Geology ReportsSearch

Geology topics

Joel G. Burken

Publications and source records attributed to Joel G. Burken.

7 recordsLinked to original sources

Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman’s correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

Nebraska

Contaminant gradients in trees: Directional tree coring reveals boundaries of soil and soil-gas contamination with potential applications in vapor intrusion assessment

Contaminated sites pose ecological and human-health risks through exposure to contaminated soil and groundwater. Whereas we can readily locate, monitor, and track contaminants in groundwater, it is harder to perform these tasks in the vadose zone. In this study, tree-core samples were collected at a Superfund site to determine if the sample-collection location around a particular tree could reveal the subsurface location, or direction, of soil and soil-gas contaminant plumes. Contaminant-centroid vectors were calculated from tree-core data to reveal contaminant distributions in directional tree samples at a higher resolution, and vectors were correlated with soil-gas characterization collected using conventional methods. Results clearly demonstrated that directional tree coring around tree trunks can indicate gradients in soil and soil-gas contaminant plumes, and the strength of the correlations were directly proportionate to the magnitude of tree-core concentration gradients (spearman’s coefficient of -0.61 and -0.55 in soil and tree-core gradients, respectively). Linear regression indicates agreement between the concentration-centroid vectors is significantly affected by in-planta and soil concentration gradients and when concentration centroids in soil are closer to trees. Given the existing link between soil-gas and vapor intrusion, this study also indicates that directional tree coring might be applicable in vapor intrusion assessment.

Missouri

Tree sampling as a method to assess vapor intrusion potential at a site characterized by VOC-contaminated groundwater and soil

Vapor intrusion (VI) by volatile organic compounds (VOCs) in the built environment presents a threat to human health. Traditional VI assessments are often time-, cost-, and labor-intensive; whereas traditional subsurface methods sample a relatively small volume in the subsurface and are difficult to collect within and near structures. Trees could provide a similar subsurface sample where roots act as the “sampler’ and are already onsite. Regression models were developed to assess the relation between PCE concentrations in over 500 tree-core samples with PCE concentrations in over 50 groundwater and 1000 soil samples collected from a tetrachloroethylene- (PCE-) contaminated Superfund site and analyzed using gas chromatography. Results indicate that in planta concentrations are significantly and positively related to PCE concentrations in groundwater samples collected at depths less than 20 m (adjusted R 2 values greater than 0.80) and in soil samples (adjusted R 2 values greater than 0.90). Results indicate that a 30 cm diameter tree characterizes soil concentrations at depths less than 6 m over an area of 700–1600 m 2 , the volume of a typical basement. These findings indicate that tree sampling may be an appropriate method to detect contamination at shallow depths at sites with VI.

Missouri

Persistence and microbial source tracking of Escherichia coli at a swimming beach at Lake of the Ozarks State Park, Missouri

The Missouri Department of Natural Resources (MDNR) has closed or posted advisories at public beaches at Lake of the Ozarks State Park in Missouri because of Escherichia coli ( E. coli ) concentration exceedances in recent years. Spatial and temporal patterns of E. coli concentrations, microbial source tracking, novel sampling techniques, and beach-use patterns were studied during the 2012 recreational season to identify possible sources, origins, and occurrence of E. coli contamination at Grand Glaize Beach (GGB). Results indicate an important source of E. coli contamination at GGB was E. coli released into the water column by bathers resuspending avian-contaminated sediments, especially during high-use days early in the recreational season. Escherichia coli concentrations in water, sediment, and resuspended sediment samples all decreased throughout the recreational season likely because of decreasing lake levels resulting in sampling locations receding away from the initial spring shoreline as well as natural decay and physical transport out of the cove. Weekly MDNR beach monitoring, based solely on E. coli concentrations, at GGB during this study inaccurately predicted E. coli exceedances, especially on weekends and holidays. Interestingly, E. coli of human origin were measured at concentrations indicative of raw sewage in runoff from an excavation of a nearby abandoned septic tank that had not been used for nearly two years.

Missouri

Occurrence and origin of Escherichia coli in water and sediments at two public swimming beaches at Lake of the Ozarks State Park, Camden County, Missouri, 2011-13

In the past several years, the Missouri Department of Natural Resources has closed two popular public beaches, Grand Glaize Beach and Public Beach 1, at Lake of the Ozarks State Park in Osage Beach, Missouri when monitoring results exceeded the established Escherichia coli (E. coli) standard. As a result of the beach closures, the U.S. Geological Survey and Missouri University of Science and Technology, in cooperation with the Missouri Department of Natural Resources, led an investigation into the occurrence and origins of E. coli at Grand Glaize Beach and Public Beach 1. The study included the collection of more than 1,300 water, sediment, and fecal source samples between August 2011 and February 2013 from the two beaches and vicinity. Spatial and temporal patterns of E. coli concentrations in water and sediments combined with measurements of environmental variables, beach-use patterns, and Missouri Department of Natural Resources water-tracing results were used to identify possible sources of E. coli contamination at the two beaches and to corroborate microbial source tracking (MST) sampling efforts. Results from a 2011 reconnaissance sampling indicate that water samples from Grand Glaize Beach cove contained significantly larger E. coli concentrations than adjacent coves and were largest at sites at the upper end of Grand Glaize Beach cove, indicating a probable local source of E. coli contamination within the upper end of the cove. Results from an intensive sampling effort during 2012 indicated that E. coli concentrations in water samples at Grand Glaize Beach cove were significantly larger in ankle-deep water than waist-deep water, trended downward during the recreational season, significantly increased with an increase in the total number of bathers at the beach, and were largest during the middle of the day. Concentrations of E. coli in nearshore sediment (sediment near the shoreline) at Grand Glaize Beach were significantly larger in foreshore samples (samples collected above the shoreline) than in samples collected in ankle-deep water below the shoreline, significantly larger in the left and middle areas of the beach than the right area, and substantially larger than similar studies at E. coli- contaminated beaches on Lake Erie in Ohio. Concentrations of E. coli in the water column also were significantly larger after resuspension of sediments. Results of MST indicate a predominance of waterfowl-associated markers in nearshore sediments at Grand Glaize Beach consistent with frequent observations of goose and vulture fecal matter in sediment, especially on the left and middle areas of the beach. The combination of spatial and temporal sampling and MST indicate that an important source of E. coli contamination at Grand Glaize Beach during 2012 was E. coli released into the water column by bathers resuspending E. coli-contaminated sediments, especially during high-use days early in the recreational season.

