Geology ReportsSearch

Geology topics

Forest P. Lyford

Publications and source records attributed to Forest P. Lyford.

13 recordsLinked to original sources

Simulated ground-water flow for a pond-dominated aquifer system near Great Sandy Bottom Pond, Pembroke, Massachusetts

A ground-water flow simulation for a 66.4-square-mile area around Great Sandy Bottom (GSB) Pond (105 acres) near Pembroke, Massachusetts, was developed for use by local and State water managers to assess the yields for public water supply of local ponds and wells for average climatic and drought conditions and the effects of water withdrawals on nearby water levels and streamflows. Wetlands and ponds cover about 30 percent of the study area and the aquifer system is dominated by interactions between ground water and the ponds. The three largest surface-water bodies in the study area are Silver Lake (640 acres), Monponsett Pond (590 acres), and Oldham Pond (236 acres). The study area is drained by tributaries of the Taunton River to the southwest, the South and North Rivers to the northeast, and the Jones River to the southeast. In 2002, 10.8 million gallons per day of water was exported from ponds and 3.5 million gallons per day from wells was used locally for public supply. A transient ground-water-flow model with 69 monthly stress periods spanning the period from January 1998 through September 2003 was calibrated to stage at GSB Pond and nearby Silver Lake and streamflow and water levels collected from September 2002 through September 2003. The calibrated model was used to assess hydrologic responses to a variety of water-use and climatic conditions. Simulation of predevelopment (no pumping or export) average monthly (1949-2002) water-level conditions caused the GSB Pond level to increase by 6.3 feet from the results of a simulation using average 2002 pumping for all wells, withdrawals, and exports. Most of this decline can be attributed to pumping, withdrawals, and exports of water from sites away from GSB Pond. The effects of increasing the export rate from GSB Pond by 1.25 and 1.5 times the 2002 rate were a lowering of pond levels by a maximum of 1.6 and 2.8 feet, respectively. Simulated results for two different drought conditions, one mild drought similar to that of 1979-82 and a more severe drought similar to that of 1963-66, but with current (2002) pumping, were compared to results for average monthly recharge conditions (1949-2002). Simulated mild drought conditions showed a reduction of GSB Pond level of about 1.3 feet and a lower streamflow of about 1.7 percent in the nearby stream. Simulated severe drought conditions reduced the pond level at GSB Pond by almost 7 feet and lowered streamflow by about 37 percent. Varying cranberry-irrigation practices had little effect on simulated GSB Pond water levels, but may be important in other ponds. The model was most sensitive to changes in areal recharge. An increase and decrease of 22 percent in recharge produced changes in the GSB Pond water level of +1.4 feet and -2.4 feet, respectively. The accuracy of simulation results was best in the central portion of the study area in the immediate location of GSB Pond. The model was developed with the study-area boundary far enough away from the GSB Pond area that the boundary would have minimal effect on the water levels in GSB Pond, nearby ponds, and the underlying aquifer system. The model is best suited for use by local and State water managers to assess the effects of different withdrawal scenarios for wells and ponds near GSB Pond and for general delineation of areas contributing recharge to wells and ponds in the vicinity of GSB Pond. The model in its current form may not be well suited to detailed analyses of water budgets and flow patterns for parts of the study area farther from GSB Pond without further investigation, calibration, and data collection.

Scientific Investigations Report

Delineation of water sources for public-supply wells in three fractured-bedrock aquifer systems in Massachusetts

