Ground-water recharge areas and traveltimes to pumped wells, ponds, streams, and coastal water bodies, Cape Cod, Massachusetts
Explore the source record for details and available documents.
Geology topics
Publications and source records attributed to John P. Masterson.
Explore the source record for details and available documents.
The U.S. Geological Survey, in cooperation with the National Park Service, Massachusetts Executive Office of Environmental Affairs, Cape Cod Commission, and the Towns of Eastham, Provincetown, Truro, and Wellfleet, began an investigation in 2000 to improve the understanding of the hydrogeology of the four freshwater lenses of the Lower Cape Cod aquifer system and to assess the effects of changing ground-water pumping, recharge conditions, and sea level on ground-water flow in Lower Cape Cod, Massachusetts. A numerical flow model was developed with the computer code SEAWAT to assist in the analysis of freshwater and saltwater flow. Model simulations were used to determine water budgets, flow directions, and the position and movement of the freshwater/saltwater interface. Model-calculated water budgets indicate that approximately 68 million gallons per day of freshwater recharge the Lower Cape Cod aquifer system with about 68 percent of this water moving through the aquifer and discharging directly to the coast, 31 percent flowing through the aquifer, discharging to streams, and then reaching the coast as surface-water discharge, and the remaining 1 percent discharging to public-supply wells. The distribution of streamflow varies greatly among flow lenses and streams; in addition, the subsurface geology greatly affects the position and movement of the underlying freshwater/saltwater interface. The depth to the freshwater/saltwater interface varies throughout the study area and is directly proportional to the height of the water table above sea level. Simulated increases in sea level appear to increase water levels and streamflows throughout the Lower Cape Cod aquifer system, and yet decrease the depth to the freshwater/saltwater interface. The resulting change in water levels and in the depth to the freshwater/saltwater interface from sea-level rise varies throughout the aquifer system and is controlled largely by non-tidal freshwater streams. Pumping from large-capacity municipal-supply wells increases the potential for effects on surface-water bodies, which are affected by pumping and wastewater-disposal locations and rates. Pumping wells that are upgradient of surface-water bodies potentially capture water that would otherwise discharge to these surface-water bodies, thereby reducing streamflow and pond levels. Kettle-hole ponds, such as Duck Pond in Wellfleet, that are near the top of a freshwater flow lens, appear to be more susceptible to changing pumping and recharge conditions than kettle-hole ponds closer to the coast or near discharge boundaries, such as the Herring River.
The U.S. Geological Survey has developed several ground-water models in support of an investigation of ground-water contamination being conducted by the Army National Guard Bureau at Camp Edwards, Massachusetts Military Reservation on western Cape Cod, Massachusetts. Regional and subregional steady-state models and regional transient models were used to (1) improve understanding of the hydrologic system, (2) simulate advective transport of contaminants, (3) delineate recharge areas to municipal wells, and (4) evaluate how model discretization and time-varying recharge affect simulation results. A water-table mound dominates ground-water-flow patterns. Near the top of the mound, which is within Camp Edwards, hydraulic gradients are nearly vertically downward and horizontal gradients are small. In downgradient areas that are further from the top of the water-table mound, the ratio of horizontal to vertical gradients is larger and horizontal flow predominates. The steady-state regional model adequately simulates advective transport in some areas of the aquifer; however, simulation of ground-water flow in areas with local hydrologic boundaries, such as ponds, requires more finely discretized subregional models. Subregional models also are needed to delineate recharge areas to municipal wells that are inadequately represented in the regional model or are near other pumped wells. Long-term changes in recharge rates affect hydraulic heads in the aquifer and shift the position of the top of the water-table mound. Hydraulic-gradient directions do not change over time in downgradient areas, whereas they do change substantially with temporal changes in recharge near the top of the water-table mound. The assumption of steady-state hydraulic conditions is valid in downgradient area, where advective transport paths change little over time. In areas closer to the top of the water-table mound, advective transport paths change as a function of time, transient and steady-state paths do not coincide, and the assumption of steady-state conditions is not valid. The simulation results indicate that several modeling tools are needed to adequately simulate ground-water flow at the site and that the utility of a model varies according to hydrologic conditions in the specific areas of interest.
