Hydrology of the Texas Gulf Coast aquifer systems
Explore the source record for details and available documents.
Geology topics
Publications and source records attributed to Paul D. Ryder.
Explore the source record for details and available documents.
A complex, multilayered ground-water flow system exists in the Coastal Plain sediments of Texas. The Tertiary and Quaternary clastic deposits have an areal extent of 114,000 square miles onshore and in the Gulf of Mexico. Two distinct aquifer systems are recognized within the sediments, which range in thickness from a few feet to more than 12,000 feet The older system--the Texas coastal uplands aquifer system-consists of four aquifers and two confining units in the Claiborne and Wilcox Groups. It is underlain by the practically impermeable Midway confining unit or by the top of the geopressured zone. It is overlain by the nearly impermeable Vicksburg-Jackson confining unit, which separates it from the younger coastal lowlands aquifer system. The coastal lowlands aquifer system consists of five permeable zones and two confining units that range in age from Oligocene to Holocene. The hydrogeologic units of both systems are exposed in bands that parallel the coastline. The units dip and thicken toward the Gulf. Quality of water in the aquifer systems is highly variable, with dissolved solids ranging from less than 500 to 150,000 milligrams per liter. Substantial withdrawal from the aquifer systems began in the early 1900's and increased nearly continuously into the 1970's. The increase in withdrawal was relatively rapid from about 1940 to 1970. Adverse hydrologic effects, such as saltwater encroachment in coastal areas, land-surface subsidence in the Houston-Galveston area, and long-term dewatering in the Whiter Garden area, were among some of the factors that caused pumping increases to slow or to cease in the 1970's and 1980's. Ground-water withdrawals in the study area in 1980 were about 1.7 billion gallons per day. Nearly all of the withdrawal was from four units: Permeable zones A, B, and C of Miocene age and younger, and the lower Claiborae-upper Wilcox aquifer. Ground-water levels have declined hundreds of feet in the intensively pumped areas of Houston-Galveston, Kingsville, Winter Garden, and Lufkin-Nacogdoches. Water-level declines have caused inelastic compaction of clays which, in turn, has resulted in land-surface subsidence of more than one foot in an area of about 2,000 square miles. Maximum subsidence of nearly 10 feet occurs in the Pasadena area east of Houston. A three-dimensional, variable-density digital model was developed to simulate predevelopment and transient flow in the aquifer systems. The modeled area is larger than the study area, and includes adjacent parts of Louisiana and Mexico. The transient model calibration period was from 1910 (predevelopment) to 1982. Model-generated head distributions, water-level hydrographs, and land-surface subsidence were matched to measured data in selected, intensively pumped areas. For the study area, mean horizontal hydraulic conductivity in the calibrated model ranges from 10 feet per day for the middle Wilcox aquifer to 25 feet per day for permeable zone A. Mean transmissivity ranges from about 4,600 feet squared per day for the middle Claiborne aquifer to about 10,400 feet squared per day for permeable zone D. Mean vertical hydraulic conductivity ranges from 1.1x10 -5 feet per day for the Vicksburg-Jackson confining unit, to 3.8x10 -3 feet per day for permeable zone A. Mean values of calibrated storage coefficient range from 52x10 -4 for the middle Claiborne aquifer to 1.7x10 -3 for the middle Wilcox aquifer and permeable zone C. Calibrated inelastic specific storage values for clay beds in permeable zones A, B, and C in the Houston-Galveston area are 8.5x10 -5 , 8.0x10 -5 , and 8.0x10 -6 feet -1 , respectively. These values are 85, 80, and 8 times greater than the estimated elastic specific storage value for the clays in permeable zones A, B, and C, respectively. Recharge rates were mapped for predevelopment conditions as determined from a steady-state model calibration. A maximum rate of 3 inches per year was simulated in small areas, and the average rate for the study area was 034 inch per year. Total simulated recharge was 85 million cubic feet per day in the outcrop area. Recharge was equal to discharge in outcrop areas (79 million cubic feet per day) plus net lateral flow out of the study area (6 million cubic feet per day). Rates of inflow and outflow to the ground-water system have nearly tripled from predevelopment to 1982 (85 to 276 million cubic feet per day) based on model simulation. Withdrawal of 231 million cubic feet per day was supplied principally by an increase in outcrop recharge and, to a lesser extent, from a decrease in natural discharge and release of water from storage in aquifers and compacting clay beds. The average simulated 1982 recharge rate for the study area was 0.52 inch per year, with a maximum simulated rate of 6 inches per year in Jackson and Wharton Counties. Because withdrawal has caused problems such as saltwater intrusion, land-surface subsidence, and aquifer dewatering, the Texas Department of Water Resources has projected that ground-water use will decline substantially in most of the study area by the year 2030. Some areas remain favorable for development of additional ground-water supplies. Pumping from older units that are farther inland and in areas where potential recharge is greater will minimize adverse hydrologic effects.
