Geology Reports⌕ Search

Geology topics

H.F. Prest

Publications and source records attributed to H.F. Prest.

2 recordsLinked to original sources

Overview and comparison of lipid-containing semipermeable membrane devices and oysters (Crassostrea gigas) for assessing organic chemical exposure

We performed 20-d, flow-through exposures of lipid-containing semipermeable membrane devices (SPMDs) and Pacific oysters ( Crassostrea gigas ) to three concentrations (nominally 10, 100, and 250 ng/L) of a diverse mixture of polycyclic aromatic hydrocarbons (PAHs). Exposure water was seawater free of particulates larger than 0.1 μm. The results of these controlled laboratory studies demonstrated that SPMDs and oysters concentrate the same chemicals but that the relative amounts accumulated are different. For oysters, the 20-d mean (across treatments) concentration factors (CFs) of test compounds with log K ow ≤ 4.8 were much lower (4.0- to 20-fold lower) than those of the same compounds in SPMDs. In contrast, the 20-d CFs of PAHs with log K ow ≥ 5.6 in oysters from the low-level treatment were higher than the corresponding CFs for SPMDs. The CFs of these compounds in oysters from the low-level treatment ranged from approximately 3.0- to 13-fold higher than those in oysters from the high-level treatment. This physiologically mediated difference in oyster CFs appears to be linked to active feeding in the low-level treatment and to apparent toxicity-induced cessation of feeding (i.e., valve closure) in the high-level treatment. Because CFs for these compounds in oysters were not independent of exposure concentrations, it follows that tissue levels were not proportional to exposure concentration. However, both sampling approaches have advantages and disadvantages, and the appropriateness of their use depends on the goals of a given study.

Environmental Toxicology and Chemistry↗

Determination of bioavailable contaminants in the lower Missouri River following the flood of 1993

The semipermeable membrane device (SPMD) technology was employed to determine the presence of bioavailable organochlorine pesticides (OCs), polychlorinated biphenyls (PCBs), and polyaromatic hydrocarbons (PAHs)in the water of the main stem of the lower Missouri River and three of its tributaries. The SPMDs were deployed in 1994 following the extensive flood of 1993. Specifically, the SPMDs were deployed for 28 days at Wilson State Park, IA; Nebraska City, NE; Parkville, MO; the Kansas River in Kansas City, KS; Napoleon, MO; the Grand River; Glasgow, MO; the Missouri River upstream from the confluence of the Gasconade River; the Gasconade River, and Hermann, MO. Contaminant residues were found at all sites and at higher concentrations than found in the earlier pre-flood sampling. For example, in the present study, dieldrin was found to range from a low of 110 ng/sample in the Gasconade River to a high of 2000 ng/sample at Glasgow, while in the pre- flood sampling, dieldrin ranged from a low of 64 ng/sample at Sioux City to a high of 800 ng/sample at Glasgow. In contrast to the 1992 sampling, residues of PCBs were found at all 1994 sampling sites except the Gasconade River. Samples from Wilson State Park and the Grand River had 3100 and 2700 ng of PCBs/sample, respectively. These two concentrations are about an order of magnitude higher than the older sites and are likely indicative of point source inputs. PAHs were present in SPMD samples from three sites near Kansas City. The contaminant residues sequestered by the SPMDs represent an estimation of the bioavailable (via respiration) contaminants present in the main stem of the lower Missouri River and three of its major tributaries following an extensive flood event.The semipermeable membrane device (SPMD) technology was employed to determine the presence of bioavailable organochlorine pesticides, polychlorinated biphenyls, and polyaromatic hydrocarbons in the water of the main stem of the lower Missouri River and three of its tributaries. The SPMD were deployed in 1994 following an extensive flood in 1993. Contaminants residues were found at all sites and at higher concentrations than found in the earlier pre-flood sampling.

Environmental Science & Technology↗