The U.S. Geological Survey, in cooperation with the Air Force Center for Environmental Excellence, developed a three-dimensional ground-water-flow model to simulate sources of water to public-supply wells, ponds, streams, and coastal areas for average and changing pumping and recharge conditions on western Cape Cod, Massachusetts. Understanding the changing sources of water that flows to these discharge areas under changing hydrologic conditions and stresses is needed to help water-resource managers protect the quality of the drinking water and the water resources of western Cape Cod. The interconnection of hydrologic features through the ground-water-flow system on Cape Cod complicates the determination of the sources of water for changing pumping and recharge conditions. When pumping and recharge conditions change, the numerical model can help evaluate changes in the recharge areas to pumped wells, ponds, streams, and coastal areas. The steady-state recharge area and time-of-travel zones to a pumping well represent the source of water and time of travel from the water table to the well once all of the water discharging to the well entered the aquifer after pumping began. Initially, the water that discharges to a pumped well over a specified period consists of a blend of waters that entered the aquifer over time. When pumping begins, a deep well may capture water that entered the aquifer many years earlier at a great distance from the well; therefore, determining the source of water discharging to a well for specified pumping times may be more important for protecting public-water supplies than determining only the steady-state recharge area and time-of-travel zones to the well.
A numerical model was used to simulate pond-aquifer interactions under natural and stressed conditions near Snake Pond, Cape Cod, Massachusetts. Simulation results show that pond-bottom hydraulic conductivity, which represents the degree of hydraulic connection between the pond and the aquifer, is an important control on these interactions. As this parameter was incrementally increased from 10 to 350 feet per day, the rate of ground-water inflow into the pond under natural conditions increased by about 250 percent, the associated residence times of water in the pond decreased by about 50 percent, and ground-water inflow to the pond shifted closer to the pond shore. Most ground-water inflow (90 to 98 percent) was in the upper model layer, which corresponded to shallow, near-shore areas of the pond, over the entire range of pond-bottom hydraulic conductivity. Ground-water flow paths into the pond became more vertical, the contributing area to the pond became larger, and the pond captured water from greater depths in the aquifer as the hydraulic conductivity of the pond bottom was increased. The pond level, however, remained nearly constant, and regional ground-water levels and gradients differed little over the range of pond-bottom hydraulic conductivity, indicating that calibrated models with similar head solutions can have different pond-aquifer interaction characteristics. Hydrologic stresses caused by a simulated plume-containment system that specifies the extraction and injection of large volumes of ground water near the pond increased the pond level by about 0.4 foot and ground-water inflow rates into the pond by about 25 percent. Several factors related to the operation of the simulated containment system are affected by the hydraulic conductivity of the pond bottom. With increasing pond-bottom hydraulic conductivity, the amount of injected water that flows into Snake Pond increased and the amount of water recirculated between extraction and injection wells decreased. Comparison of simulations in which pond-bottom hydraulic conductivity was varied throughout the pond and simulations in which hydraulic conductivity was varied only in areas corresponding to shallow, near-shore areas of the pond indicate that the simulated hydraulic conductivity of the pond bottom in deeper parts of the pond had little effect on pond-aquifer interactions under both natural and stressed conditions.
