The hydrothermal system at Newberry Volcano, Oregon

Results of recent geological and geophysical studies at Newberry Volcano have been incorporated into conceptual and numerical models of a magma-based hydrothermal system. Numerical simulations begin with emplacement of a small magma body, the presumed source of silicic eruptions at Newberry that began about 10,000 B.P., into a thermal regime representing 100,000 years of cooling of a large underlying intrusion. Simulated flow patterns and thermal histories for three sets of hypothetical permeability values are compatible with data from four geothermal drill holes on the volcano. Meteoric recharge cools the caldera-fill deposits, but thermal water moving up a central conduit representing a permeable volcanic vent produces temperatures close to those observed in drill holes within the caldera. Meteoric recharge from the caldera moves down the flanks and creates a near-isothermal zone that extends several hundred meters below the water table, producing temperature profiles similar to those observed in drill holes on the flanks. The temperatures observed in drill holes on the flanks are not influenced by the postulated Holocene magma body. The elevated temperature gradients measured in the lower portions of these holes may be related to the cumulative effect of older intrusions. The models also indicate that meteoric recharge to the deep hydrothermal system probably originates within or near the caldera. Relatively low fluid velocities at depth suggest that at least a significant fraction of the thermal fluid may be very old.

Journal of Geophysical Research Solid Earth↗

Flow testing of the Newberry 2 research drillhole, Newberry volcano, Oregon

A 20 hour flow test of the Newberry 2 research drillhole at Newberry Volcano produced about 33,000 kilograms of fluid. The flow rate declined from about 0.8 kilograms per sec to less than 0.3 kilograms per sec during the course of the test. The mass ratio of liquid water to vapor was about 3:2 at the separator and stayed fairly constant throughout the test. The vapor phase was about half steam and half CO2 by weight. The average enthalpy of the steam/water mixture at the separator was about 1 ,200 kilojoules per kilogram. Because of the low flow rate and the large temperature gradient into the surrounding rocks, heat loss from the wellbore was high; a simple conductive model gives overall losses of about 1,200 kilojoules per kilogram of H2O produced. The actual heat loss may have been even higher due to convective effects, and it is likely that the fluid entering the bottom of the wellbore was largely or entirely steam and CO2. (Author 's abstract)

Water-Resources Investigations Report↗

CHEMISTRY OF LOW-TEMPERATURE GEOTHERMAL WATERS AT KLAMATH FALLS, OREGON.

Chemical and isotopic analyses of well discharges indicate that in the aquifer mixing occurs between shallow cold groundwater containing 2. 0 TU tritium and a deeper tritium-free thermal groundwaer at 100 to 120 degree C. This deeper water apparently results from the mixing of old, tritium-free cold groundwater and deep thermal groundwater at about 190 degree C and 120 mg/kg Cl. The temperature and chlorinity of the deep thermal water are based on SO//4-isotope and silica geothermometers and chloride and silica mixing models.

Conference Paper↗

Analysis and interpretation of data obtained in tests of the geothermal aquifer at Klamath Falls, Oregon

Water with temperatures to 130 C occurs in an extensive, heterogeneous aquifer at depths of a few hundred to nearly 2,000 feet. Chemical and isotopic analyses suggest that 190 C water mixes with cooler recharge water in a ratio of about 2 to 3 in zone within and beneath the aquifer. The water spreads from a fault zone and is tapped for space heating by more than 450 wells over a 2 square-mile area. Data obtained during a 50-day pumping and reinjection test in July and August, 1983, were fitted to theoretical double-porosity type curves. Predictions of water-level changes were made for two hypothetical pumping and reinjection schemes. It was determined that reinjection can generally offset declines due to pumping, although water levels will decline near pumped wells and will rise near injection wells. Tracer tests confirmed the double-porosity behavior of the aquifer. Discharge from thermal wells averages about 540 gallons per minute and heat discharge is about 18 x 10 to the 12th power British Thermal Units per year. Down-hole heat exchangers discharge about 13 x 10 to the 10th power British Thermal Units per year. Additional development probably is feasible. (USGS)

Water-Resources Investigations Report↗

Hydrology of the Newberry Volcano caldera, Oregon

Precipitation in the Newberry Caldera is very nearly in balance with evaporation, evapotranspiration, and streamflow. Calcium, magnesium, and bicarbonate ions predominate in the more dilute ground and surface water. Thermal waters from springs and wells have concentrations of 900 milligrams per liter or more and are characterized by high concentrations of sodium and sulfate. Attempts to account for the origin of the hot springs on the basis of mixing relations and isotopic analyses were inconclusive; the springs may represent mixtures of thermal and nonthermal water which are altered by gases rising from sources beneath the caldera floor. Annual recharge to deep aquifers beneath the caldera is probably in the range 2,500 to 6,500 acre-feet. Observations in a Geological Survey drill hole suggest that part of the water may flow to aquifers at depths as much as 1,900 feet beneath the caldera floor. Potential recharge to a postulated geothermal reservoir probably is extremely small. (USGS)

