Geology ReportsSearch

Geology topics

Robert H. Mariner

Publications and source records attributed to Robert H. Mariner.

At least 37 records · Page 2Linked to original sources

Geochemistry of waters from springs, wells, and snowpack on and adjacent to Medicine Lake volcano, northern California

Chemical analyses of waters from cold springs and wells of the Medicine Lake volcano and surrounding region indicate small chloride anomalies that may be due to water-rock interaction or limited mixing with high-temperature geothermal fluids. The Fall River Springs (FRS) with a combined discharge of approximately 37 m3/s, show a negative correlation between chloride (Cl) and temperature, implying that the Cl is not derived from a high-temperature geothermal fluid. The high discharge from the FRS indicates recharge over a large geographic region. Chemical and isotopic variations in the FRS show that they contain a mixture of three distinct waters. The isotopic composition of recharge on and adjacent to the volcano are estimated from the isotopic composition of snow and precipitation amounts adjusted for evapotranspiration. Enough recharge of the required isotopic composition (-100 parts per thousand ??D) is available from a combination of the Medicine Lake caldera, the Fall River basin and the Long Bell basin to support the slightly warmer components of the FRS (32 m3/s). The cold-dilute part of the FRS (approximately 5 m3/s) may recharge in the Bear Creek basin or at lower elevations in the Fall River basin.

Geothermal Resources Council Transactions

Mantle fluids in the San Andreas fault system, California

Fluids associated with the San Andreas and companion faults n central and south-central California have high 3He/4He ratios. The lack of correlation between helium isotopes and fluid chemistry or local geology requires that fluids enter the fault system from the mantle. Mantle fluids passing through the ductile lower crust must enter the brittle fault zone at or near lithostatic pressures; estimates of fluid flux based on helium isotopes suggest that they may thus contribute directly to fault-weakening high-fluid pressures at seismogenic depths.

Science

Sulfate-water isotope geothermometry and lead isotope data for the regional geothermal system in the Twin Falls area, south-central Idaho

Sulfate-water isotope geothermometry for the geothermal system at Twin Falls, Idaho indicates aquifer-temperatures of 90?? to 106 ??C; most sites are between 90?? and 93 ??C. 206Pb/204pb and 280Pb/204Pb of individual thermal waters are principally a function of how much lead has been dissolved from the carbonate and silicate fractions of the Paleozoic limestone collected west of Grand View Peak. Although most thermal waters are recovered from Tertiary rhyolite, very little of the dissolved lead is from the rhyolite. Recharge to this system occurs in northern Nevada and the fluid moves northward in the Paleozoic limestones. The occurrence of thermal fluid in the Idavada Volcanics near and south of Twin Falls, Idaho is the result of upward movement of this fluid from the Paleozoic limestone.

Conference Paper

Hydrothermal systems of the Cascade Range, north-central Oregon

Quaternary volcanoes of the Cascade Range form a 1,200- kilometer-long arc that extends from southern British Columbia to northern California. The section of the Cascade Range volcanic arc in central Oregon is characterized by relatively high Quaternary volcanic extrusion rates and hot-spring discharge rates. Stableisotope data and measurements of hot-spring heat discharge indicate that gravity-driven thermal fluid circulation transports about 1 MW (megawatt) of heat per kilometer of arc length from the Quaternary arc into Western Cascade rocks older than about 7 Ma (millions of years before present). Inferred flow-path lengths for the Na-Ca-Cl thermal waters of the Western Cascades are 10 to 40 kilometers (km), and an average topographic gradient as large as 0.1 separates the inferred recharge areas from the hot-spring groups. Thermal-fluid residence times are probably 10 2 to 10 4 years: sulfate-water isotopic equilibrium indicates residence times of more than 10 2 years, and our interpretation of stable-isotope data implies residence times of less than 10 4 years.

Oregon

Chemical, isotopic, and dissolved gas compositions of the hot springs of the Owyhee Uplands, Malheur County, Oregon

Hot springs along the Owyhee River in southeastern Oregon between Three Forks and Lake Owyhee could be part of a north flowing regional system or a series of small separate geothermal systems Heat for the waters could be from a very young (Holocene) volcanic activity (basalt flows) of the Owyhee Uplands or the regional heat flow. The springs discharge warm to hot, dilute, slightly alkaline, sodium bicarbonate water. Chemically they are similar to the dilute thermal water at Bruneau Grand View and Twin Falls, Idaho. Maximum aquifer temperatures in the Owyhee Uplands, estimated from chemical geothermometry, are about 100°C. Dissolved helium concentrations, carbon 14 activity, and chemical and isotope data are examined fro systematic trends which would indicate a geothermal system of regional extent.