A multilayered ground-water flow system exists in the Coastal Plain sediments of Texas. The Tertiary and Quaternary clastic deposits have an area! extent of 128,000 square miles onshore and in the Gulf of Mexico. Two distinct aquifer systems are recognized for the sediments, which range in thickness from a few feet to more than 12,000 feet. The older system the Texas coastal uplands aquifer system consists of four aquifers and two confining units in the Wilcox and Claiborne Groups. It is bounded from below by the practically impermeable Midway confining unit or by the top of the geopressured zone. It is bounded from above by the poorly permeable Vicksburg-Jackson confining unit, which separates it from the younger coastal lowlands aquifer system. The coastal lowlands aquifer system consists of five permeable zones and two confining units that range in age from Oligocene to Holocene. The hydrogeologic units of both systems are exposed in bands that parallel the coastline. The units dip and thicken toward the Gulf. Quality of water in the aquifer systems varies greatly, with dissolved solids ranging from a few hundred to more than 200,000 milligrams per liter. A three-dimensional, variable-density digital model was developed to simulate predevelopment flow in the aquifer systems, for which steady-state conditions were assumed. Horizontal hydraulic conductivities of the aquifers and permeable zones in the calibrated model range from 15 feet per day for the middle Wilcox aquifer, to 170 feet per day for the Holocene-upper Pleistocene aquifer. Vertical hydraulic conductivities range from 1 x 10 -5 foot per day for the Vicksburg-Jackson confining unit, to 1 x 10 -2 foot per day for four of the aquifers and permeable zones. The simulated values of transmissivity and leakance are functions of the percent of sand that is present in each model grid block. There is a large range in precipitation across the study area, from about 21 inches per year in the west to about 56 inches per year in the east. Eastward from a line through Corpus Christi and San Antonio, average annual precipitation ranges from about 30 to about 56 inches. A few inches per year reaches the saturated zone in topographically high areas and is discharged in low areas as evapotranspiration, seepage, springflow, and stream base flow. A smaller amount of water flows through the aquifers and permeable zones downdip from the outcrop areas. This flow results in upward or downward leakage into adjacent hydrogeologic units, but is generally upward into overlying units. Westward from the line through Corpus Christi and San Antonio, average annual precipitation ranges from about 30 to about 21 inches. The general pattern of flow in the aquifers and permeable zones is similar to that in the east, but rates of flow are somewhat smaller. In contrast to the east, ground-water discharge in the west is generally not visible. Evapotranspiration is the main mechanism for ground-water discharge, with most ground water being discharged through evapotranspiration by phreatophytes. Simulated discharge and recharge rates in the combined outcrop areas of all units do not exceed 6 inches per year. The large rates occur in small, local topographically low and high areas. The average discharge rate simulated in the outcrops of the units is 0.45 inch per year. The recharge area is considerably smaller than the discharge area, and the average recharge rate over this smaller area is 0.74 inch per year. Total simulated recharge in the outcrop areas is 269 million cubic feet per day, which is offset by an equal amount of discharge in the outcrop areas. The smallest rates of leakage are across the Vicksburg-Jackson confining unit, with downward and upward rates of less than one million cubic feet per day. The greatest rate of leakage is 47 million cubic feet per day upward into the Holocene-upper Pleistocene permeable zone.
The water table in the surficial aquifer and the potentiometric surface of the Floridan aquifer in a 1,200 square-mile area in west-central Florida are mapped semiannually by the U.S. Geological Survey. Maps are prepared on the basis of water levels measured in wells each May to coincide with seasonal low levels; and in September, when levels are high. The mapped area for this report contains nine producing wells fields which supplied 76.2 million gallons on September 21, 1977, to municipalities in the Tampa Bay area. The effect of localized withdrawal of groundwater from the Floridan aquifer is shown on the maps as cones of depression in both the potentiometric surface and water table. In September, water levels in observation wells in the Floridan aquifer were above those measured in May. These increases ranged from about 1 foot at the Eldridge-Wilde well field to about 25 feet at the Sun City well field. (Woodard-USGS)
Explore the source record for details and available documents.
The water table in the surficial aquifer and the potentiometric surface of the Florida aquifer in a 1200 square-mile area in west-central Florida are mapped semiannually by the U. S. Geological Survey. Maps are prepared on the basis of water levels measured in wells each May to coincide with seasonal low levels, and in September, when levels are high. The mapped area contains nine producing well fields which supplied 67.2 million gallons on September 8, 1976, to municipalities along the Gulf Coast. The water is from the Floridan aquifer, the major aquifer in Florida. The effect of localized withdrawal of ground water is shown on the maps as cones of depression in both the potentiometric and water-table surfaces. The September 1976 maps show the seasonal rise in water levels from the low levels of the previous May.
The coastal parts of Pasco, Pinellas and Hillsborough are undergoing extensive urban development. The Floridan aquifer is the area 's principal water supply. Potentiometric and water-table maps were prepared in order to determine the effect of groundwater withdrawals in selected well fields in west-central Florida. These maps were prepared in May 1977 to capture the annual low-water-level period. Declines in the potentiometric surface ranged from 3 feet in the Starkey well field to 25 feet in the Sun City well field. (Woodard-USGS)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.