Geology ReportsSearch

Geology topics

W.L. Cranor

Publications and source records attributed to W.L. Cranor.

7 recordsLinked to original sources

Reproductive health of bass in the potomac, USA, drainage: Part 2. Seasonal occurrence of persistent and emerging organic contaminants

The seasonal occurrence of organic contaminants, many of which are potential endocrine disruptors, entering the Potomac River, USA, watershed was investigated using a two-pronged approach during the fall of 2005 and spring of 2006. Passive samplers (semipermeable membrane device and polar organic chemical integrative sampler [POCIS]) were deployed in tandem at sites above and below wastewater treatment plant discharges within the watershed. Analysis of the samplers resulted in detection of 84 of 138 targeted chemicals. The agricultural pesticides atrazine and metolachlor had the greatest seasonal changes in water concentrations, with a 3.1 - to 91 -fold increase in the spring compared with the level in the previous fall. Coinciding with the elevated concentrations of atrazine in the spring were increasing concentrations of the atrazine degradation products desethylatrazine and desisopropylatrazine in the fall following spring and summer application of the parent compound. Other targeted chemicals (organochlorine pesticides, polycyclic aromatic hydrocarbons, and organic wastewater chemicals) did not indicate seasonal changes in occurrence or concentration; however, the overall concentrations and number of chemicals present were greater at the sites downstream of wastewater treatment plant discharges. Several fragrances and flame retardants were identified in these downstream sites, which are characteristic of wastewater effluent and human activities. The bioluminescent yeast estrogen screen in vitro assay of the POCIS extracts indicated the presence of chemicals that were capable of producing an estrogenic response at all sampling sites. ?? 2009 SETA.

Environmental Toxicology and Chemistry

Semivolatile organic compounds in residential air along the Arizona - Mexico border

Concerns about indoor air quality and the potential effects on people living in these environments are increasing as more reports about the toxicities and the potential indoor air exposure levels of household-use chemicals and chemicals fromhousingandfurnishingmanufactureinairarebeingassessed. Gas chromatography/mass spectrometry was used to confirm numerous airborne contaminants obtained from the analysis of semipermeable membrane devices deployed inside of 52 homes situated along the border between Arizona and Mexico. We also describe nontarget analytes in the organochlorine pesticide fractions of 12 of these homes; this fraction is also the most likelytocontainthebroadestscopeofbioconcentratablechemicals accumulated from the indoor air. Approximately 400 individual components were identified, ranging from pesticides to a wide array of hydrocarbons, fragrances such as the musk xylenes, flavors relating to spices, aldehydes, alcohols, esters and phthalate esters, and other miscellaneous types of chemicals. The results presented in this study demonstrate unequivocally that the mixture of airborne chemicals present indoors is far more complex than previously demonstrated. ?? 2009 American Chemical Society.

Environmental Science & Technology

Uptake rate constants and partition coefficients for vapor phase organic chemicals using semipermeable membrane devices (SPMDs)

To fully utilize semipermeable membrane devices (SPMDs) as passive samplers in air monitoring, data are required to accurately estimate airborne concentrations of environmental contaminants. Limited uptake rate constants (k ua ) and no SPMD air partitioning coefficient (K sa ) existed for vapor-phase contaminants. This research was conducted to expand the existing body of kinetic data for SPMD air sampling by determining k ua and K sa for a number of airborne contaminants including the chemical classes: polycyclic aromatic hydrocarbons, organochlorine pesticides, brominated diphenyl ethers, phthalate esters, synthetic pyrethroids, and organophosphate/organosulfur pesticides. The k ua s were obtained for 48 of 50 chemicals investigated and ranged from 0.03 to 3.07??m 3 ??g -1 ??d -1 . In cases where uptake was approaching equilibrium, K sa s were approximated. K sa values (no units) were determined or estimated for 48 of the chemicals investigated and ranging from 3.84E+5 to 7.34E+7. This research utilized a test system (United States Patent 6,877,724 B1) which afforded the capability to generate and maintain constant concentrations of vapor-phase chemical mixtures. The test system and experimental design employed gave reproducible results during experimental runs spanning more than two years. This reproducibility was shown by obtaining mean k ua values (n??=??3) of anthracene and p,p???-DDE at 0.96 and 1.57??m 3 ??g -1 ??d -1 with relative standard deviations of 8.4% and 8.6% respectively.

