evaluate changes in the recharge areas to pumped wells, ponds, streams, and coastal areas. The steady-state recharge area and time-of-travel zones to a pumping well represent the source of water and time of travel from the water table to the well once all of the water discharging to the well entered the aquifer after pumping began. Initially, the water that discharges to a pumped well over a specified period consists of a blend of waters that entered the aquifer over time. When pumping begins, a deep well may capture water that entered the aquifer many years earlier at a great distance from the well; therefore, determining the source of water discharging to a well for specified pumping times may be more important for protecting public-water supplies than determining only the steady-state recharge area and time-of-travel zones to the well.

Massachusetts↗

Simulated pond-aquifer interactions under natural and stressed conditions near Snake Pond, Cape Cod, Massachusetts

A numerical model was used to simulate pond-aquifer interactions under natural and stressed conditions near Snake Pond, Cape Cod, Massachusetts. Simulation results show that pond-bottom hydraulic conductivity, which represents the degree of hydraulic connection between the pond and the aquifer, is an important control on these interactions. As this parameter was incrementally increased from 10 to 350 feet per day, the rate of ground-water inflow into the pond under natural conditions increased by about 250 percent, the associated residence times of water in the pond decreased by about 50 percent, and ground-water inflow to the pond shifted closer to the pond shore. Most ground-water inflow (90 to 98 percent) was in the upper model layer, which corresponded to shallow, near-shore areas of the pond, over the entire range of pond-bottom hydraulic conductivity. Ground-water flow paths into the pond became more vertical, the contributing area to the pond became larger, and the pond captured water from greater depths in the aquifer as the hydraulic conductivity of the pond bottom was increased. The pond level, however, remained nearly constant, and regional ground-water levels and gradients differed little over the range of pond-bottom hydraulic conductivity, indicating that calibrated models with similar head solutions can have different pond-aquifer interaction characteristics. Hydrologic stresses caused by a simulated plume-containment system that specifies the extraction and injection of large volumes of ground water near the pond increased the pond level by about 0.4 foot and ground-water inflow rates into the pond by about 25 percent. Several factors related to the operation of the simulated containment system are affected by the hydraulic conductivity of the pond bottom. With increasing pond-bottom hydraulic conductivity, the amount of injected water that flows into Snake Pond increased and the amount of water recirculated between extraction and injection wells decreased. Comparison of simulations in which pond-bottom hydraulic conductivity was varied throughout the pond and simulations in which hydraulic conductivity was varied only in areas corresponding to shallow, near-shore areas of the pond indicate that the simulated hydraulic conductivity of the pond bottom in deeper parts of the pond had little effect on pond-aquifer interactions under both natural and stressed conditions.

Massachusetts↗

Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table.

Massachusetts↗

Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table. The aquifer was pumped at a rate of 320 gallons per minute for 72-hours and drawdown measurements were made in the pumped well and in 20 piezometers located at various distances from the pumped well and depths below the land surface. To facilitate the analysis, an automatic parameter estimation algorithm was used to obtain relevant unconfined aquifer parameters, including the saturated thickness and a set of empirical parameters that relate to gradual drainage from the unsaturated zone. Drainage from the unsaturated zone is treated in this paper as a finite series of exponential terms, each of which contains one empirical parameter that is to be determined. It was necessary to account for effects of gradual drainage from the unsaturated zone to obtain satisfactory agreement between measured and simulated drawdown, particularly in piezometers located near the water table. The commonly used assumption of instantaneous drainage from the unsaturated zone gives rise to large discrepancies between measured and predicted drawdown in the intermediate-time range and can result in inaccurate estimates of aquifer parameters when automatic parameter estimation procedures are used. The values of the estimated hydraulic parameters are consistent with estimates from prior studies and from what is known about the aquifer at the site. Effects of heterogeneity at the site were small as measured drawdowns in all piezometers and wells were very close to the simulated values for a homogeneous porous medium. The estimated values are: specific yield, 0.26; saturated thickness, 170 feet; horizontal hydraulic conductivity, 0.23 feet per minute; vertical hydraulic conductivity, 0.14 feet per minute; and specific storage, 1.3x10-5 per foot. It was found that drawdown in only a few piezometers strategically located at depth near the pumped well yielded parameter estimates close to the estimates obtained for the entire data set analyzed simultaneously. If the influence of gradual drainage from the unsaturated zone is not taken into account, specific yield is significantly underestimated even in these deep-seated piezometers. This helps to explain the low values of specific yield often reported for granular aquifers in the literature. If either the entire data set or only the drawdown in selected deep-seated piezometers was used, it was found unnecessary to conduct the test for the full 72-hours to obtain accurate estimates of the hydraulic parameters. For some piezometer groups, practically identical results would be obtained for an aquifer test conducted for only 8-hours. Drawdowns measured in the pumped well and piezometers at distant locations were diagnostic only of aquifer transmissivity.

Massachusetts↗