Fractured-bedrock aquifer systems in West Newbury, Maynard, and Paxton, Massachusetts, were studied to advance methods of data collection and analysis for delineating contributing areas to public-supply wells completed in fractured rock and for determining the effects of pumping on streams and wetlands. Contributing areas, as defined for this study, include all areas through which ground water flows from recharge areas to wells. In West Newbury, exploratory public-supply wells at two locations were completed in phyllite of the Eliot Formation. Aquifer testing indicated that subhorizontal and steeply dipping fractures that parallel two sets of foliation form elongated transmissive zones in the bedrock aquifer near the two well locations and also form a vertical hydraulic connection to surficial materials consisting of till at one location and marine clay at the other location. Recharge to bedrock is largely through a thin veneer of till over bedrock, but leakage through thick drumlin tills also recharges bedrock. Simulated contributing areas for the three supply wells pumped at a combined rate of 251 gallons per minute encompass about 1.3 square miles and extend to ground-water divides within most of a subbasin of the Artichoke River. Pumping likely would reduce streamflow in the Artichoke River subbasin by approximately the pumping rate. Pumping is likely to affect wetland areas underlain by till near the wells because of the vertical hydraulic connection to surficial materials. In Maynard, three exploratory public-supply wells were completed in coarse-grained schist of the Nashoba Formation. Aquifer testing indicated that a dense network of fractures in bedrock forms a laterally extensive transmissive zone in bedrock that is well connected vertically to surficial materials consisting of sandy till, lacustrine silts, sand and gravel, and wetland deposits. The simulated contributing area for the three supply wells pumped at a combined rate of 780 gallons per minute encompasses about 1.8 square miles of the Fort Pond Brook drainage area. Pumping likely would reduce streamflow in Fort Pond Brook by about the same amount as the pumping rate, and wetland-water levels within a 2,000-foot radius from the wells are likely to be lowered below the land surface by pumping. In Paxton, three existing supply wells are completed in granofels and schist of the Paxton and Littleton Formations. Aquifer testing demonstrated that a shallow bedrock well completed to a depth of 150 feet is closely connected hydraulically to overlying till. Two deep wells, however, receive much of their water from fractures at depths below 500 feet. Ground-water flow in bedrock appears to be mostly through parting fractures along a foliation set that dips gently (10 degrees) eastward. These parting fractures at depth are poorly connected vertically to shallow bedrock

Water-Resources Investigations Report

Volatile Organic Compounds, Specific Conductance, and Temperature in the Bottom Sediments of Mill Pond, Ashland, Massachusetts, April 2001

A plume of volatile organic compounds in ground water extends northward from the former Nyanza Property in Ashland, Massachusetts, and discharges into the Sudbury River and the upstream end of Mill Pond. A network of polyethylene-membrane passive-vapor-diffusion samplers was installed in February 2001 to help define the lateral extent of the plume under the pond, including an area vegetated by wetland herbs, sedges, and shrubs. Chlorobenzene and trichloroethene were detected with passive-vapor-diffusion samplers at five locations in the bottom sediments of the southern part of the approximate one acre of vegetated area in Mill Pond. Vapor concentrations of chlorobenzene ranged from 178 to 2,210 parts per billion by volume, and vapor concentrations of trichloroethene ranged from 20 to 96 parts per billion by volume. Chlorobenzene also was detected in one sediment-pore-water sample extracted with a push-point sampler in this area; the concentration was 25 micrograms per liter. Toluene was detected with passive-vapor-diffusion samplers at three sites in the open pond area north of the vegetated areas. Vapor concentrations of toluene ranged from 20 to 90 parts per billion by volume. Specific conductance and temperature of sediment-pore waters were measured at selected sampling sites in Mill Pond to examine their possible associations with the presence of volatile organic compounds. Temperature in the sediment-pore water also was measured to convert vapor concentrations of volatile organic compounds collected with diffusion samplers to equivalent water concentrations. These equivalent water concentrations were then to be compared with water concentrations collected with a push-point sampler. Because of the limited detections of volatile organic compounds at sites where water samples were collected and where specific conductance and temperature were measured, these potential associations and conversions could not be assessed.

Open-File Report

Guidance on the use of passive-vapor-diffusion samplers to detect volatile organic compounds in ground-water-discharge areas, and example applications in New England

Polyethylene-membrane passive-vapor-diffusion samplers, or PVD samplers, have been shown to be an effective and economical reconnaissance tool for detecting and identifying volatile organic compounds (VOCs) in bottom sediments of surface-water bodies in areas of ground-water discharge. The PVD samplers consist of an empty glass vial enclosed in two layers of polyethylene membrane tubing. When samplers are placed in contaminated sediments, the air in the vial equilibrates with VOCs in pore water. Analysis of the vapor indicates the presence or absence of VOCs and the likely magnitude of concentrations in pore water.