Atmospheric Environment

Comparisons of coarse and fine versions of two carbons for reducing the bioavailabilities of sediment-bound hydrophobic organic contaminants

Coarse (whole) and finely ground Ambersorb 1500 and coarse and fine coconut charcoal were compared as to their efficiencies in scavenging organic contaminants desorbed from sediment. Aqueous slurries of a test sediment spiked (1 ppm) with p,p???-DDE (DDE), 2,2???,5,5???-tetrachlorobiphenyl (TCB), naphthalene (NAP), or phenanthrene (PHEN), and containing 1% levels of the test carbons were treated by shaking at 35 ??C while exposed to clusters of low-density polyethylene membrane (detox spiders). Controls consisted of spiked sediments and detox spiders but no added carbon of any kind and thus represented unimpeded bioavailabilities (to the spiders). After the treatments - agitation periods from 2.5 to 60 h, depending on contaminant hydrophobicity - the exposed detox spiders were analyzed. The fine carbon of either type was more effective than its coarser variant in obstructing contaminant bioavailabilities. The finer variants of both carbons obstructed the bioavailabilities of NAP and PHEN equally well as did the coarser variants of both. Whole Ambersorb 1500 and coarse coconut charcoal were similarly ineffective in intercepting TCB and DDE. Ground Ambersorb 1500 obstructed virtually all bioavailability of all four contaminants and was far more effective than fine coconut charcoal in intercepting DDE and TCB. An additional experiment compared the effectiveness of ground Ambersorb 1500 and fine coconut charcoal in obstructing the bioavailabilities from sediment of a broad array of spiked organochlorine pesticides. The performance of ground Ambersorb 1500 was again found to be superior; the bioavailable levels of each of the 27 pesticides were markedly lower in the presence of ground Ambersorb 1500 than in the presence of fine coconut charcoal.

Chemosphere

Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices

Permeability/performance reference compounds (PRCs) are analytically noninterfering organic compounds with moderate to high fugacity from semipermeable membrane devices (SPMDs) that are added to the lipid prior to membrane enclosure. Assuming that isotropic exchange kinetics (IEK) apply and that SPMD-water partition coefficients are known, measurement of PRC dissipation rate constants during SPMD field exposures and laboratory calibration studies permits the calculation of an exposure adjustment factor (EAF). In theory, PRC-derived EAF ratios reflect changes in SPMD sampling rates (relative to laboratory data) due to differences in exposure temperature, membrane biofouling, and flow velocity-turbulence at the membrane surface. Thus, the PRC approach should allow for more accurate estimates of target solute/vapor concentrations in an exposure medium. Under some exposure conditions, the impact of environmental variables on SPMD sampling rates may approach an order of magnitude. The results of this study suggest that most of the effects of temperature, facial velocity-turbulence, and biofouling on the uptake rates of analytes with a wide range of hydrophobicities can be deduced from PRCs with a much narrower range of hydrophobicities. Finally, our findings indicate that the use of PRCs permits prediction of in situ SPMD sampling rates within 2-fold of directly measured values.

Environmental Science & Technology

Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants

Semipermeable membrane devices (SPMDs) are used with increasing frequency, and throughout the world as samplers of organic contaminants. The devices can be used to detect a variety of lipophilic chemicals in water, sediment/soil, and air. SPMDs are designed to sample nonpolar, hydrophobic chemicals. The maximum concentration factor achievable for a particular chemical is proportional to its octanol–water partition coefficient. Techniques used for cleanup of SPMD extracts for targeted analytes and for general screening by full-scan mass spectrometry do not differ greatly from techniques used for extracts of other matrices. However, SPMD extracts contain potential interferences that are specific to the membrane–lipid matrix. Procedures have been developed or modified to alleviate these potential interferences. The SPMD approach has been demonstrated to be applicable to sequestering and analyzing a wide array of environmental contaminants including organochlorine pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polychlorinated dioxins and dibenzofurans, selected organophosphate pesticides and pyrethroid insecticides, and other nonpolar organic chemicals. We present herein an overview of effective procedural steps for analyzing exposed SPMDs for trace to ultra-trace levels of contaminants sequestered from environmental matrices.

Journal of Chromatography A

An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests

As an integral part of our continued development of water quality assessment approaches, we combined integrative sampling, instrumental analysis of widely occurring anthropogenic contaminants, and the application of a suite of bioindicator tests as a specific part of a broader survey of ecological conditions, species diversity, and habitat quality in the Santa Cruz River in Arizona, USA. Lipid-containing semipermeable membrane devices (SPMDs) were employed to sequester waterborne hydrophobic chemicals. Instrumental analysis and a suite of bioindicator tests were used to determine the presence and potential toxicological relevance of mixtures of bioavailable chemicals in two major water sources of the Santa Cruz River. The SPMDs were deployed at two sites; the effluent weir of the International Wastewater Treatment Plant (IWWTP) and the Nogales Wash. Both of these systems empty into the Santa Cruz River and the IWWTP effluent is a potential source of water for a constructed wetland complex. Analysis of the SPMD sample extracts revealed the presence of organochlorine pesticides (OCs), polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). The bioindicator tests demonstrated increased liver enzyme activity, perturbation of neurotransmitter systems and potential endocrine disrupting effects (vitellogenin induction) in fish exposed to the extracts. With increasing global demands on limited water resources, the approach described herein provides an assessment paradigm applicable to determining the quality of water in a broad range of aquatic systems.

Chemosphere