Landsat surface product validation instrumentation: The BigMAC exercise

Users of Earth remotely sensed optical imagery are increasingly demanding a surface reflectance or surface temperature product instead of the top-of-atmosphere products that have been produced historically. Validating the accuracy of surface products remains a difficult task since it involves assessment across a range of atmospheric profiles, as well as many different land surface types. Thus, standard approaches from the satellite calibration community do not apply and new technologies need to be developed. The Big Multi-Agency Campaign (BigMAC) was developed to assess current technologies that might be used for validation of surface products derived from satellite imagery, with emphasis on Landsat. Conducted in August, 2021, in Brookings, SD, USA, a variety of measurement technologies were fielded and assessed for accuracy, precision, and deployability. Each technology exhibited its strengths and weaknesses. Handheld spectroradiometers are capable of surface reflectance measurements with accuracies in the 0.01 - 0.02 absolute reflectance units, but are expensive to deploy. Unmanned Aircraft System (UAS)-based radiometers have the potential of making measurements with similar accuracy, but are also difficult to deploy. Mirror-based empirical line methods showed improving accuracy potential, but deployment also remains an issue. However, there are inexpensive radiometers designed for long-term autonomous use that exhibited good accuracy and precision, as well as being easy to deploy. Thermal measurement technologies showed accuracy potential in the 1 - 2K range, and some easily deployable instruments are available. Results from BigMAC indicate there are technologies available today to begin making operational surface reflectance/temperature measurements and strong potential for improvements in the future.

Sensors

Landsat-8 on-orbit and Landsat-9 pre-launch sensor radiometric characterization

Landsat-8 has been operating on-orbit for 5+ years. Its two sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), are continuing to produce high quality data. The OLI has been radiometrically stable at the better than 0.3% level on a band average basis for all but the shortest wavelength (443 nm) band, which has degraded about 1.3% since launch. All on-board calibration devices continue to perform well and consistently. No gaps in across track coverage exist as 100% operability of the detectors is maintained. The variability over time of detector responsivity within a band relative to the average is better than 0.05% (1 sigma), though there are occasional detectors that jump up to 1.5% in response in the Short-Wave InfraRed (SWIR) bands. Signal-to-Noise performance continues at 2-3x better than requirements, with a small degradation in the 443 nm band commensurate with the loss in sensitivity. Pre-launch error analysis, combined with the stability of the OLI indicates that the absolute reflectance calibration uncertainty is better than 3%; comparisons to ground measurements and comparisons to other sensors are consistent with this. The Landsat-8 TIRS is similarly radiometrically stable, showing changes of at most 0.3% over the mission. The uncertainty in the absolute calibration as well as the detector to detector variability are largely driven by the stray light response of TIRS. The current processing corrects most of the stray light effects, resulting in absolute uncertainties of ~1% and reduced striping. Efforts continue to further reduce the striping. Noise equivalent delta temperature is about 50 mK at typical temperatures and 100% detector operability is maintained. Landsat-9 is currently under development with a launch no earlier than December 2020. The nearly identical OLI-2 and upgraded TIRS-2 sensors have completed integration and are in the process of instrument level performance characterization including spectral, spatial, radiometric and geometric testing. Component and assembly level measurements of the OLI-2, which include spectral response, radiometric response and stray light indicate comparable performance to OLI. The first functional tests occurred in July 2018 and spatial performance testing in vacuum is scheduled for August 2018. Similarly, for TIRS-2, partially integrated instrument level testing indicated spectral and spatial responses comparable to TIRS, with stray light reduced by approximately an order of magnitude from TIRS.

Conference Paper

Landsat-8 TIRS thermal radiometric calibration status

The Thermal Infrared Sensor (TIRS) instrument is the thermal-band imager on the Landsat-8 platform. The initial onorbit calibration estimates of the two TIRS spectral bands indicated large average radiometric calibration errors, -0.29 and -0.51 W/m 2 sr μm or -2.1K and -4.4K at 300K in Bands 10 and 11, respectively, as well as high variability in the errors, 0.87K and 1.67K (1-σ), respectively. The average error was corrected in operational processing in January 2014, though, this adjustment did not improve the variability. The source of the variability was determined to be stray light from far outside the field of view of the telescope. An algorithm for modeling the stray light effect was developed and implemented in the Landsat-8 processing system in February 2017. The new process has improved the overall calibration of the two TIRS bands, reducing the residual variability in the calibration from 0.87K to 0.51K at 300K for Band 10 and from 1.67K to 0.84K at 300K for Band 11. There are residual average lifetime bias errors in each band: 0.04 W/m 2 sr μm (0.30K) and -0.04 W/m 2 sr μm (-0.29K), for Bands 10 and 11, respectively.

Conference Paper