Maine, Vermont, New Hampshire, Massachusetts, Penn

Distribution of selected volatile organic compounds determined with water-to-vapor diffusion samplers at the interface between ground water and surface water, Centredale Manor site, North Providence, Rhode Island, September 1999

Volatile organic compounds are present in soils and ground water at the Centredale Manor Superfund Site in North Providence, Rhode Island. In September 1999, water-to-vapor diffusion samplers were placed in the bottom sediments of waterways adjacent to the site to identify possible contaminated ground-water discharge areas. The approximate12-acre site is a narrow stretch of land between the eastern bank of the Woonasquatucket River, downstream from the U.S. Route 44 bridge and a former mill raceway. The samplers were placed along a 2,250-foot reach of the Woonasquatucket River, in the former mill raceway several hundred feet to the east and parallel to the river, and in a cross channel between the river and former mill raceway. Volatile organic compounds were detected in 84 of the 104 water-to-vapor diffusion samplers retrieved. Trichloroethylene and tetrachloro-ethylene were the principal volatile organic compounds detected. The highest vapor concentrations measured for these two chemicals were from diffusion samplers located along an approximate 100-foot reach of the Woonasquatucket River about 500 feet downstream of the bridge; here trichloroethylene and tetrachloroethylene vapor concentrations ranged from about 2,000 to 180,000 and 1,600 to 1,400,000 parts per billion by volume, respectively. Upstream and downstream from this reach and along the former mill raceway, trichloroethylene and tetrachloroethylene vapor concentrations from the diffusion samples were generally less than 100 parts per billion by volume. Along the lower reaches of the river and mill raceway, however, and in the cross channel, vapor concentrations of trichloroethylene exceeded 100 parts per billion by volume and tetrachloroethylene exceeded 1,000 parts per billion by volume in several diffusion samples. Although diffusion sample vapor concentrations are higher than water concentrations in surface waters and in ground water, and they should only be interpreted qualitatively as relative values, these values provide important information as to potential discharge areas of contaminants.

Rhode Island

Field tests of polyethylene-membrane diffusion samplers for characterizing volatile organic compounds in stream-bottom sediments, Nyanza Chemical Waste Dump Superfund site, Ashland, Massachusetts

A plume of volatile organic compounds (VOCs) in ground water extends from the Nyanza Chemical Waste Dump Superfund site in Ashland, Massachusetts, northward toward a mill pond on the Sudbury River and eastward toward the Sudbury River and former mill raceway downstream from the mill pond. Polyethylene-membrane water-to-vapor (vapor) and water-to-water (water) diffusion samplers were installed January 1999 in bottom sediments along the Sudbury River and former mill raceway in a pilot study to determine if vapor samplers would be useful in this setting for delineating a plume of contaminants in ground water near the river and raceway, to evaluate equilibration time for vapor-diffusion samplers, and to determine if diffusion samplers might be an alternative to seepage meters (inverted steel drums) and sediment sampling for evaluating concentrations of VOCs in bottom sediments. Of five tested compounds (benzene, trichloroethene, toluene, tetrachloroethene, and chlorobenzene), chlorobenzene and trichloroethene were most frequently detected in vapor from vapor-diffusion samplers. The distribution of VOCs was generally consistent with a previously mapped plume of contaminants in ground water. The field evaluation of equilibration times for vapor-diffusion samplers was inconclusive because of changing hydrologic conditions that may have affected concentrations of VOCs, possible variations in concentrations ofVOCs over short distances, and imprecise sampling and analytical methods. The limited data, however, indicated that equilibration may require 3 weeks or more in some settings. VOCs detected in samples from water-diffusion samplers and their concentrations were comparable to results from seepage meters, and VOCs detected in vapor-diffusion samplers correlated with VOCs detected in water-diffusion samplers. These results indicate that either vapor-or water-diffusion samplers would serve as an economical alternative to seepage meters for sampling of VOCs in pore water from stream-bottom sediments. Results from diffusion samplers correlated poorly with results from sediment samples, partly because of high quantitation limits for chemical analyses of sediments. In general, results from the diffusion samplers better represented the distribution of VOCs than the results from the sediment samples. This pilot study indicates that diffusion samplers are an economical means of identifying 'hotspots' for contaminants in bottom sediments and can provide insights on transport pathways for contaminants near surface-water bodies. After establishing equilibration times for a particular site, diffusion samplers also may be useful for studying variations in concentrations of VOCs over short distances, variations with time and changing hydrologic conditions, and processes such as chemical transformations by biodegradation and exchanges between surface water and ground water in the hyporheic zone.