Water-Resources Investigations Report↗

Hydrologic reconnaissance of the geothermal area near Klamath Falls, Oregon

Geothermal phenomena observed in the vicinity of Klamath Falls include hot springs with temperatures that approach 204°F (96 o C) (the approximate boiling temperature for the altitude), steam and water wells with temperatures that exceed 212°F (100°C), and hundreds of warm-water wells with temperatures mostly ranging from 68° to 95°F (20° to 35°C). Although warm waters are encountered by wells throughout much of the 350 square miles (900 square kilometers) of the area studied, waters with temperatures exceeding 140°F (60°C) are confined to three relatively restricted areas, the northeast part of the City of Klamath Falls, Olene Gap, and the southwest flank of the Klamath Hills. The hot waters are located near, and are presumably related to, major fault and fracture zones of the Basin and Range type. The displaced crustal blocks are composed of basaltic flow rocks and pyroclastics of Miocene to Pleistocene age, and of sediments and basalt flows of the Yonna Formation of Pliocene age. Dip-slip movement along the high-angle faults may be as much as 6,000 feet (1,800 meters) at places. Shallow ground water of local meteoric origin moves through the upper 1,000 to 1,500 feet (300 to 450 meters) of sediments and volcanic rocks at relatively slow rates. A small amount of ground water, perhaps 100,000 acre feet (1.2 x 10 8 cubic meters) per year, leaves the area in flow toward the southwest, but much of the ground water is discharged as evapotranspiration within the basin. Average annual precipitation on 7,317 square miles (18,951 square kilometers) of land surface near Klamath Falls is estimated to be 18.16 inches (461 millimeters), of which between 12 and 14 inches (305 and 356 millimeters) is estimated to be lost through evapotranspiration. Within the older basaltic rocks of the area, hydraulic conductivities are greater than in the shallow sediments, and ground water may move relatively freely parallel to the northwest-southeast structural trend. Recharge to the geothermal systems probably occurs as water, in the deeper basalt rocks, penetrating downward along the extensive fracture zones that transect the area. Shallow meteoric water that is assumed to be the source of the thermal waters has low dissolved-solids concentrations generally dominated by calcium and bicarbonate. During its passage through the geothermal reservoir, the water gains dissolved solids in amounts up to about 900 milligrams per liter. Sodium and sulfate become the dominant ions. Chloride concentrations remain relatively low, and silica concentrations increase from an average of about 35 milligrams per liter to about 100 milligrams per liter. Both cation ratios and silica concentrations in the hot waters indicate that reservoir temperatures are relatively low. The estimate arrived at in this study for the minimum reservoir temperature is 130°C. Silica concentrations are probably more reliable than cation ratios for estimates of reservoir temperatures for these waters. Other chemical indicators, including oxygen and deuterium isotopes, are consistent in indicating that reservoir temperatures are probably not much greater than the minimum estimate. Temperature distributions and heat flows in the shallow rocks of the area are strongly influenced by convective flow of water. Most observed temperature gradients and estimated heat flows are believed to be unreliable as indicators of conditions in or directly above the thermal reservoir. Some evidence from temperature profiles suggests, however, that heat flow in the Lower Klamath Lake basin is about 1.4 microcalories per square centimeter per second (1.4 HFU), a value that is near the minimum expected for the Basin and Range province. The net thermal flux discharged from springs and wells in the area is estimated to be on the order of 2 x 10 6 calories per second. Discharge by thermal waters into the shallow ground-water system beneath land surface may be many times this amount. Reportedly, at present only about 1,300 calories per second of geothermal heat is being put to beneficial use in the area. A conceptual model of the geothermal system at Klamath Falls suggests that most of the observed phenomena result from transport of heat in a convective hot-water system closely related to the regional fault system. Temperatures at shallow depths are elevated above normal both by convective transport and by blockage of heat flow in sediments of low thermal conductivities. Circulation of meteoric water to depths of 10,000 to 14,000 feet (3,000 to 4,300 meters) could account for the temperatures that probably exist in the thermal reservoir, assuming temperature gradients of 30° to 40°C per kilometer in a crustal zone of normal conductive heat flow. Circulation to shallower depths may be sufficient to warm the water to the required temperatures assuming the more likely conditions of convective transport of heat and the insulating effect of overlying sediments. Heat contents in the shallow hot-water system (<3 kilometers depth) are probably in the range 12 x 10 18 calories to 36 x 10 18 calories. The geothermal resource at Klamath Falls may, therefore, be one of the largest in the United States.