Geology ReportsSearch

Geology topics

G. Bowman

Publications and source records attributed to G. Bowman.

2 recordsLinked to original sources

Aquatic toxicity of airfield-pavement deicer materials and implications for airport runoff

Concentrations of airfield-pavement deicer materials (PDM) in a study of airport runoff often exceeded levels of concern regarding aquatic toxicity. Toxicity tests on Vibrio fischeri, Pimephales promelas, Ceriodaphnia dubia, and Pseudokirchneriella subcapitata (commonly known as Selenastrum capricornutum) were performed with potassium acetate (K-Ac) PDM, sodium formate (Na-For) PDM, and with freezing- point depressants (K-Ac and Na-For). Results indicate that toxicity in PDM is driven by the freezing-point depressants in all tests except the Vibrio fisheri test for Na-For PDM which is influenced by an additive. Acute toxicity end points for different organisms ranged from 298 to 6560 mg/L (as acetate) for K-Ac PDM and from 1780 to 4130 mg/L (as formate) for Na- For PDM. Chronic toxicity end points ranged from 19.9 to 336 mg/L (as acetate) for K-Ac PDM and from 584 to 1670 mg/L (as formate) for Na-For PDM. Sample results from outfalls at General Mitchell International Airport in Milwaukee, Wl (GMIA) indicated that 40% of samples had concentrations greater than the aquatic-life benchmark for K-Ac PDM. K-Ac has replaced urea during the 1990s as the most widely used PDM at GMIA and in the United States. Results of ammonia samples from airport outfalls during periods when urea-based PDM was used at GMIA indicated that41% of samples had concentrations exceeding the U.S. Environmental Protection Agency (USEPA) 1 -h water-quality criterion. The USEPA 1-h water-quality criterion for chloride was exceeded in 68% of samples collected in the receiving stream, a result of road-salt runoff from urban influence near the airport. Results demonstrate that PDM must be considered to comprehensively evaluate the impact of chemical deicers on aquatic toxicity in water containing airport runoff. ?? 2009 American Chemical Society.

Environmental Science & Technology

Effect of well disinfection on arsenic in ground water

Domestic water wells are routinely subjected to in situ chemical disinfection treatments to control nuisance or pathogenic bacteria. Most treatments are chlorine based and presumably cause strongly oxidizing conditions in the wellbore. Water resource managers in Wisconsin were concerned that such treatments might facilitate release of arsenic from sulfide minerals disseminated within a confined sandstone aquifer. To test this hypothesis, a well was subjected to four disinfection treatments over 9 months time. The first treatment consisted of routine pumping of the well without chemical disinfection; three subsequent treatments included chlorine disinfection and pumping. Pretreatment arsenic concentrations in well water ranged from 7.4 to 18 ??g/L. Elevated arsenic concentrations up to 57 ??g/L in the chemical treatment solutions purged from the well are attributed to the disintegration or dissolution of biofilms or scale. Following each of the four treatments, arsenic concentrations decreased to less than 10 ??g/L during a period of pumping. Arsenic concentrations generally returned to pretreatment levels under stagnant, nonpumping conditions imposed following each treatment. Populations of iron-oxidizing, heterotrophic, and sulfate-reducing bacteria decreased following chemical treatments but were never fully eradicated from the well. Strongly oxidizing conditions were induced by the chlorine-based disinfections, but the treatments did not result in sustained increases in well water arsenic. Results suggest that disruption of biofilm and mineral deposits in the well and the water distribution system in tandem with chlorine disinfection can improve water quality in this setting. ?? 2008 The Author(s).

Ground Water Monitoring and Remediation