Geology Reports⌕ Search

Geology topics

Robert C. Trautz

Publications and source records attributed to Robert C. Trautz.

5 recordsLinked to original sources

Comparison of geochemical data obtained using four brine sampling methods at the SECARB Phase III Anthropogenic Test CO2 injection site, Citronelle Oil Field, Alabama

The chemical composition of formation water and associated gases from the lower Cretaceous Paluxy Formation was determined using four different sampling methods at a characterization well in the Citronelle Oil Field, Alabama, as part of the Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test, which is an integrated carbon capture and storage project. In this study, formation water and gas samples were obtained from well D-9-8 #2 at Citronelle using gas lift, electric submersible pump, U-tube, and a downhole vacuum sampler (VS) and subjected to both field and laboratory analyses. Field chemical analyses included electrical conductivity, dissolved sulfide concentration, alkalinity, and pH; laboratory analyses included major, minor and trace elements, dissolved carbon, volatile fatty acids, free and dissolved gas species. The formation water obtained from this well is a Na–Ca–Cl-type brine with a salinity of about 200,000 mg/L total dissolved solids. Differences were evident between sampling methodologies, particularly in pH, Fe and alkalinity. There was little gas in samples, and gas composition results were strongly influenced by sampling methods. The results of the comparison demonstrate the difficulty and importance of preserving volatile analytes in samples, with the VS and U-tube system performing most favorably in this aspect.

International Journal of Coal Geology↗

Geochemical modeling of changes in shallow groundwater chemistry observed during the MSU-ZERT CO2 injection experiment

A field experiment involving the release of carbon dioxide (CO 2 ) into a shallow aquifer was conducted near Bozeman, Montana, during the summer of 2008, to investigate the potential groundwater quality impacts in the case of leakage of CO 2 from deep geological storage. As an essential part of the Montana State University Zero Emission Research and Technology (MSU-ZERT) field program, food-grade CO 2 was injected over a 30 day period into a horizontal perforated pipe a few feet below the water table of a shallow aquifer. The impact of elevated CO 2 concentrations on groundwater quality was investigated by analyzing water samples taken before, during, and following CO 2 injection, from observation wells located in the vicinity of the injection pipe, and from two distant monitoring wells. Field measurements and laboratory analyses showed rapid and systematic changes in pH, alkalinity, and conductance, as well as increases in the aqueous concentrations of naturally occurring major and trace element species. The geochemical data were evaluated using principal component analysis (PCA) to (1) understand potential correlations between aqueous species, and (2) to identify minerals controlling the chemical composition of the groundwater prior to CO 2 injection. These evaluations were used to assess possible geochemical processes responsible for the observed increases in the concentrations of dissolved constituents, and to simulate these processes using a multicomponent reaction path model. Reasonable agreement between observed and modeled data suggests that (1) calcite dissolution was the primary pH buffer, yielding increased Ca +2 concentrations in the groundwater, (2) increases in the concentrations of most major and trace metal cations except Fe could be a result of Ca +2 -driven exchange reactions, (3) the release of anions from adsorption sites due to competitive adsorption of carbonate could explain the observed trends of most anions, and (4) the dissolution of reactive Fe minerals (presumed ferrihydrite and fougerite, from thermodynamic analyses) could explain increases in total Fe concentration. Highlights ► Because the possibility of CO 2 leakage cannot be completely ruled out, the potential impact of CO 2 intrusion on the quality of fresh water aquifers overlying CO 2 storage sites needs to be investigated. ► Geochemical data from a field experiment involving the release of carbon dioxide (CO 2 ) into a shallow aquifer were evaluated. ► Geochemical model used to assess possible geochemical processes responsible for the observed increases in the concentrations of dissolved constituents. ► Reasonable agreement between observed and modeled data suggests that increases in the concentrations of most major and trace metal cations except Fe could be a result of Ca +2 -driven exchange reactions and the release of anions from adsorption sites due to competitive adsorption of carbonate could explain the observed trends of most anions.

