Geology ReportsSearch

Geology topics

Fredrick E. Gebhardt

Publications and source records attributed to Fredrick E. Gebhardt.

4 recordsLinked to original sources

Enhanced bioremediation of RDX and co-contaminants perchlorate and nitrate using an anaerobic dehalogenating consortium in a fractured rock aquifer

The potential neurotoxic and carcinogenic effects of the explosives compound RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine) on human health requires groundwater remediation strategies to meet low cleanup goals. Bioremediation of RDX is feasible through biostimulation of native microbes with an organic carbon donor but may be less efficient, or not occur at all, in the presence of the common co-contaminants perchlorate and nitrate. Laboratory tests compared biostimulation with bioaugmentation to achieve anaerobic degradation of RDX, perchlorate, and nitrate; a field pilot test was then conducted in a fractured rock aquifer with the selected bioaugmentation approach. Insignificant reduction of RDX, perchlorate, or nitrate was observed by the native microbes in microcosms, with or without biostimulation by addition of lactate. Tests of the RDX-degrading ability of the microbial consortium WBC-2, originally developed for dehalogenation of chlorinated volatile organic compounds, showed first-order biodegradation rate constants ranging from 0.57 to 0.90 per day (half-lives 1.2 to 0.80 days). WBC-2 sustained degradation without daughter product accumulation when repeatedly amended with RDX and lactate for a year. In microcosms with groundwater containing perchlorate and nitrate, RDX degradation began without delay when bioaugmented with 10% WBC-2. Slower RDX degradation occurred with 3% or 5% WBC-2 amendment, indicating a direct relation with cell density. Transient RDX daughter compounds included methylene dinitramine, MNX, and DNX. With WBC-2 amendment, nitrate concentrations immediately decreased to near or below detection, and perchlorate degradation occurred with half-lives of 25 to 34 days. Single-well injection tests with WBC-2 and lactate showed that the onset of RDX degradation coincided with the onset of sulfide production, which was affected by the initial perchlorate concentration. Bioegradation rates in the pilot injection tests agreed well with those measured in the microcosms. These results support bioaugmentation with an anaerobic culture as a remedial strategy for sites contaminated with RDX, nitrate, and perchlorate.

New Mexico

Geochemical trends and natural attenuation of RDX, nitrate, and perchlorate in the hazardous test area Fractured-Granite aquifer, White Sands Missile Range, New Mexico, 1996-2006

A fractured-granite aquifer at White Sands Missile Range is contaminated with the explosive compound RDX, nitrate, and perchlorate (oxidizer associated with rocket propellant) from the previous use of the Open Burn/Open Detonation site at the Hazardous Test Area. RDX, nitrate, and perchlorate ground-water concentrations were analyzed to examine source characteristics, spatial and temporal variability, and the influence of the natural attenuation processes of dilution and degradation in the Hazardous Test Area fractured-granite aquifer. Two transects of ground-water wells from the existing monitoring-site network - one perpendicular to ground-water flow (transect A-A') and another parallel to ground-water flow (transect B-B') - were selected to examine source characteristics and the spatial and temporal variability of the contaminant concentrations. Ground-water samples collected in 2005 from a larger sampling of monitoring sites than the two transects were analyzed for various tracers including major ions, trace elements, RDX degradates, dissolved gases, water isotopes, nitrate isotopes, and sulfate isotopes to examine the natural attenuation processes of dilution and degradation. Recharge entrains contaminants at the site and transports them downgradient towards the Tularosa Basin floor through a poorly connected fracture system(s). From 1996 to 2006, RDX, nitrate, and perchlorate concentrations in ground water downgradient from the Open Burn/Open Detonation site have been relatively stable. RDX, nitrate, and perchlorate in ground water from wells near the site indicate dispersed contaminant sources in and near the Open Burn/Open Detonation pits. The sources of RDX and nitrate in the pit area have shifted with time, and the shift correlates with the regrading of the south and east berms of each pit in 2002 and 2003 following closure of the site. The largest RDX concentrations were in ground water about 0.1 mile downgradient from the pits, the largest perchlorate concentrations were in ground water about 0.15 mile downgradient from the pits, and the largest nitrate concentrations were in ground water about 0.25 mile down-gradient from the pits. Strong and moderate correlation of water level and the contaminant concentrations near the source areas and low correlation outside and downgradient from the source areas indicates a diminishing of the water level/contaminant relation with downgradient flow. Ground water was not progressively older at all locations downgradient from the Open Burn/Open Detonation site indicating multiple recharge areas. Major ion and strontium concentrations and d2H and d18O values identified similar sources of recharge waters comprising the aquifer except along the basin periphery where recharge water may be influenced by dissolution of mineral assemblages associated with ore deposits that are present along the basin margins. Ground-water ages, dissolved-solids concentrations, and calcium-strontium concentrations indicate limited or partial connectivity between fractures and contributions of uncontaminated recharge water downgradient from the site that dilutes contaminant concentrations. Changes in RDX and nitrate concentration patterns, the presence of methane, changes in carbon dioxide concentrations and d15N and d34S values, and variable reduction-oxidation conditions suggest degradation of contaminants in the downgradient direction. Estimated values of electron potential were assigned to ground water collected in October 2005 from all monitoring sites at the Hazardous Test Area. Moderate to strong reducing conditions were present upgradient from the Open Burn/Open Detonation site, at the site, and at various locations downgradient from the site, but the aquifer contained well-oxygenated water between many of the reducing areas. The spatial variability of reduction-oxidation conditions in the aquifer exemplifies the partial connectivity of the fracture system(s). Dilution of the contaminants i

