Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

Open-File Report

Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

Open-File Report

Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

Water-Resources Investigations Report

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of nonpurgeable suspended organic carbon by wet-chemical oxidation and infrared spectrometry

Precision and accuracy results are described for the determination of nonpurgeable suspended organic carbon (SOC) by silver-filter filtration, wet-chemical oxidation, and infrared determination of hte resulting carbon dioxide (CO2) used at the U.S. Geological Survey's nationalWater Quality Laboratory. An aliquot of raw water isfiltered through a 0.45-micrometer silver filter. The trapped organic material is oxidized using phosphoric acid and potassium persulfate in a scaled glass ampule,and the rseulting CO2 is measured by an infrared CO2 detector. The amount of CO3 is proportional to the concentration of chemically oxidizable nonpurgeable organic carbon in the sample. The SOC method detection limit for routine analysis is 0.2 milligram per liter. The average percent recovery is 97.1 percent and the average standard deviation is 11 percent.

Open-File Report

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Determination of methylene blue active substances by spectrophotometry

A method for the determination of methylene blue active substances in whole-water samples by liquid-liquid extraction and spectrophotometric detection is described. Sulfate and sulfonate-based surfectants are reacted with methylene blue to form a blue-colored complex. The complex is extracted into chloroform, back-washed with an acidified phosphate-based buffer solution, and measured against external standards with a probe spectrophotometer. The method detection limt for routine analysis is 0.02 milligram per liter. The precision is plus/minus 10 percent relative standard deviation. The positive bias from nitrate and chloride and U.S. Geological Survey method O-3111-83 for methylene blue active substances is minized by adding a back-washing step.

Open-File Report