Oregon

Geothermometry and water-rock interaction in selected thermal systems in the Cascade Range and Modoc Plateau, western United States

The sulfate—water isotope geothermometer indicates higher equilibrium temperatures than the silica or cation ratio geothermometers for the Na—Cl and Na—Ca—Cl thermal waters of the Cascade Range, Oregon and the Na—SO 4 thermal waters of the Modoc Plateau, northeastern California. Sulfate concentrations in the Na—Ca—Cl waters decrease as σ 18 O values of the dissolved sulfate become more depleted; conversely, sulfate concentrations in the Na—SO 4 waters increase as σ 18 O values of the sulfate become more depleted. Calculations show that the thermal waters are theoretically saturated with respect to anhydrite (CaSO 4 ) at temperatures very close to those calculated from the sulfate—water isotope geothermometer.

Geothermics

Thermal waters along the Konocti Bay fault zone, Lake County, California: a re-evaluation

The Konocti Bay fault zone (KBFZ), initially regarded by some as a promising target for liquid-dominated geothermal systems, has been a disappointment. At least five exploratory wells were drilled in the vicinity of the KBFZ, but none were successful. Although the Na-K-Ca and Na-Li geothermometers indicate that the thermal waters discharging in the vicinity of Howard and Seigler Springs may have equilibrated at temperatures greater than 200??C, the spring temperatures and fluid discharges are low. Most thermal waters along the KBFZ contain >100 mg/l Mg. High concentrations of dissolved magnesium are usually indicative of relatively cool hydrothermal systems. Dissolution of serpentine at shallow depths may contribute dissolved silica and magnesium to rising thermal waters. Most thermal waters are saturated with respect to amorphous silica at the measured spring temperature. Silica geothermometers and mixing models are useless because the dissolved silica concentration is not controlled by the solubility of either quartz or chalcedony. Cation geothermometry indicates the possibility of a high-temperature fluid (> 200??C) only in the vicinity of Howard and Seigler Springs. However, even if the fluid temperature is as high as that indicated by the geothermometers, the permeability may be low. Deuterium and oxygen-18 values of the thermal waters indicate that they recharged locally and became enriched in oxygen-18 by exchange with rock. Diluting meteoric water and the thermal water appear to have the same deuterium value. Lack of tritium in the diluted spring waters suggest that the diluting water is old. ?? 1992.

Journal of Volcanology and Geothermal Research

Chemical, isotopic, and dissolved gas compositions of the hydrothermal system in Twin Falls and Jerome counties, Idaho

The chemical, isotopic, and gas compositions of the hydrothermal system in Twin Falls and Jerome counties, Idaho, change systematically as the water moves northward from the Idaho-Nevada boundary toward the Snake River. Sodium, chloride, fluoride, alkalinity, dissolved helium, and carbon-13 increase as calcium and carbon-14 decrease. Water-rock reactions may result in dissolution of plagioclase or volcanic glass and calcite, followed by precipitation of zeolites and clays. On the basis of carbon-14 age dating, apparent water ages range from 2,000 to more than 26,000 years; most apparent ages range from about 4,000 to 10,000 years. The older waters, north of the Snake River, are isotopically depleted in deuterium and are enriched in chloride relative to waters to the south. Thermal waters flowing northward beneath the Snake River may join a westward flow of older thermal water slightly north of the river. The direction of flow in the hydrothermal system seems to parallel the surface drainage.

Geothermal Resources Council Transactions

Geothermal segmentation of the Cascade Range in the USA

Characteristics of the crustal thermal regime of the Quaternary Cascades vary systematically along the range. Spatially congruent changes in volcanic vent distribution, volcanic extrusion rate, hydrothermal discharge rate, and regional conductive heat flow define 5 geothermal segments. These segments are, from north to south: (1) the Washington Cascades north of Mount Rainier, (2) the Cascades from Mount Rainier to Mount Hood, (3) the Oregon Cascades from south of Mount Hood to the California border, (4) northernmost California, including Mount Shasta and Medicine Lake volcano, and (5) the Lassen region of northern California. This segmentation indicates that geothermal resource potential is not uniform in the Cascade Range. Potential varies from high in parts of Oregon to low in Washington north of Mount Rainier.

Conference Paper

Heat flow and hydrothermal circulation in the Cascade Range, north-central Oregon

In north-central Oregon a large area of near-zero near-surface conductive heat flow occurs in young volcanic rocks of the Cascade Range. Recent advective heat flux measurements and a heat-budget analysis suggest that ground-water circulation sweeps sufficient heat out of areas where rocks younger than 6 Ma (million years ago) are exposed to account for the anomalously high advective and conductive heat discharge measured in older rocks at lower elevations. Earlier workers have proposed that an extensive midcrustal magmatic heat source is responsible for this anomalously high heat flow. Instead, high heat flow in the older rocks may be a relatively shallow phenomenon caused by regional ground-water flow. Any deeper anomaly may be relatively narrow, spatially variable, and essentially confined to the Quaternary (less than 2 Ma) arc. Magmatic intrusion at a rate of 9 to 33 cubic kilometers per kilometer of arc length per million years can account for the total heat flow anomaly. Deep drilling in the areas of high heat flow in the older rocks could indicate which model is more appropriate for the near-surface heat flow data.

