Geothermal district energy systems coupled with seasonal underground thermal energy storage: A U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

Arizona, Illinois, Maryland, Michigan, Mississippi

Prioritizing resource protection and understanding potential susceptibility of springs to surficial changes in a low-temperature geothermal system

Geothermal systems are vulnerable to changes in water budget and composition, requiring science-based management. This study uses a dataset of spring water temperatures, time series of groundwater residence time tracers (tritium and carbon-14), and stable isotopes of water to understand geothermal flow in a low-temperature geothermal system in north west Colorado, United States (Steamboat Springs). The geothermal system is bisected by the Yampa River, necessitating a stream mass balance approach to quantify total discharge. Time series analysis of water temperature data provides a ranked list of features more susceptible to surficial changes, which is corroborated using time series of tritium which indicate spatially distinct patterns of mixing between modern and pre-modern groundwater. All springs contain a portion of pre-modern groundwater that is thousands to tens of thousands of years old, a period coinciding with melting of extensive Pleistocene glaciers that was likely one of the recharge sources to the geothermal system. Stream mass balance indicates that greater than 80% of the total geothermal discharge is derived from diffuse or small springs, highlighting the extensive nature of the geothermal outflow zone and the association with local geologic structures. This study provides baseline data to support management of the Steamboat Springs geothermal system and indicates the utility of these approaches in developing science-based geothermal management.

Colorado

Sources of water and salts for the Zuni Salt Lake in west-central New Mexico

The Zuni Salt Lake is located in a maar in west-central New Mexico and contains hypersaline water that has long been used by Native Americans for religious purposes and the collection of salt. There have been several investigations suggesting different sources for the water and salt to the lake. Springs, seeps, and ephemeral streamflow have all been observed to contribute freshwater to the lake, and brackish to hypersaline seeps have been documented along the banks of the lake. This report summarizes the findings of a study that characterizes the lake’s hydrology, its water and salinity sources, and the hydrogeologic conceptual model. Regional groundwater levels indicate that each of the aquifers in the area have the potential to discharge groundwater to the lake. There is also evidence of vertical groundwater flow pathways at the maar that were likely created by the igneous intrusion that fractured the intersecting aquifers. A detailed water budget was constructed from continuous lake stage, precipitation, and evaporation data to estimate the groundwater inflow to the Zuni Salt Lake. It was determined that groundwater inflow to the lake is 441 ±94 acre-feet per year, which composes as much as 77 percent of the total inflows. The high sodium and chloride concentrations measured in two hypersaline samples collected near the lake indicate that the majority of the dissolved solids entering the lake are from a hypersaline groundwater source. The geochemical and isotopic compositions measured in the lake and surrounding features support the interpretation that hypersaline groundwater is the primary source of salts to the lake, which is likely sourced from the older (and deeper) Permian units. The hypersaline groundwater samples collected during this investigation have a unique aqueous chemistry relative to each of the mapped aquifers, and variability in groundwater compositions is interpreted to result from differences in minerology and residence time.

New Mexico

Reservoir thermal energy storage pre-assessment for the United States

Storing thermal energy underground for later use in electricity production or direct-use heating/cooling is a promising, viable, and economical green energy option. Reservoir thermal energy storage (RTES) is one such option, which stores energy in underutilized permeable strata with low ambient groundwater flow rates and more geochemically evolved (e.g. brackish/saline) waters relative to overlying principal aquifer systems. The U.S. Geological Survey has begun assessing RTES potential nationally by focusing on five generalized geologic regions (Basin and Range, Coastal Plain, Illinois Basin, Michigan Basin, Pacific Northwest) across the United States. Hydrogeologic reservoir models are developed for the following eight metropolitan area cities within those regions to evaluate RTES performance across different climates and subsurface conditions: Albuquerque, New Mexico; Charleston, South Carolina; Chicago and Decatur, Illinois; Lansing, Michigan; Memphis, Tennessee; Phoenix, Arizona; and Portland, Oregon. Evaluated metrics include estimated required well spacing, thermal storage capacity, and thermal recovery efficiency through time. Also considered for each reservoir are potential complicating factors, including reservoir depth, thermally driven free convection, and groundwater salinity. This work focuses on direct-use cooling because the need for cooling modern office buildings greatly exceeds that for heating in most parts of the country (Falta and others, 2016); however, the evaluated metrics are also relevant to heating and electricity applications. Results indicate that favorable RTES conditions exist in each region, with the Coastal Plain and Basin and Range being especially favorable for thermal storage capacity, while the Pacific Northwest and Michigan Basin excel at energy recovery for the evaluated cooling application. The results underscore the utility of developing maps of thermal storage capacity, subsurface temperature models, and volumetric estimates of thermal storage capacity to serve as key RTES resource classification standards. Overall, this pre-assessment provides a basic understanding of RTES potential in several cities and geologic regions throughout the country and will aid ongoing thermal energy storage assessment efforts.

Arizona, Illinois, Michigan, New Mexico, Oregon, S