Geology ReportsSearch

Geology topics

G. S. Campbell

Publications and source records attributed to G. S. Campbell.

3 recordsLinked to original sources

Calibration and temperature correction of heat dissipation matric potential sensors

This paper describes how heat dissipation sensors, used to measure soil water matric potential, were analyzed to develop a normalized calibration equation and a temperature correction method. Inference of soil matric potential depends on a correlation between the variable thermal conductance of the sensor's porous ceramic and matric potential. Although this correlation varies among sensors, we demonstrate a normalizing procedure that produces a single calibration relationship. Using sensors from three sources and different calibration methods, the normalized calibration resulted in a mean absolute error of 23% over a matric potential range of −0.01 to −35 MPa. Because the thermal conductivity of variably saturated porous media is temperature dependent, a temperature correction is required for application of heat dissipation sensors in field soils. A temperature correction procedure is outlined that reduces temperature dependent errors by 10 times, which reduces the matric potential measurement errors by more than 30%. The temperature dependence is well described by a thermal conductivity model that allows for the correction of measurements at any temperature to measurements at the calibration temperature.

Soil Science Society of America Journal

PHREATOPHYTE WATER USE ESTIMATED BY EDDY-CORRELATION METHODS.

Water-use was estimated for three phreatophyte communities: a saltcedar community and an alkali-Sacaton grass community in New Mexico, and a greasewood rabbit-brush-saltgrass community in Colorado. These water-use estimates were calculated from eddy-correlation measurements using three different analyses, since the direct eddy-correlation measurements did not satisfy a surface energy balance. The analysis that seems to be most accurate indicated the saltcedar community used from 58 to 87 cm (23 to 34 in. ) of water each year. The other two communities used about two-thirds this quantity.

Conference Paper

Use of Peltier coolers as soil heat flux transducers

Peltier coolers were modified and calibrated to serve as soil heat flux transducers. The modification was to fill their interiors with epoxy. The average calibration constant on 21 units was 13.6 ± 0.8 kW m −2 V −1 at 20°C. This sensitivity is about eight times that of the two thermopile transducers with which comparisons were made. The temperature coefficients of the Peltier cooler transducers avg −0.034 kW m −2 V −1 °C −1 , whereas those of the two thermopile transducers were only 25% as large, relative to their calibration constants. The thermal conductivity of the Peltier cooler transducers was 0.4 W m −1 °C −1 , which is comparable to that of dry soil. The cost of an unmodified Peltier cooler is around 20 dollars.

Soil Science Society of America Journal