Geology ReportsSearch

Geology topics

Fred W. Falls

Publications and source records attributed to Fred W. Falls.

2 recordsLinked to original sources

Assessment of soil-gas, soil, and water contamination at the former hospital landfill, Fort Gordon, Georgia, 2009-2010

Soil gas, soil, and water were assessed for organic and inorganic constituents at the former hospital landfill located in a 75-acre study area near the Dwight D. Eisenhower Army Medical Center, Fort Gordon, Georgia, from April to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone of a creek adjacent to the landfill and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Results from the hyporheic-zone assessment in the unnamed tributary adjacent to the study area indicated that total petroleum hydrocarbons and octane were the most frequently detected organic compounds in groundwater beneath the creek bed. The highest concentrations for these compounds were detected in the upstream samplers of the hyporheic-zone study area. The effort to delineate landfill activity in the study area focused on the western 14 acres of the 75-acre study area where the hyporheic-zone study identified the highest concentrations of organic compounds. This also is the part of the study area where a debris field also was identified in the southern part of the 14 acres. The southern part of this 14-acre study area, including the debris field, is steeper and not as heavily wooded, compared to the central and northern parts. Fifty-two soil-gas samplers were used for the July 2010 soil-gas survey in the 14-acre study area and mostly detected total petroleum hydrocarbons, and gasoline and diesel compounds. The highest soil-gas masses for total petroleum hydrocarbons, diesel compounds, and the only valid detection of perchloroethene were in the southern part of the study area to the west of the debris field. However, all other detections of total petroleum hydrocarbons greater than 10 micrograms and diesel greater than 0.04 micrograms, and all detections of the combined mass of benzene, toluene, ethylbenzene, and xylene were found down slope from the debris field in the central and northern parts of the study area. Five soil-gas samplers were deployed and recovered from September 16 to 22, 2010, and were analyzed for organic compounds classified as chemical agents or explosives. Chloroacetophenones (a tear gas component) were the only compounds detected above a method detection level and were detected at the same location as the highest total petroleum hydrocarbons and diesel detections in the southern part of the 14-acre study area. Composite soil samples collected at five locations were analyzed for 35 inorganic constituents. None of the inorganic constituents exceeded the regional screening levels. One surface-water sample collected in the western end of the hyporheic-zone study area had a trichlorofluoromethane concentration above the laboratory reporting level and estimated concentrations of chloroform, fluoranthene, and isophorone below laboratory reporting levels.

Georgia

Applying GORE-TEX technology for rapid contaminant assessments at Fort Gordon, Georgia

The U.S. Geological Survey, in cooperation with the U.S. Department of the Army at Fort Gordon, Georgia, deployed GORE1 adsorbent samplers along creeks and floodplains to rapidly assess potential contamination at abandoned facilities and in adjacent surface water. The samplers provide screening-level data to determine the presence or absence of volatile organic compounds, semi-volatile organic compounds, and polycyclic aromatic hydrocarbons and were deployed in saturated creek and floodplain sediments adjacent to four abandoned waste-disposal/warfare-training sites. Fuelrelated compounds, not solvents, are the most prevalent organic compounds detected along segments of McCoys Creek adjacent to the 19th Street landfill; South Prong Creek adjacent to the South Prong Creek waste-disposal area; an unnamed tributary to Butler Creek adjacent to the old hospital landfill; and the Brier Creek floodplain adjacent to the Patterson anti-tank range. All 37 samplers deployed in these assessments had detections of total petroleum hydrocarbons ranging from just above 3 (laboratory method detection level) to 344 micrograms per liter. Detections of octane that ranged from 1 to 7.6 micrograms per liter were common in all assessments, except for South Prong Creek. Calculated concentrations of benzene are at or just above the National Primary Drinking Water Standard maximum contaminant level for all samplers deployed in the floodplain at the Patterson anti-tank range. The highest calculated concentration of a specific fuel-related compound was for toluene collected at one sampling site on McCoys Creek adjacent to the 19th Street landfill, but the concentration was below the National Primary Drinking Water Standard. These results are being used by Fort Gordon environmental compliance personnel to decide if further assessments are needed at these abandoned waste-disposal/warfare-training sites

Georgia