Oregon

Geochemistry of thermal water from selected wells, Boise, Idaho

Samples of thermal water from selected wells in the Boise area were analyzed for chemical composition; stable isotopes of hydrogen, oxygen, and dissolved carbon; radioactive carbon; and dissolved-gas concentrations. Chemically, the waters are virtually identical to those of the adjacent Idaho batholith. Isotopically, the thermal waters are more depleted in deuterium and oxygen-18 than coldwater springs in the presumed recharge area. Chemical and isotopic data indicate the presence of two separate geothermal systems. Radioactive carbon and dissolved helium concentrations are interpreted to indicate recharge during the Pleistocene. Hot water in or southeast of Boise probably recharged 20,000 to 30,000 years ago, and warm water 2.5 miles northwest of Boise probably recharged at least 15,000 years ago.

Conference Paper

Isotope geochemistry of minerals and fluids from Newberry volcano, Oregon

Isotopic compositions were determined for hydrothermal quartz, calcite, and siderite from core samples of the Newberry 2 drill hole, Oregon. The ??15O values for these minerals decrease with increasing temperatures. The values indicate that these hydrothermal minerals precipitated in isotopic equilibrium with water currently present in the reservoirs. The ??18O values of quartz and calcite from the andesite and basalt flows (700-932 m) have isotopic values which require that the equilibrated water ??18O values increase slightly (- 11.3 to -9.2???) with increasing measured temperatures (150-265??C). The lithic tuffs and brecciated lava flows (300-700 m) contain widespread siderite. Calculated oxygen isotopic compositions of waters in equilibrium with siderite generally increase with increasing temperatures (76-100??C). The ??18O values of siderite probably result from precipitation in water produced by mixing various amounts of the deep hydrothermal water (- 10.5 ???) with meteoric water (- 15.5 ???) recharged within the caldera. The ??13C values of calcite and siderite decrease with increasing temperatures and show that these minerals precipitated in isotopic equilibrium with CO2 of about -8 ???. The ??18O values of weakly altered (<5% alteration of plagioclase) whole-rock samples decrease with increasing temperatures above 100??C, indicating that exchange between water and rock is kinetically controlled. The water/rock mass ratios decrease with decreasing temperatures. The ??18O values of rocks from the bottom of Newberry 2 show about 40% isotopic exchange with the reservoir water. The calculated ??18O and ??D values of bottom hole water determined from the fluid produced during the 20 hour flow test are -10.2 and -109???, respectively. The ??D value of the hydrothermal water indicates recharge from outside the caldera. ?? 1987.

Journal of Volcanology and Geothermal Research

Flow testing of the Newberry 2 research drillhole, Newberry volcano, Oregon

A 20 hour flow test of the Newberry 2 research drillhole at Newberry Volcano produced about 33,000 kilograms of fluid. The flow rate declined from about 0.8 kilograms per sec to less than 0.3 kilograms per sec during the course of the test. The mass ratio of liquid water to vapor was about 3:2 at the separator and stayed fairly constant throughout the test. The vapor phase was about half steam and half CO2 by weight. The average enthalpy of the steam/water mixture at the separator was about 1 ,200 kilojoules per kilogram. Because of the low flow rate and the large temperature gradient into the surrounding rocks, heat loss from the wellbore was high; a simple conductive model gives overall losses of about 1,200 kilojoules per kilogram of H2O produced. The actual heat loss may have been even higher due to convective effects, and it is likely that the fluid entering the bottom of the wellbore was largely or entirely steam and CO2. (Author 's abstract)

Water-Resources Investigations Report

Hydrologic and geochemical monitoring in Long Valley caldera, Mono County, California, 1982-1984

The Long Valley caldera is a potentially active volcanic area on the eastern side of the Sierra Nevada in east-central California. Hydrologic and geochemical monitoring of surface and subsurface features began in July 1982 to determine if changes were occurring in response to processes causing earthquakes and crustal deformation. Differences since 1982 in fluid chemistry of springs has been minor except at Casa Diablo, where rapid fluctuations in chemistry result from near surface boiling and mixing. Ratios of 3 He/ 4 He and 13 C/ 12 C in hot springs and fumaroles are consistent with a magnetic source for some of the carbon and helium discharged in thermal areas, and observed changes in 3 He/ 4 He between 1978 and 1984 suggest changes in the magmatic component. Significant fluctuations in hot spring discharge recorded at several sites since 1982 closely followed earthquake activity. Water levels in wells have been used as strain meters to detect rock deformation associated with magmatic and tectonic activity and to construct a water table contour map. Coseismic water level fluctuations of as much as 0.6 ft have been observed but no clear evidence of deformation caused by magmatic intrusions can be seen in the well records through 1984. Temperature profiles in wells, which can be used to delineate regionally continuous zones of lateral flow of hot water across parts of the caldera, have remained constant at all but two sites.

California

Selected data for low-temperature (less than 90 degrees C) geothermal systems in the United States; reference data for U.S. Geological Survey Circular 892

Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

Open-File Report