Geology ReportsSearch

Geology topics

R. L. Miller

Publications and source records attributed to R. L. Miller.

At least 37 records · Page 2Linked to original sources

Modified level II streambed-scour analysis for structure I-64-83-5678 crossing Stinking Fork in Crawford County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sediment transport data are evaluated to calculate the depth of scour that may result when a given discharge is routed through a bridge opening. The results of the modified Level II analysis for structure 1-64-83-5678 on Interstate 64 crossing Stinking Fork in Crawford County, Indiana, are presented. The site is at the town of West Fork in the southwestern part of Crawford County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 9.1 feet for the modeled discharge of 9,070 cubic feet per second and approximately 10.8 feet for the modeled discharge of 10,950 cubic feet per second.

Indianda

Modified level II streambed-scour analysis for structure I-65-118-4838 crossing Crooked Creek in Marion County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sedimenttransport data are evaluated to calculate the depth of scour that may result when a given discharge is routed through a bridge opening. The results of the modified Level II analysis for structure 1-65-118-4838 on Interstate 65 crossing Crooked Creek in Marion County, Indiana, are presented. The site is in the city of Indianapolis in the central part of Marion County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 8.3 feet for the modeled discharge of 7,000 cubic feet per second and approximately 9.2 feet for the modeled discharge of 9,870 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-69-64-4767 crossing Tippey Ditch in Grant County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sediment transport data are evaluated to calculate the depth of scour that may result when a given discharge is routed through a bridge opening. The results of the modified Level II analysis for structure 1-69-64-4767 on Interstate 69 crossing Tippey Ditch in Grant County, Indiana, are presented. The site is near the town of Van Buren in the northeastern part of Grant County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 11.9 feet for the modeled discharge of 2,000 cubic feet per second and approximately 19.8 feet for the modeled discharge of 3,400 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-64-108-5658 crossing Indian Creek in Harrison County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sedient-transport data are evaluated to calculate the depth of scour that may result when given discharge is routed through a bridge opening. the results of the modified Levell II analysis for structure I-64-108-5658 on Interstate 64 crossing Indian Creek in Harrison County, Indiana, are presented. The site is near the town of Corydon in the central part of Harrison County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 6.6 feet for the modeled discharge of 26,000 cubic feet per second and approximately 8.0 feet for the modeled discharge of 34,000 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-70-60-5180 crossing Branch of McCracken Creek in Hendricks County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sediment transport data are evaluated to calculate the depth of scour that may result when a given discharge is routed through a bridge opening. The results of the modified Level II analysis for structure 1-70-60-5180 on Interstate 70 crossing Branch of McCracken Creek in Hendricks County, Indiana, are presented. The site is near the town of Center Valley in the south-central part of Hendricks County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 12.4 feet for the modeled discharge of 1,200 cubic feet per second and approximately 24.8 feet for the modeled discharge of 2,040 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-74-32-4946 crossing Sugar Creek in Montgomery County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sedient-transport data are evaluated to calculate the depth of scour that may result when given discharge is routed through a bridge opening. The results of the modified Levell II analysis for structure I-74-32-4946 on Interstate 74 crossing Sugar Creek in Montgomery County, Indiana are presented. The site is near the town of Crawfordsville in the central part of Montgomery County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 13.0 feet for the modeled discharge of 3,000 cubic feet per second and approximately 15.1 feet for the modeled discharge of 41,900 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-465-131-5256 crossing Williams Creek in Hamilton County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sediment transport data are evaluated to calculate the depth of scour that may result when a given discharge is routed through a bridge opening. The results of the modified Level II analysis for structure 1-465-131-5256 on Interstate 465 crossing Williams Creek in Hamilton County, Indiana, are presented. The site is near the city of Indianapolis and is in the southwestern part of Hamilton County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 6.5 feet for the modeled discharge of 4,300 cubic feet per second and approximately 9.8 feet for the modeled discharge of 7,310 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-164-7-6974 crossing Schlensker Ditch in Vanderburgh County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sedient-transport data are evaluated to calculate the depth of scour that may result when given discharge is routed through a bridge opening. the results of the modified Levell II analysis for structure I-674-7-6974 on Interstate 164 crossing Schlensker Ditch in Vanderburgh County, Indiana, are presented. The site is near the town of Daylight in the northwestern part of Vanderburgh County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 176 feet for the modeled discharge of 2,100 cubic feet per second and approximately 33.4 feet for the modeled discharge of 2,940 cubic feet per second.

Indiana

Modified level II streambed-scour analysis for structure I-275-0-5639 crossing the Ohio River in Dearborn County, Indiana

Level II scour evaluations follow a process in which hydrologic, hydraulic, and sedient-transport data are evaluated to calculate the depth of scour that may result when given discharge is routed through a bridge opening. the results of the modified Levell II analysis for structure I-275-0-5639 on Interstate 275 crossing the Ohio River in Dearborn County, Indiana, are presented. The site is near the town of Lawrenceburg in the southeastern part of Dearborn County. Scour depths were computed with the Water Surface PROfile model, version V050196, which incorporates the scour-calculation procedures outlined in Hydraulic Engineering Circular No. 18. Total scour depths at the piers were approximately 35.6 feet for the modeled discharge of 760,000 cubic feet per second and approximately 35.7 feet for the modeled discharge of 890,000 cubic feet per second.

Indiana