Geology Reports⌕ Search

Geology topics

Ziyan Wu

Publications and source records attributed to Ziyan Wu.

4 recordsLinked to original sources

Decoding the oxidative digestion mechanism for polystyrene nanoplastic detection in the Great Lakes using a customizable Raman spectral processing algorithm

Despite the concerns surging around nanoplastics (NPs) regarding their prevalence and bioavailability in freshwater systems, robust detection of NPs in complex environmental matrices is hindered by the lack of standardized sample pretreatment and a mechanistic understanding of oxidative digestion. Here, we systematically investigate the interaction between hydrogen peroxide (H 2 O 2 ) and polystyrene (PS) NPs during digestion in deionized (DI) water and four environmental matrices from in and around the Great Lakes Basin. To facilitate high-throughput analysis, we develop Pre_peak, a customizable Raman spectral processing algorithm that achieves >99% accuracy for both NP identification and interference rejection, allowing reliable NP quantification via pixel counting and systematic decoding of the oxidative digestion mechanisms. In DI water, varying H 2 O 2 doses from 0 to 30% has negligible effects on the recovery and Raman signal intensity of PS NPs over 24 hours of digestion. However, morphological changes and aggregation of PS NPs are observed when the H 2 O 2 dose exceeds 20%. Prolonged digestion further leads to progressive NP loss. In natural waters, the optimal dosage and digestion duration depend on matrix characteristics, including dissolved organic matter (DOM) and ion composition. This study provides mechanistic insights into NP–oxidant interactions and underscores the need for matrix-tailored digestion protocols to advance standardized NP detection in freshwater environments.

Great Lakes↗

Microplastics undergo fragmentation during pressurized membrane filtration

Low-micrometer microplastics (<10 μm) have been detected in drinking water, driving growing interest in using pressure-driven membrane filtration to remove these particles and ensure drinking water safety. However, little attention is paid to the fate of microplastics concentrated in the filtration byproduct. In this study, using well-defined polystyrene (PS) and poly(methyl methacrylate) microspheres as model particles, we observed microplastic fragmentation during nanofiltration and the subsequent release of smaller fragments. After operating for 3 h at 20 bar, 67.9 ± 8.0% of the PS spheres in the concentrate, based on particles counted in selected fields of view, were transformed into fractured particles. The characteristic Raman band signals of microplastics were significantly weakened after fragmentation, leading to detection challenges. To address this, a data processing algorithm was developed to identify PS fragments as small as 1 μm. Preliminary statistical analysis reveals that within the tested pressure range, operation time has a stronger influence on fragmentation than pressure magnitude alone and that fragmentation is further governed by the intrinsic mechanical properties of the tested model polymers. This work provides direct evidence that pressure-driven membrane processes induce microplastic fragmentation and highlights the environmental risks associated with the discharge of fragmented microplastics into the concentrate.

Environmental Science & Technology Letters↗

Regenerable membrane sensors for ultrasensitive nanoplastic quantification enabled by a data-driven Raman spectral processing algorithm

The detection of nanoplastics (NPs) in complex natural water systems is hindered by matrix interferences and limitations in current analytical techniques. This study presents Pre_seg, a Raman spectral processing algorithm integrated with regenerable anodic aluminum oxide (AAO) membrane sensors, for ultrasensitive, rapid, and quantitative NP detection at the single-particle level. The AAO membranes function as both filtration substrates and Raman sensors, reducing sample loss and contamination. Pre_seg incorporates statistically determined thresholds for signal-to-noise ratios (SNRs) and full width at half maximums (fwhms) across segmented spectral ranges, effectively minimizing noise and enhancing accuracy and sensitivity of NP detection. Pre_seg achieved 93.5% prediction accuracy of NPs and ≥90.4% rejection accuracy for non-NP entries. Mixed NPs were quantified at the lowest concentration of 0.5 μg L –1 . The robustness of Pre_seg was validated in eutrophic and oligotrophic lake matrices following oxidation digestion pretreatment to mitigate organic interferences. Furthermore, the AAO membrane sensors demonstrated stability through multiple regeneration and reuse cycles. This innovative approach advances NP detection by enabling scalable, customizable, and environmentally relevant monitoring.

Environmental Science and Technology↗

Adaptable plasmonic membrane sensors for fast and reliable detection of trace low micrometer microplastics in lake water

In freshwater environments, low-micrometer microplastics (LMMPs) have captured significant attention due to their prevalence and toxicity. Yet, rapid detection of LMMPs (1–10 μm) at the single-particle level within complex freshwater matrices remains a hurdle. We developed an adaptable plasmonic membrane sensor for fast detection of individual LMMPs in eutrophic lake waters. The plasmonic membrane sensor functions both as a membrane filter and as a sensor for LMMP collection and analysis. Among the four types of membrane sensors, polycarbonate track-etch (PCTE) membrane sensors exhibit superior imaging quality for LMMPs due to their flat and homogeneous surfaces. Besides the significantly improved imaging contrast and reduced background interferences, the Raman intensity of LMMPs is enhanced by 48% ± 25% on PCTE membrane sensors compared to unmodified membranes. The increased Raman intensities of a chemical probe with an increasing gold layer thickness and a decreasing membrane pore size suggest a surface-enhanced Raman scattering effect from the membrane sensors. The membrane sensors achieve a detection limit of 1 μg/L and an ultrafast scanning time of 0.01 s for individual LMMPs across natural eutrophic lake water. The developed membrane sensors offer an adaptable tool for the swift and reliable detection of individual LMMPs in complex environmental matrices.

Environmental Science and Technology↗