Water-Resources Investigations Report

Estimated hydraulic properties for the surficial- and bedrock-aquifer system, Meddybemps, Maine

Analytical and numerical-modeling methods were used to estimate hydraulic properties of the aquifer system underlying the Eastern Surplus Company Superfund Site in Meddybemps, Maine. Estimates of hydraulic properties are needed to evaluate pathways for contaminants in ground water and to support evaluation and selection of remediation measures for contaminated ground water at this site. The hydraulic conductivity of surficial materials, determined from specific-capacity tests, ranges from 17 to 78 feet per day for wells completed in coarse-grained glaciomarine sediments, and from about 0.1 to 1.Ofoot per day for wells completed in till. The transmissivity of fractured bedrock determined from specific-capacity tests and aquifer tests in wells completed in less than 200 feet of bedrock ranges from about 0.09 to 130 feet squared per day. Relatively high values of transmissivity at the south end of the study area appear to be associated with a high-angle fracture or fracture zone that hydraulically connects two wells completed in bedrock. Transmissivities at six low-yielding (less than 0.5 gallon per minute) wells, which appear to lie within a poorly transmissive block of the bedrock, are consistently in a range of about 0.09 to 0.5 foot squared per day. The estimates of hydraulic conductivity and transmissivity in the southern half of the study area are supported by results of steady-state calibration of a numerical model and simulation of a 24-hour pumping test at a well completed in bedrock. Hydraulic conductivity values for the surficial aquifer used in the model were 30 feet per day for coarse-grained glaciomarine sediments, 0.001 to 0.01 foot per day for fine-grained glaciomarine sediments, and 0.1 to 0.5 foot per day for till. As part of model calibration, a relatively transmissive zone in the surficial aquifer was extended beyond the hypothesized extent of coarse-grained sediments eastward to the Dennys River. Hydraulic conductivity values used for bedrock in the model ranged from 3x10 -4 to 1.5 feet per day. The highest values were in the fracture zone that hydraulically connects two wells and apparently extends to the Dennys River. The transmissivity of bedrock used in the model ranged from 0.03 to 150 feet squared per day, with the majority of the bedrock transmissivities set at 0.3 foot squared per day. Numerical modeling results indicated that a very low ratio of vertical hydraulic conductivity to thickness (1x10 -9 days -l ) was required to simulate a persistent cone of depression near a residential well that lies in the previously identified poorly transmissive block of bedrock.

Maine

Potential for advection of volatile organic compounds in ground water to the Cochato River, Baird & McGuire Superfund Site, Holbrook, Massachusetts, March and April 1998

In March and April 1998, a network of water-to-vapor diffusion samplers was installed along the Cochato River at the Baird & McGuire Superfund Site in Holbrook, Massachusetts, where a plume of volatile organic compounds (VOCs) is present in ground water. The purpose of installing the sampler network was to determine if VOCs were present in river-bottom sediments while a ground-water extraction system was operating and after the system had been shut down for two weeks. Water-to-water diffusion samplers placed at selected locations provided supplemental information about concentrations of VOCs in pore water in the river-bottom sediments. Water levels in piezometers and river stage were measured concurrently to determine if ground water was discharging to the river. Benzene, toluene, ethylbenzene and xylenes (BTEX compounds) were detected in water-tovapor and water-to-water diffusion samplers located in the area where the plume is known to pass beneath the river for both pumping and nonpumping conditions. Concentrations of total BTEX compounds in water-to-vapor diffusion samplers ranged from non-detect upriver and downriver from the plume area to greater than 200 parts per million by volume in the plume area. Concentrations of total BTEX compounds were not significantly different for pumping than for non-pumping conditions. Concentrations of total BTEX compounds in water-to-water diffusion samplers ranged from non-detect to 680 micrograms per liter. The limited number of water-to-water diffusion samplers did not indicate that concentrations were higher for pumping or non-pumping conditions. Trichloroethylene and tetrachloroethylene also were detected in water-to-vapor diffusion samplers downriver from the area where the BTEX compounds were detected. Water levels in four piezometers were consistently higher than the river stage, indicating an upward hydraulic gradient and ground-water discharge to the river. The concentrations of VOCs in riverbottom sediments and the upward hydraulic gradients observed indicate that contaminants from the Baird & McGuire ground-water plume were discharging to the Cochato River during the study period for both pumping and non-pumping conditions.

