Geology ReportsSearch

Geology topics

Nicolas Buer

Publications and source records attributed to Nicolas Buer.

5 recordsLinked to original sources

Subsurface temperature properties for three types of permeable pavements in cold weather climates and implications for deicer reduction

Permeable pavement has been shown to be an effective urban stormwater management tool although much is still unknown about freeze-thaw responses and the implications for deicer reduction in cold weather climates. Temperature data from the subsurface of three permeable pavement types—interlocking concrete pavers (PICP), concrete (PC), and asphalt (PA)—were collected over a seven-year period and evaluated. Temperature profiles of all pavements indicate favorable conditions to allow infiltration during winter rain and melting events, with subsurface temperatures remaining above freezing even when air temperatures were below freezing. Data show that PICP surpassed PC and PA with fewer days below freezing, higher temperatures on melt days, slower freeze and faster thaw times, and less penetration of freezing temperatures at depth.

Water

Assessment of restorative maintenance practices on the infiltration capacity of permeable pavement

Permeable pavement has the potential to be an effective tool in managing stormwater runoff through retention of sediment and other contaminants associated with urban development. The infiltration capacity of permeable pavement declines as more sediment is captured, thereby reducing its ability to treat runoff. Regular restorative maintenance practices can alleviate this issue and prolong the useful life and benefits of the system. Maintenance practices used to restore the infiltration capacity of permeable pavement were evaluated on three surfaces: Permeable interlocking concrete pavers (PICP), pervious concrete (PC), and porous asphalt (PA). Each of the three test plots received a similar volume of runoff and sediment load from an adjacent, impervious asphalt parking lot. Six different maintenance practices were evaluated over a four-year period: Hand-held pressure washer and vacuum, leaf blower and push broom, vacuum-assisted street cleaner, manual disturbance of PICP aggregate, pressure washing and vacuuming, and compressed air and vacuuming. Of the six practices tested, five were completed on PICP, four on PC, and two on PA. Nearly all forms of maintenance resulted in increased average surface infiltration rates. Increases ranged from 94% to 1703% for PICP, 5% to 169% for PC, and 16% to 40% for PA. Disruption of the aggregate between the joints of PICP, whether by simple hand tools or sophisticated machinery, resulted in significant (p ≤ 0.05) gains in infiltration capacity. Sediment penetrated into the solid matrix of the PC and PA, making maintenance practices using a high-pressure wash followed by high-suction vacuum the most effective for these permeable pavement types. In all instances, when the same maintenance practice was done on multiple surfaces, PICP showed the greatest recovery in infiltration capacity.

Wisconsin

Stormwater-quality performance of line permeable pavement systems

Three permeable pavements were evaluated for their ability to improve the quality of stormwater runoff over a 22-month period in Madison, Wisconsin. Using a lined system with no internal water storage, permeable interlocking concrete pavers (PICP), pervious concrete (PC), and porous asphalt (PA) were able to significantly remove sediment and sediment-bound pollutant loads from runoff originating from an asphalt parking lot five times larger than the receiving permeable pavement area. Reductions in total suspended solids were similar for all three surfaces at approximately 60 percent. Clogging occurred after approximately one year, primarily due to winter sand application that led to high sediment load in spring runoff. Winter road salt application resulted in high chloride load that was initially attenuated in all three permeable pavements but later released during subsequent spring runoff events. Total phosphorus load was reduced by nearly 20 percent for PICP and PA, and 43 percent for PC. These values were likely tempered by the export of dissolved phosphorus observed in PICP and PA, but not PC. Average removal efficiencies for metals were 40, 42, and 49 percent in PA, PICP, and PC, respectively. A median pH of 10.2 in PC effluent could explain elevated removal efficiency of phosphorus and select metals in PC over PICP and PA (median = 7.5 and 7.8, respectfully) through enhanced precipitation. Elevated pH values in PC may also have led to higher removal efficiencies for select metals than PICP or PA. The environmental benefits as well as potential unintended consequences of stormwater practices like permeable pavement that utilize infiltration as a form of treatment warrant consideration in management of urban runoff.

Wisconsin

Evaluation of stormwater treatment vault with Coanda-effect screen for removal of solids and phosphorus in urban runoff

Catch basins commonly are used by cities as part of a stormwater management plan to remove sediment and associated contaminants from stormwater, keeping them in compliance with regulations. Recently, the city of Madison, Wisconsin modified traditional catch basins by incorporating a fine-mesh (1-mm) Coanda-effect screen into the design with the goal of increasing removal of sediment and organic matter from stormwater. The US Geological Survey (USGS), in cooperation with the City of Madison, installed a water-quality monitoring station at such a catch basin to quantify reductions in total suspended solids (TSS), volatile suspended solids (VSS), suspended sediment concentration (SSC), total phosphorus (TP), and dissolved phosphorus (DP) from urban stormwater before entering Lake Monona. A comparison of the cumulative load from 33 samples collected during the summers of 2016 and 2017 showed 23% and 45% reductions in TSS and SSC, respectively. A smaller reduction was observed for TP, 16%, whereas DP remained unchanged. Reported traditional catch basin sediment removal varies greatly, although typical removal rates are similar. Results from this study will help regulated municipalities determine whether the use of screened catch basins can help meet water-quality goals.

Wisconsin

Hydraulic, water-quality, and temperature performance of three types of permeable pavement under high sediment loading conditions

Three permeable pavement surfaces - asphalt (PA), concrete (PC), and interlocking pavers (PIP) - were evaluated side-by-side to measure changes to the infiltrative capacity and water quality of stormwater runoff originating from a conventional asphalt parking lot in Madison, Wisconsin. During the 24-month monitoring period (2014-16), all three permeable pavements resulted in statistically significant reductions in the cumulative load of solids (total suspended solids and suspended sediment), total phosphorus, Escherichia coli ( E. coli ), and Enterococci . Most of the removal occurred through capture and retention in the void spaces of each permeable surface and aggregate base. The largest reduction in total suspended solids was for PC at 80 percent, followed by PIP and PA at 69 and 65 percent, respectively. Reductions (generally less than 50 percent) in total phosphorus also were observed, which might have been tempered by increases in the dissolved fraction observed in PIP and PA. Conversely, PC results indicated a slight reduction in dissolved phosphorus but failed to meet statistical significance. E. coli and Enterococci were reduced by about 80 percent for PC, almost twice the amount observed for PIP and PA. Results for the PIP and PC surfaces initially indicated higher pollutant load reduction than results for the PA surface. The efficiency of PIP and PC surfaces capturing sediment, however, led to a decline in infiltration rates that resulted in more runoff flowing over, not through, the permeable surface. This result led to a decline in treatment until the permeable surface was partially restored through maintenance practices, to which PIP responded more dramatically than PC or PA. Conversely, the PA surface was capable of infiltrating most of the influent runoff volume during the monitoring period and, thus, continued to provide some level of treatment. The combined effect of underdrain and overflow drainage resulted in similar pollutant treatment for all three permeable surfaces. Temperatures below each permeable surface generally followed changes in air temperature with a more gradual response observed in deeper layers. Therefore, permeable pavement may do little to mitigate heated runoff during summer. During winter, deeper layers remained above freezing even when air temperature was below freezing. Although temperatures were not high enough to melt snow or ice accumulated on the surface, temperatures below each permeable pavement did allow void spaces to remain open, which promoted infiltration of melted ice and snow as air temperatures rose above freezing. These open void spaces could potentially reduce the need for application of deicing agents in winter because melted snow and ice would infiltrate, thereby preventing refreezing of pooled water in what is known as the “black ice” effect.

Wisconsin