Geology Reports⌕ Search

Geology topics

Ray H. Wiedmeyer

Publications and source records attributed to Ray H. Wiedmeyer.

7 recordsLinked to original sources

Influence of mining-related activities on concentrations of metals in water and sediment from streams of the Black Hills, South Dakota

Water and sediment samples were collected from streams in Spearfish Creek, Whitewood Creek, and Bear Butte Creek watersheds in the Black Hills, SD, an area impacted by gold mining operations. Arsenic concentrations that exceeded the U.S. Environmental Protection Agency's Maximum Concentration Limit of 50 μg/L for drinking water were found in water from Annie Creek, a tributary of Spearfish Creek, and from Whitewood Creek. Gold Run, a tributary of Whitewood Creek, and Annie Creek contained Se concentrations in water that exceeded the EPA Ecotox threshold of 5 μg/L and were classified as a high hazard for Se accumulation from water into the planktonic food chain and for resultant toxicity to fish and aquatic birds. Concentrations of As, Cd, Cu, Hg, Ni, Pb, and Zn in sediment exceeded EPA Ecotox thresholds in one or more of the watersheds suggesting potential adverse ecological effects. Sediment from Rubicon Creek, a tributary of Spearfish Creek, contained Se concentrations high enough (4.0 μg/g) to be a moderate hazard for accumulation from sediments into the benthic food chain, with resultant dietary toxicity to fish and aquatic birds. These results are discussed in light of historical mining activities and recent clean-up and reclamation efforts. Based on the results and comparisons to Ecotox tresholds, further studies of ecological effects are warranted.

Archives of Environmental Contamination and Toxico↗

A lead isotope distribution study in swine tissue using ICP-MS

In the United States lead is an ubiquitous environmental pollutant that is a serious human health hazard, especially for women of childbearing age, developing fetuses, and young children. Information concerning the uptake and distribution of lead to maternal and fetal tissues during pregnancy is poorly documented. A study was designed using domestic swine and lead isotope enrichment methodology to focus on maternal absorption and distribution of lead into bone and soft tissues, including the fetal compartment, under varying conditions of oral lead exposure and during altered physiological states (pregnant vs unbred). Total lead levels and Pb207/Pb206 ratios in bone (femur and vertebra), blood, and soft tissues (liver, kidney, brain) were determined by ICP-MS. Lead in fetal tissues derived from maternal bone could be differentiated from that derived from exogenous dosing. Unbred swine absorbed much less lead than pregnant females receiving the same dose. The accuracy and precision of ICP-MS at the instrumental level and for the entire method (sample collection, digestion, and analysis) were evaluated for both Pb207/Pb206 ratios and total lead. Several changes were suggested in method design to improve both instrumental and total method precision.

Atomic Spectroscopy↗

The CETAC ADX-500 Autodiluter System: A Study of Dilution Performance with the ELAN 6000 ICP-MS and ELAN Software

The CETAC ADX-500 autodiluter system was tested with ELAN?? v 2.1 software and the ELAN 6000 ICP-MS instrument to determine on-line automated dilution performance during analysis of standard solutions containing nine analytes representative of the mass spectral range (mass 9 to mass 238). Two or more dilution schemes were tested for each of 5 test tube designs. Dilution performance was determined by comparison of analyte concentration means of diluted and non-diluted standards. Accurate dilutions resulted with one syringe pump addition of diluent in small diameter round-bottomed (13 mm OD) or conical-tipped (18 mm OD) tubes and one or more syringe pump additions in large diameter (28 mm OD) conical-tipped tubes. Inadequate dilution mixing which produced high analyte concentration means was observed for all dilutions conducted in flat-bottomed tubes, and for dilutions requiring multiple syringe additions of diluent in small diameter round-bottomed and conical tipped tubes. Effective mixing of diluted solutions was found to depend largely upon tube diameter and liquid depth: smaller tube diameters and greater liquid depth resulted in ineffective mixing, whereas greater tube diameter and shallower liquid depth facilitated effective mixing. Two design changes for the autodiluter were suggested that would allow effective mixing to occur using any dilution scheme and tube design.

Atomic Spectroscopy↗

A table of polyatomic interferences in ICP-MS

Spectroscopic interferences are probably the largest class of interferences in ICP-MS and are caused by atomic or molecular ions that have the same mass-to-charge as analytes of interest. Current ICP-MS instrumental software corrects for all known atomic “isobaric” interferences, or those caused by overlapping isotopes of different elements, but does not correct for most polyatomic interferences. Such interferences are caused by polyatomic ions that are formed from precursors having numerous sources, such as the sample matrix, reagents used for preparation, plasma gases, and entrained atmospheric gases.

Atomic Spectroscopy↗

The determination of Metals in sediment pore waters and in 1N HCl-extracted sediments by ICP-MS

Concentrations of metals in sediment interstitial water (pore water) and those extractable from sediment with weak acids can provide important information about the bioavailability and toxicological effects of such contaminants. The highly variable nature of metal concentrations in these matrices requires instrumentation with the detection limit capability of graphite furnace atomic absorption and the wide dynamic linear range capability of ICP-OES. These criteria are satisfied with ICP-MS instrumentation. We investigated the performance of ICP-MS in the determination of certain metals from these matrices. The results for three metals were compared to those determined by graphite furnace atomic absorption spectroscopy. It was concluded that ICP-MS was an excellent instrumental approach for the determination of metals in these matrices.

Atomic Spectroscopy↗

Communications: Blood chemistry of laboratory-reared Golden trout

Golden trout Oncorhynchus aguabonita obtained from a wild stock as fertilized eggs were reared in the laboratory for 21 months. The laboratory-reared golden trout in our study reached sexual maturity earlier and grew more rapidly than wild golden trout do (according to the scientific literature). Male fish averaged 35.6 cm in total length and 426 g in weight, and females averaged 36.2 cm and 487 g. All golden trout were sexually mature when used for hematological analysis. The hematological profile (hematocrit, red blood cells, white blood cells, and thrombocytes) of golden trout was similar to that reported elsewhere for other trout species. Male and female golden trout did not have significantly different thrombocyte counts; however, the immobilization treatment used on the fish (anesthesia versus a blow to the head) resulted in significant treatment differences in thrombocyte numbers and interaction effect of sex in treatment for hematocrits. Gravid female golden trout had significantly higher plasma protein and calcium levels than did males. The ionic compositions of plasma (sodium, potassium, calcium, magnesium, copper, zinc, iron, and chloride) and gallbladder bile (calcium and chloride) were similar to those reported for other salmonids.

Journal of Aquatic Animal Health↗