High nutrient pulses, tidal mixing and biological response in a small California estuary: Variability in nutrient concentrations from decadal to hourly time scales

Elkhorn Slough is a small estuary in Central California, where nutrient inputs are dominated by runoff from agricultural row crops, a golf course, and residential development. We examined the variability in nutrient concentrations from decadal to hourly time scales in Elkhorn Slough to compare forcing by physical and biological factors. Hourly data were collected using in situ nitrate analyzers and water quality data sondes, and two decades of monthly monitoring data were analyzed. Nutrient concentrations increased from the mid 1970s to 1990s as pastures and woodlands were converted to row crops and population increased in the watershed. Climatic variability was also a significant factor controlling interannual nutrient variability, with higher nutrient concentrations during wet than drought years. Elkhorn Slough has a Mediterranean climate with dry and rainy seasons. Dissolved inorganic nitrogen (DIN) concentrations were relatively low (10-70 ??mol L-1) during the dry season and high (20-160 ??mol L-1) during the rainy season. Dissolved inorganic phosphorus (DIP) concentrations showed the inverse pattern, with higher concentrations during the dry season. Pulsed runoff events were a consistent feature controlling nitrate concentrations during the rainy season. Peak nitrate concentrations lagged runoff events by 1 to 6 days. Tidal exchange with Monterey Bay was also an important process controlling nutrient concentrations, particularly near the mouth of the Slough. Biological processes had the greatest effect on nitrate concentrations during the dry season and were less important during the rainy season. While primary production was enhanced by nutrient pulses, chlorophyll a concentrations were not. We believe that the generally weak biological response compared to the strong physical forcing in Elkhorn Slough occurred because the short residence time and tidal mixing rapidly diluted nutrient pulses. ?? 2006 Elsevier Ltd. All rights reserved.

Estuarine, Coastal and Shelf Science

Development of a solenoid pumped in situ zinc analyzer for environmental monitoring

A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 μg L −1 . Precision was 5–10% relative standard deviation (R.S.D.) below 100 μg L −1 , improving to 1% R.S.D. at 1000 μg L −1 . The linear range extended from 30 to 3000 μg L −1 . In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector.

Analytica Chimica Acta

In situ osmotic analyzer for the year-long continuous determination of Fe in hydrothermal systems

A submersible osmotically pumped analyzer (Fe-OsmoAnalyzer) has been adapted for the long-term continuous high resolution monitoring of iron(II) and (III) in deep-sea hydrothermal vents. Ferrozine is used as the colorimetric reagent. The detection limit for our analyzer is 0.1??M for a 0.7cm pathlength with a linear response up to 50??M. The Fe-OsmoAnalyzer uses periodic injections of standards and blanks to self calibrate and can operate unattended for over a year collecting data every 15min. The Fe-OsmoAnalyzer was field tested during a 6 week test deployment at 900m in Monterey Bay and a year-long deployment at 1100m off the coast of Hawaii. A second year-long deployment in a low temperature hydrothermal vent on the Juan de Fuca Ridge provided high resolution continuous monitoring of Fe and was able to distinguish tidally influenced fluctuations in Fe concentrations. ?? 2002 Elsevier Science B.V. All rights reserved.