Montana↗

Changes in the chemistry of shallow groundwater related to the 2008 injection of CO2 at the ZERT field site, Bozeman, Montana

Approximately 300 kg/day of food-grade CO 2 was injected through a perforated pipe placed horizontally 2–2.3 m deep during July 9–August 7, 2008 at the MSU-ZERT field test to evaluate atmospheric and near-surface monitoring and detection techniques applicable to the subsurface storage and potential leakage of CO 2 . As part of this multidisciplinary research project, 80 samples of water were collected from 10 shallow monitoring wells (1.5 or 3.0 m deep) installed 1–6 m from the injection pipe, at the southwestern end of the slotted section (zone VI), and from two distant monitoring wells. The samples were collected before, during, and following CO 2 injection. The main objective of study was to investigate changes in the concentrations of major, minor, and trace inorganic and organic compounds during and following CO 2 injection. The ultimate goals were (1) to better understand the potential of groundwater quality impacts related to CO 2 leakage from deep storage operations, (2) to develop geochemical tools that could provide early detection of CO 2 intrusion into underground sources of drinking water (USDW), and (3) to test the predictive capabilities of geochemical codes against field data. Field determinations showed rapid and systematic changes in pH (7.0–5.6), alkalinity (400–1,330 mg/l as HCO 3 ), and electrical conductance (600–1,800 μS/cm) following CO 2 injection in samples collected from the 1.5 m-deep wells. Laboratory results show major increases in the concentrations of Ca (90–240 mg/l), Mg (25–70 mg/l), Fe (5–1,200 ppb), and Mn (5–1,400 ppb) following CO 2 injection. These chemical changes could provide early detection of CO 2 leakage into shallow groundwater from deep storage operations. Dissolution of observed carbonate minerals and desorption-ion exchange resulting from lowered pH values following CO 2 injection are the likely geochemical processes responsible for the observed increases in the concentrations of solutes; concentrations generally decreased temporarily following four significant precipitation events. The DOC values obtained are 5 ± 2 mg/l, and the variations do not correlate with CO 2 injection. CO 2 injection, however, is responsible for detection of BTEX (e.g. benzene, 0–0.8 ppb), mobilization of metals, the lowered pH values, and increases in the concentrations of other solutes in groundwater. The trace metal and BTEX concentrations are all significantly below the maximum contaminant levels (MCLs). Sequential leaching of core samples is being carried out to investigate the source of metals and other solutes.

Montana↗

Measuring permanence of CO 2 storage in saline formations: The Frio experiment

If CO 2 released from fossil fuel during energy production is returned to the subsurface, will it be retained for periods of time significant enough to benefit the atmosphere? Can trapping be assured in saline formations where there is no history of hydrocarbon accumulation? The Frio experiment in Texas was undertaken to provide answers to these questions. One thousand six hundred metric tons of CO 2 were injected into the Frio Formation, which underlies large areas of the United States Gulf Coast. Reservoir characterization and numerical modeling were used to design the experiment, as well as to interpret the results through history matching. Closely spaced measurements in space and time were collected to observe the evolution of immiscible and dissolved CO 2 during and after injection. The high-permeability, steeply dipping sandstone allowed updip flow of supercritical CO 2 as a result of the density contrast with formation brine and absence of a local structural trap. The front of the CO 2 plume moved more quickly than had been modeled. By the end of the 10-day injection, however, the plume geometry in the plane of the observation and injection wells had thickened to a distribution similar to the modeled distribution. As expected, CO 2 dissolved rapidly into brine, causing pH to fall and calcite and metals to be dissolved. Postinjection measurements, including time-lapse vertical seismic profiling transects along selected azimuths, cross-well seismic topography, and saturation logs, show that CO 2 migration under gravity slowed greatly 2 months after injection, matching model predictions that significant CO 2 is trapped as relative permeability decreases.

Environmental Geosciences↗

The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO 2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO 2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO 2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO 2 . A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO 2 . The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO 2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

Journal of Geophysical Research Solid Earth↗