The unconfined sand-and-gravel aquifer in western Cape Cod, Massachusetts, which is the sole source of water supply for the communities in the area, is recharged primarily from precipitation. The rate of recharge from precipitation is estimated to be about 26 inches per year (in/yr), or about 60 percent of the precipitation rate. This recharge rate yields a flow through the aquifer of about 180 million gallons per day (Mgal/d). Groundwater flows radially outward from the top of the water-table mound in the north-central part of the flow system toward the coast, as indicated by the water-table contours on the large map on this sheet. Recharge that reaches the water table near the top of the mound travels deeper through the aquifer than recharge that reaches the water table closer to the coast. All recharge to the aquifer ultimately discharges to pumping wells, streams, or coastal areas; however, some of this recharge may flow first through kettle ponds before eventually reaching these discharge points. Continued land development and population growth on western Cape Cod, and activities related to the operation of the Massachusetts Military Reservation (MMR), have created concerns regarding the supply of potable water in western Cape Cod and the quality and quantity of water discharging to ponds, streams, and coastal areas. Recent investigations estimated the future demand for drinking water in western Cape Cod, as well as the areas that contribute water to existing and proposed public-supply wells. Determining the source of freshwater that discharges to ponds, streams, and coastal areas is of critical importance in the protection of these natural resources for the communities of western Cape Cod. The purpose of this report is to illustrate concepts of ground-water recharge areas under average pumping and recharge conditions. This report presents results of an investigation conducted by the U.S. Geological Survey (USGS), in cooperation with the Air Force Center for Environmental Excellence (AFCEE), to delineate the areas that contribute recharge to public-supply wells, ponds, streams, and coastal areas on western Cape Cod for average annual pumping and recharge rates for the period of 1994–1996. The time period of 1994–1996 was selected for this analysis because it represents the average stress conditions prior to large-scale pumping, treatment, and reinjection of water from the MMR Installation Restoration Program's ground-water remediation systems. The pumping and reinjection of large amounts of water from these remediation systems would complicate greatly the delineation of ground-water recharge areas and therefore is beyond the scope of this analysis. The Chemical Spill-4 plume-containment system, however, is included in the simulation since it has been operating since 1993 and has been pumping, treating, and reinjecting only about 0.2 Mgal/d of water. Since 1996, however, AFCEE has constructed remediation systems for seven additional contaminant plumes that are not included in this analysis. Currently (1999), these systems are pumping, treating, and reinjecting about 9.7 Mgal/d. By 2002, when all of these systems, including those being designed, are expected to be operating, it is estimated that they will be pumping, treating, and reinjecting as much as 15.6 Mgal/d of water in the western Cape Cod aquifer. For additional information on the hydrology and geology of western Cape Cod, the reader is referred to the following reports: LeBlanc and others (1986), Barlow and Hess (1993), Masterson and others (1997a), Masterson and others (1997b), Masterson and others (1998), Ogden Environmental and Energy Services, Inc. (1998) and Jacobs Engineering Group, Inc. (1999).
No abstract available.
The aquifer of western Cape Cod consists of several hydrogeologic units composed of sand, gravel, silt, and clay (fig. 1) that were deposited during the late Wisconsinan glaciation of New England. The aquifer is a shallow, unconfined hydrologic system in which ground-water flows radially outward from the apex of the ground-water mound near the center of the peninsula toward the coast (fig.2). The aquifer is the sole source of water supply for the towns of Bourne, Sandwich, Falmouth, and Mashpee, and the Massachusetts Military Reservation (MMR). Previous geologic studies summarized the characteristics and relative ages of the glacial moraines and meltwater deposits and the relation of these sediments to the extent of the ice-sheet lobes during the last glaciation of southern New England (Oldale and Barlow, 1986; Hartshorn and others, 1991). Hydrogeologic studies in western Cape Cod characterized the shallow regional ground-water-flow system (LeBlanc and others, 1986) and analyzed simulated responses of the aquifer to changes in hydrologic stresses (Guswa and LeBlanc, 1985; Barlow and Hess, 1993; Masterson and Barlow, 1994; and Masterson and others, 1996). Recent concerns about widespread ground-water contamination, especially from sources on the MMR, have resulted in extensive investigations to characterize the local hydrogeology of the aquifer near the MMR (ABB Environmental Services, 1992). Masterson and others (1996) illustrated the strong influence of geology on ground-water flow and the importance of characterizing the hydrogeology to predict the migration of the contaminant plumes beneath the MMR. This report, a product of a cooperative study between the National Guard Bureau and the U.S. Geological Survey (USGS), characterizes the regional hydrogeology of the western Cape Cod aquifer on the basis of surficial glacial geology previously described by Mather and others (1940) and Oldale and Barlow (1986), and presents a new analysis of the subsurface hydrogeology. The characterization of the regional hydrogeologic framework includes a detailed analysis of the glacial sediments, including deltaic and lacustrine deposits and their sedimentary facies; a structure-contour analysis of the transition between the shallow sand and gravel deposits and the underlying fine sand, silt, and clay deposits; and a summary of the relation between lithologic characteristics (grain size and stratigraphy) and empirically determined hydraulic-conductivity values.