New Mexico

Ground-water hydrology and water quality of the Southern High Plains Aquifer, Cannon Air Force Base, Curry County, New Mexico, 1994-2005

In cooperation with the U.S. Air Force, the U.S. Geological Survey has collected hydrologic data about the Southern High Plains aquifer at Cannon Air Force Base in east-central New Mexico since 1994. Under the guidance of the State of New Mexico, ground-water quality of the aquifer has been analyzed as part of annual monitoring at regulated sites at the base. This report provides a summary and interpretation of all available hydrologic data collected by the U.S. Geological Survey for Cannon Air Force Base environmental managers for the regulated sites of Landfill 5 and the Sewage Lagoons between 1994 and 2005.

New Mexico

Ground-water hydrology and water quality of the southern high plains aquifer, Melrose Air Force Range, Cannon Air Force Base, Curry and Roosevelt Counties, New Mexico, 2002-03

In cooperation with the U.S. Air Force, the U.S. Geological Survey characterized the ground-water hydrology and water quality at Melrose Air Force Range in east-central New Mexico. The purpose of the study was to provide baseline data to Cannon Air Force Base resource managers to make informed decisions concerning actions that may affect the ground-water system. Five periods of water-level measurements and four periods of water-quality sample collection were completed at Melrose Air Force Range during 2002 and 2003. The water-level measurements and water-quality samples were collected from a 29-well monitoring network that included wells in the Impact Area and leased lands of Melrose Air Force Range managed by Cannon Air Force Base personnel. The purpose of this report is to provide a broad overview of ground-water flow and ground-water quality in the Southern High Plains aquifer in the Ogallala Formation at Melrose Air Force Range. Results of the ground-water characterization of the Southern High Plains aquifer indicated a local flow system in the unconfined aquifer flowing northeastward from a topographic high, the Mesa (located in the southwestern part of the Range), toward a regional flow system in the unconfined aquifer that flows southeastward through the Portales Valley. Ground water was less than 55 years old across the Range; ground water was younger (less than 25 years) near the Mesa and ephemeral channels and older (25 years to 55 years) in the Portales Valley. Results of water-quality analysis indicated three areas of different water types: near the Mesa and ephemeral channels, in the Impact Area of the Range, and in the Portales Valley. Within the Southern High Plains aquifer, a sodium/chloride-dominated ground water was found in the center of the Impact Area of the Range with water-quality characteristics similar to ground water from the underlying Chinle Formation. This sodium/chloride-dominated ground water of the unconfined aquifer in the Impact Area indicates a likely connection with the deeper water-producing zone. No pesticides, explosives, volatile organic compounds, semivolatile organic compounds, organic halogens, or perchlorate were found in water samples from the Southern High Plains aquifer at the Range.

Scientific Investigations Report