Massachusetts

Distribution of Trichloroethylene and Geologic Controls on Contaminant Pathways near the Royal River, McKin Superfund Site Area, Gray, Maine

Vapor-diffusion samplers were used in the autumn of 1997 to determine the lateral extent and distribution of concentrations of a trichloroethylene (TCE) plume in the ground-water discharge area near the McKin Superfund Site, Gray, Maine. Analyses of vapor in the samplers identified a plume about 800 feet wide entering the river near Boiling Springs, an area of ground-water discharge on the flood plain of the Royal River. The highest observed concentration of TCE in vapor was in an area of sand boils on the western bank of the river and about 200 feet downstream from Boiling Springs. Previous studies showed that most of the TCE load in the river originated in the area of the sand boils. In general, highest concentrations were observed on the western side of the river on the upgradient side of the plume, but TCE also was detected at numerous locations in the center and eastern bank of the river. The TCE plume discharges to the river where fine-grained glaciomarine sediments of the Presumpscot Formation are absent and where coarse-grained facies of buried glaciomarine fan deposits provide a pathway for ground-water flow. Based on results of analyses of vapor-diffusion samples and other previous studies, the plume appears to pass under and beyond the river near Boiling Springs and along the river for about 300 feet downstream from the sand boils. A coarse-grained, organic-rich layer at the base of the alluvial flood plain sediments is confined by overlying fine-grained alluvial sediments and may provide a conduit for ground-water leaking upward from buried glaciomarine fan deposits.

Water-Resources Investigations Report

Hydrologic indices for nontidal wetlands

Two sets of hydrologic indices were developed to characterize the water-budget components of nontidal wetlands. The first set consisted of six water-budget indices for input and output variables, and the second set consisted of two hydrologic interaction indices derived from the water-budget indices. The indices then were applied to 19 wetlands with previously published water-budget data. Two trilinear diagrams for each wetland were constructed, one for the three input indices and another for the three output indices. These two trilinear diagrams then were combined with a central quadrangle to form a Piper-type diagram, with data points from the trilinear diagrams projected onto the quadrangle. The quadrangle then was divided into nine fields that summarized the water-budget information. Two quantitative "interaction indices" were calculated from two of the six water-budget indices (precipitation and evapotranspiration). They also were obtained graphically from the water-budget indices, which were first projected to the central quadrangle of a Piper-type diagram from the flanking trilinear plots. The first interaction index (l) defines the strength of interaction between a wetland and the surrounding ground- and surface-water system. The second interaction index (S) defines the nature of the interaction between the wetland and the surrounding ground- and surface-water system (source versus sink). Evaluation of these indices using published wetland water-budget data illustrates the usefulness of the technique.

Wetlands

Bibliography on ground water in glacial-aquifer systems in the Northeastern United States

The U.S. Geological Survey established the Regional Aquifer-System Analysis (RASA) program to evaluate major interconnected aquifers or groups of aquifers that share similar characteristics within a region. One of the objectives of the Northeastern Glacial RASA is to provide information on the occurrence and quality of ground water in glacial deposits in ten States: Maine, New Hampshire, Vermont, Massachusetts, Rhode Island, Connecticut, New York, Ohio, Pennsylvania, and New Jersey. To help meet the objectives of the RASA program, an automated bibliographic data base was developed. The data base contains references to ground-water resources of glacial-aquifer systems in the ten States listed above. This bibliography contains more than 700 ground-water related references that date from 1839 through 1984. The bibliography lists books, journal articles, conference proceedings, government and other technical reports, theses, and maps. Unpublished manuscripts, publications in press, newspaper articles, and book reviews are omitted from the bibliography.

Circular

Valley fill in the Roswell-Artesia area, New Mexico

Drill samples from 225 water and oil wells in an area 70 miles long and 20 miles wide in the Roswell-Artesia area, southeastern New Mexico were examined. A thickness map and a saturated thickness map of the valley-fill sediments were constructed. Maximum depth of valley fill is about 300 feet in large closed depressions near Roswell, Hagerman, and Artesia. The depressions were formed by the solution of carbonates and evaporites that underlie the fill. Maximum saturated thickness is about 250 feet in depressions near Hagerman and Artesia and about 300 feet in a depression near Roswell.

Open-File Report