Three-dimensional transient ground-water-flow models that simulate both freshwater and saltwater flow were developed for the flow cells of the Cape Cod Basin to determine the effects of long-term pumping and recharge, seasonal fluctuations in pumping and recharge, and prolonged reductions of natural recharge, on the position of the freshwater-saltwater interface, water-table and pond altitudes, and streamflow and discharge to coastal marshes and embayments. Two-dimensional, finite-difference change models were developed for Martha's Vineyard and Nantucket Island basins to determine anticipated drawdowns in response to projected summer season pumping rates for 180 days of no recharge.
A steady-state, three-dimensional flow model coupled with a particle-tracking algorithm was developed to assess the complex interaction of hydrogeologic conditions affecting ground-water flow and contaminant transport--including aquifer heterogeneities, hydrologic boundaries such as ponds and streams, ground-water withdrawals, and aquifer recharge to characterize the migration of contaminants emanating from beneath the Massachusetts Military Reservation, Cape Cod, Massachusetts. The known extent of contaminant plumes were used to assess the effects of changes in model input parameters on model-calculated water-table and pond altitudes, streamflow, and water-particle pathlines. Although changes in selected simulated hydrogeologic conditions resulted in minor changes in model-calculated water-table altitudes, pond altitudes, and streamflow, these changes had significant effects on the projection of model-calculated water-particle pathlines.
An investigation of the geohydrology and of the potential for water-supply development on several of the Boston Harbor Islands, eastern Massachusetts, was conducted to evaluate the possibility of developing a permanent small-capacity water supply to support recreational activities, such as camping, hiking, and swimming. The Boston Harbor Islands, including Bumkin, Gallops, Georges, Grape, Lovell, and Peddocks Islands are part of a larger group of glacially deposited drumlins, which are composed of thick, dense, homogeneous till in their core that are overlain by a thin layer of stratified-beach deposits. The surficial materials over-lie a weathered zone of the metasedimentary Cambridge Argillite in the Boston Harbor area and were deposited by continental ice sheets that covered New England twice during the late Pleistocene Epoch, and by near-shore processes in the Holocene Epoch. The thickness of these materials range from less than 1 to about 300 feet where present. The till was deposited by glacial ice and is characterized as an unsorted matrix of sand, silt, and clay with variable amounts of stones and large boulders. The stratified deposits primarily consist of sorted and layered sand and gravel that accumulated and formed the beaches and tombolos of the harbor islands. These deposits overlie the till at altitudes generally less than 10 feet above sea level. A cross-sectional, ground-water-flow model was developed to estimate depth to the water table for a hypothetical drumlin-island flow system, which was assumed to be representative of the drumlin islands in Boston Harbor. Areas were identified in each island flow system with the greatest potential for small-capacity water-supply development based on the model-calculated depth to water and surficial geology of the islands. Model-calculated depth to water estimates were used because of the lack of available hydrologic data for the islands. Model results indicate that the simulated depth to water is less than 20 feet within 240 feet from the shore of the hypothetical drumlin-island flow system. This area on the topographic maps of the six Boston Harbor Islands roughly coincides with the high transmissivity zones of stratified-beach deposits and weathered till on the lower slopes of the drumlins where ground-water discharge and surface and subsurface runoff occurs.
A steady-state, three-dimensional numerical model coupled with a particle-tracking algorithm was developed to simulate the complex hydrogeologic conditions affecting ground-water flow and contaminant migration in the Cape Cod aquifer beneath the Massachusetts Military Reservation, Massachusetts. The known extents of the contaminant plumes beneath the reservation were incorporated into a particle-tracking analysis to improve model calibration. Particle tracking was used to evaluate the effects of simulated changes in hydraulic properties and in simulated hydrologic boundaries such as ponds and streams. The model simulations made during the calibration process indicated that changes in simulated hydraulic properties and hydrologic boundaries resulted in small changes in the water-table and pond altitudes and in streamflows, yet had a substantial effect on model-calculated groundwater flowpaths. Therefore, the characterization of contaminant migration using a model calibrated only on the basis of ground-water heads and flux may be inaccurate. The results of model simulations for the analysis of the effects of pumping and recharge on ground-water flow and contaminant migration indicated that ground-water flowpaths were greatly affected by subtle shifts in hydraulic gradients. These changes in the ground-water-flow system in response to hydrologic stresses such as pumping and recharge can be determined by the use of a particle-tracking analysis.
