Geology ReportsSearch

Geology topics

E.M. Paul

Publications and source records attributed to E.M. Paul.

3 recordsLinked to original sources

Summary statistics and graphical comparisons of specific conductance, temperature, and dissolved oxygen data, Buffalo Bayou, Houston, Texas, April 1986-March 1991

Buffalo Bayou is the major stream that drains the Houston, Texas, metropolitan area. The U.S. Geological Survey has provided specific conductance, temperature, and dissolved oxygen data to the City of Houston for three sites along a 7.7-mile reach of Buffalo Bayou since 1986. Summary statistics and graphical comparisons of the data show substantial variability in the properties during 1986-91. Specific conductance ranged from about 100 microsiemens per centimeter at 25 degrees Celsius at each of the three sites to 17,100 microsiemens per centimeter at 25 degrees Celsius at the most downstream site, at the headwaters of the Houston Ship Channel. Water temperatures ranged from 5 to 33 degrees Celsius. Temperatures were very similar at the two upstream sites and slightly warmer at the most downstream site. Dissolved oxygen ranged from zero at the most downstream site to 11.7 milligrams per liter at the most upstream site.

Texas

Hydrologic data for urban studies in the Houston metropolitan area, Texas, 1984

Hydrologic investigations of urban watersheds in Texas were begun by the U.S. Geological Survey in 1954. Studies are now in progress in the Austin and Houston areas, and have been completed in the Dallas-Fort Worth and San Antonio areas. The U.S. Geological Survey, in cooperation with the city of Houston, began studies in the Houston metropolitan area in 1964. The program was expanded in 1968 to include collection of water-quality data. The objectives of the Houston urban-hydrology study are as follows: To determine, on the basis of historical data and hydrologic analyses, the magnitude and frequency of flood peaks and flood volumes; To determine the effect of urban development on flood peaks and volumes; and To ascertain the variation in water quality for different flow conditions and different seasons. This report, the twenty-first and last scheduled in a series of reports published annually, is primarily applicable to objective 2. The report presents hydrologic data collected in the Houston urban area for the 1984 water year (October 1, 1983 to September 30, 1984). A report by Johnson and Sayre (1973) utilized records collected from 1965 to 1969 to study the effects of urbanization on floods in the Houston area. That report also summarized various basin parameters. A report by Waddell, Massey, and Jennings (1979) presented data on runoff from the Houston area and computed concentrations and loads of selected water-quality constituents discharged to Galveston Bay. The study utilized a variation of the "STORM" model developed by the Hydrologic Engineering Center of the U.S. Army Corps of Engineers. A report prepared by Liscum and Massey (1980) presented a technique for estimating the magnitude and frequency of floods in the Houston area from drainage areas, bank-full conveyance, and percentage of urban development. A definition of terms related to streamflow, water quality, and other hydrologic data, as used in this report, are defined in "U.S. Geological Survey, Water-resources data for Texas, water year 1984, volume 2."

Texas

Effects on water quality due to flood-water detention by Barker and Addicks Reservoirs, Houston, Texas

The Barker and Addicks Reservoirs, located about 16 miles west of Houston, Texas, provide flood-detention storage for storm runoff. Of interest are the water-quality characteristics in the study area and changes in water quality during detention. Study area sampling sites were selected upstream along Buffalo Bayou for Barker Reservoir and on Bear Creek and Langham Creek for Addicks Reservoir, within the reservoirs, near the reservoir outflows, and below the confluence of each reservoir outflow at the streamflow station Buffalo Bayou near Addicks. Flow data were available at all sites except in the reservoirs. Analyses of samples collected during both low flow and storm runoff show that, in general, the waters of the study area were low in mineralization, but the aesthetics of the water was a problem. The inorganic constituents, trace metals, and pesticides rarely exceeded maximum contaminant levels recommended by the U.S. Environmental Protection Agency for public supply using 1976 and 1977 criteria for primary and secondary standards. All species of nutrients, except ammonia nitrogen and phosphorus, almost always were below the recommended maximum contaminant levels. Phosphorus almost always exceeded these levels. Aesthetic problems are evident. Large values of suspended solids, turbidity, and color were common. Small dissolved-oxygen values commonly occurred in the reservoirs. Possible bacterial problems are indicated because coliformbacteria densities exceeded recommended levels in about 25 percent of the samples. The effects of the reservoirs on the water-quality characteristics of storm runoff were analyzed using three approaches. The first approach was a comparison of the discharge-weighted average values of nine selected constituents at each streamflow-gaging station during four storms. Reservoir effects on the quality of runoff detained 1 to 4 days in the two reservoirs were inconsistent. However, the reservoirs consistently had an effect on the water quality of runoff that was detained the longest (more than 8 days). Biochemical oxygen demand, suspended solids, turbidity, color, total nitrogen, and total organic carbon discharge-weighted average values were consistently smaller after flowing through the reservoirs. Dissolved solids and total phosphorus values were consistently larger after flowing through the reservoirs. The second approach was an analysis of the means of the discharge-weighted average values computed for the four hydrologic events using the Student t-test. Statistical results Indicate that reservoir detention significantly reduced suspended solids (the mean decreased from 178 milligrams per liter at the Inflows to 105 milligrams per liter at the outflows) and turbidity (the mean decreased from 119 nephelometrlc turbidity units at the inflows to 66 nephelometric turbidity units at the outflows). The third approach was a comparison at each site of the mean, maximum, and minimum values computed for seven constituents that did not correlate with discharge. These constituents or properties of water were temperature, pH, dissolved oxygen, dissolved oxygen percent saturation, total-coliform bacteria, fecal-conform bacteria, and fecal-streptococci bacteria. The only consistent water-quality changes observed were with the three bacteria groups, which were decreased by flood-water detention.

Texas