Missouri

Dendrochemistry of multiple releases of chlorinated solvents at a former industrial site

Trees can take up and assimilate contaminants from the soil, subsurface, and groundwater. Contaminants in the transpiration stream can become bound or incorporated into the annual rings formed in trees of the temperate zones. The chemical analysis of precisely dated tree rings, called dendrochemistry, can be used to interpret past plant interactions with contaminants. This investigation demonstrates that dendrochemistry can be used to generate historical scenarios of past contamination of groundwater by chlorinated solvents at a site in Verl, Germany. Increment cores from trees at the Verl site were collected and analyzed by energy-dispersive X-ray fluorescence (EDXRF) line scanning. The EDXRF profiles showed four to six time periods where tree rings had anomalously high concentrations of chlorine (Cl) as an indicator of potential contamination by chlorinated solvents.

Verl

Assessment of subsurface chlorinated solvent contamination using tree cores at the front street site and a former dry cleaning facility at the Riverfront Superfund site, New Haven, Missouri, 1999-2003

Tree-core sampling has been a reliable and inexpensive tool to quickly assess the presence of shallow (less than about 30 feet deep) tetrachloroethene (PCE) and trichloroethene (TCE) contamination in soils and ground water at the Riverfront Superfund Site. This report presents the results of tree-core sampling that was successfully used to determine the presence and extent of chlorinated solvent contamination at two sites, the Front Street site (operable unit OU1) and the former dry cleaning facility, that are part of the overall Riverfront Superfund Site. Traditional soil and ground-water sampling at these two sites later confirmed the results from the tree-core sampling. Results obtained from the tree-core sampling were used to design and focus subsequent soil and ground-water investigations, resulting in substantial savings in time and site assessment costs. The Front Street site is a small (less than 1-acre) site located on the Missouri River alluvium in downtown New Haven, Missouri, about 500 feet from the south bank of the Missouri River. Tree-core sampling detected the presence of subsurface PCE contamination at the Front Street site and beneath residential property downgradient from the site. Core samples from trees at the site contained PCE concentrations as large as 3,850 mg-h/kg (micrograms in headspace per kilogram of wet core) and TCE concentrations as large as 249 mg-h/kg. Soils at the Front Street site contained PCE concentrations as large as 6,200,000 mg/kg (micrograms per kilogram) and ground-water samples contained PCE concentrations as large as 11,000 mg/L (micrograms per liter). The former dry cleaning facility is located at the base of the upland that forms the south bank of the Missouri River alluvial valley. Tree-core sampling did not indicate the presence of PCE or TCE contamination at the former dry cleaning facility, a finding that was later confirmed by the analyses of soil samples collected from the site. The lateral extent of PCE contamination in trees was in close agreement with the extent of subsurface PCE contamination determined using traditional soil and ground-water sampling methods. Trees growing in soils containing PCE concentrations of 60 to 5,700 mg/kg or larger or overlying ground water containing PCE concentrations from 5 to 11,000 mg/L generally contained detectable concentrations of PCE. The depth to contaminated ground water was about 20 to 25 feet below the land surface. Significant quantitative relations [probability (p) values of less than 0.05 and correlation coefficient (r2) values of 0.88 to 0.90] were found between PCE concentrations in trees and subsurface soils between 4 and 16 feet deep. The relation between PCE concentrations in trees and underlying ground water was less apparent (r2 value of 0.17) and the poor relation is thought to be the result of equilibrium with PCE concentrations in soil and vapor in the unsaturated zone. Based on PCE concentrations detected in trees at the Front Street site and trees growing along contaminated tributaries in other operable units, and from field hydroponic experiments using hybrid poplar cuttings, analysis of tree-core samples appears to be able to detect subsurface PCE contamination in soils at levels of several hundred micrograms per liter or less and PCE concentrations in the range of 8 to 30 mg/L in ground water in direct contact with the roots. Loss of PCE from tree trunks by diffusion resulted in an exponential decrease in PCE concentrations with increasing height above the land surface in most trees. The rate of loss also appeared to be a function of the size and growth characteristics of the tree as some trees exhibited a linear loss with increasing height. Diffusional loss of PCE in small (0.5-inch diameter) trees was observed to occur at a rate more than 10 times larger than in trees 6.5 inches in diameter. Concentrations of PCE also exhibited directional variability around the tree trunks and concentration differe

Scientific Investigations Report