A study of the hydrogeology and an analysis of the ground-water-flow system near Sagamore Marsh, southeastern Massachusetts, was undertaken to improve the understanding of the current (1994 95) hydrogeologic conditions near the marsh and how the ground-water system might respond to proposed changes in the tidal-stage regime of streams that flood and drain the marsh. Sagamore Marsh is in a coastal area that is bounded to the east by Cape Cod Bay and to the south by the Cape Cod Canal. The regional geology is characterized by deltaic and glaciolacustrine sediments. The sediments consist of gravel, sand, silt, and clay and are part of the Plymouth-Carver regional aquifer system. The glacial sediments are hounded laterally by marine sand, silt, and clay along the coast. The principal aquifer in the area consists of fine to coarse glacial sand and is locally confined by fine-grained glaciolacustrine deposits consisting of silt and sandy clay and fine-grained salt-marsh sediments consisting of peat and clay. The aquifer is underlain by finer grained glaciolacustrine sediments in upland areas and by marine clay along the coast. Shallow ground water discharges primarily along the edge of the marsh, whereas deeper ground water flows beneath the marsh and discharges to Cape Cod Bay. Tidal pulses originating from Cape Cod Bay and from tidal channels in the marsh are rapidly attenuated in the subsurface. Tidal ranges in Cape Cod Bay and in the tidal channels were on the order of 9 and 1.5 feet, respectively, whereas tidal ranges in the ground-water levels were less than 0.2 foot. Tidal pulses measured in the water table beneath a barrier beach between the marsh and Cape Cod Bay were more in phase with tidal pulses from Cape Cod Bay than with tidal pulses from the tidal channels in Sagamore Marsh, whereas tidal pulses in the regional aquifer were more in phase with tidal pulses from the tidal channels. A 5-day aquifer test at a public-supply well adjacent to the marsh gave a transmissivity of the regional aquifer of 9,300 to 10,900 feet squared per day and a hydraulic conductivity of 181 to 213 feet per day, assuming a saturated thickness of the aquifer of 51.3 feet. The regional aquifer became unconfined near the pumped well during the test. The ratio of tidal ranges in the tidal channel to the ranges in the underlying aquifer at two sites (the lower and upper marsh) indicated aquifer diffusivities for the marsh sediments of 380 and 170 feet squared per day; these values correspond to hydraulic conductivities of 2.5 x 10 -3 and 1.7 x 10 -3 feet per day, respectively. The maximum distances from the tidal channel at the lower and upper marsh sites where tidal ranges would exceed 0.01 foot, as calculated from aquifer diffusivities and current (1995) tidal ranges in the tidal channels, were 24.4 and 26.7 feet, respectively. The maximum distances from the tidal channel where tidal pulses in the ground water would exceed 0.01 foot, using potential increased tidal stages resulting from proposed tidal-stage modifications and predicted by the U.S. Army Corps of Engineers, were 37.1 and 42.0 feet, respectively. A numerical model of the marsh and surrounding aquifer system indicated that the contributing area for the supply well adjacent to the marsh, for current (1994) pumping conditions, extends toward Great Herring Pond, about 2 miles northwest (upgradient) of the well, and does not extend beneath the marsh. The model also indicates that the predicted increases in tidal stages in the marsh will have a negligible effect on local ground-water levels.
The effects of changing patterns of ground-water pumping and aquifer recharge on the surface-water and ground-water hydrologic systems were determined for the Cape Cod, Martha's Vineyard, and Nantucket Island Basins. Three-dimensional, transient, ground-water-flow modelS that simulate both freshwater and saltwater flow were developed for the f1ow cells of Cape Cod which currently have large-capacity public-supply wells. Only the freshwater-flow system was simulated for the Cape Cod flow cells where public-water supply demands are satisfied by small-capacity domestic wells. Two- dimensional, finite-difference, change models were developed for Martha's Vineyard and Nantucket Island to determine the projected drawdowns in response to projected in-season pumping rates for 180 days of no aquifer recharge. Results of the simulations indicate very little change in the position of the freshwater-saltwater interface from predevelopment flow conditions to projected ground-water pumping and recharge rates for Cape Cod in the year 2020. Results of change model simulations for Martha's Vineyard and Nantucket Island indicate that the greatest impact in response to projected in-season ground-water pumping occurs at the pumping centers and the magnitude of the drawdowns are minimal with respect to the total thickness of the aquifers.