Geology Reports⌕ Search

Geology topics

Charles R. Hutt

Publications and source records attributed to Charles R. Hutt.

At least 19 recordsLinked to original sources

Albuquerque Seismological Laboratory strategic vision

This circular presents a strategic outlook for the U.S. Geological Survey (USGS) Albuquerque Seismological Laboratory (ASL) for the next 10 years (2026–36). The ASL is a USGS field office in the Geological Hazards Science Center that operates portions of the Advanced National Seismic System and the Global Seismographic Network and focuses on fundamental research for instrumentation testing and data quality. The strategic outlook is categorized into two types of tasks: “Foundational Tasks” and “Aspirational Tasks.” Foundational Tasks are those that maintain the laboratory’s basic operations and services, including regional and global seismic monitoring, improving data quality, and providing instrument testing and support. A suite of Aspirational Tasks is also articulated; these can be considered priority targets of ASL that could improve ASL’s seismic monitoring capabilities and mission. Such tasks include improvements to remote stations, testing capabilities of nonseismic geophysical instruments, detection threshold monitoring, rapid aftershock deployments, and expanding seismic monitoring networks. This report was written with input from the USGS Geological Hazards Science Center, the USGS Earthquake Hazards Program (EHP), and colleagues with an interest in the work done by the ASL. Although the details of these tasks may change, this document can provide guidance on the overarching tasks at the ASL from 2026 to 2036 and an overview of the various components of the ASL and how they fit into the EHP and the Global Seismographic Network Program.

Circular↗

Global seismic networks operated by the U.S. Geological Survey

The U.S. Geological Survey (USGS) Global Seismographic Network (GSN) Program operates two thirds of the GSN, a network of state‐of‐the‐art, digital seismological and geophysical sensors with digital telecommunications. This network serves as a multiuse scientific facility and a valuable resource for research, education, and monitoring. The other one third of the GSN is funded by the National Science Foundation (NSF), and the operations of this component are overseen by EarthScope. This collaboration between the USGS, EarthScope, and NSF has allowed for the development and operations of the GSN to be a truly multiuse network that provides near real‐time open access data, facilitating fundamental discoveries by the Earth science community, supporting the earthquake hazards mission of the USGS, benefitting tsunami monitoring by the National Oceanic and Atmospheric Administration, and contributing to nuclear test monitoring and treaty verification. In this article, we describe the installation and evolution of the seismic networks operated by the USGS that ultimately led to the USGS portion of the GSN (100 stations under network codes IU, IC, and CU) as they are today and envision technological advances and opportunities to further improve the utility of the network in the future. This article focuses on the USGS‐operated component of the GSN; a companion article on the GSN stations funded by the NSF and operated by the Cecil and Ida Green Institute of Geophysics and Planetary Physics, Scripps Institution of Oceanography, University of California at San Diego by Davis et al. (2023) appears in this volume.

Seismological Research Letters↗

A collection of historic seismic instrumentation photographs at the Albuquerque Seismological Laboratory

The Albuquerque Seismological Laboratory (ASL) has preserved a collection of photographs of seismographic equipment, stations, and drawings used by the United States Coast and Geodetic Survey (USC&GS) in the early-to-mid-twentieth century. The photographs were transferred to ASL from the US Department of Commerce building in Washington DC after ASL became established as a USC&GS facility for seismological research and instrumentation testing in 1961. The photographs were variously used in publications to document USC&GS activities or used internally to document instrument installation, operation, and/or components. The historic photograph collection is made up of hundreds of photographs that were originally printed in the 1930s and 1940s. Our hope is that the archival of these records, as well as brief descriptions about their significance, will help preserve some of the knowledge about seismological advances in the United States during this time period. We provide digital scans of the complete ASL historic photo collection and discuss the historical context of select images in the Electronic Supplement of this document.

Seismological Research Letters↗

The Albuquerque Seismological Lab WWSSN film chip preservation project

From 1961 to 1996, the Albuquerque Seismological Laboratory (ASL) installed and operated the World‐Wide Standardized Seismograph Network (WWSSN). Each station within the network consisted of three Benioff short‐period sensors and three Sprengnether Press‐Ewing long‐period sensors along with recording, timing, and calibration equipment. Approximately 3.7 million single‐day record film chips were created from station records (paper seismograms) covering the period from 1962 to 1978. Two almost complete copies of these film chips are still known to exist at the ASL and at the Lamont–Doherty Earth Observatory (LDEO) as well as a couple of partial sets in other locations. To better preserve the data on these film chips, a project to scan the film chips and to make these scans available through the Incorporated Research Institutions for Seismology (IRIS) was started by W. H. K. Lee. The initial focus was on scanning film chips from a collection of specific earthquakes and nuclear events as well as complete scans of a number of reference stations. However, additional scans containing seismograms useful for climate studies were also completed. As part of this report, we cataloged all of the scanned WWSSN film chips with the hope that it serves as useful documentation as to what film chips have been scanned and of the location of the scans themselves at the IRIS‐Data Management Center (DMC) archive page (see Data and Resources ).

Seismological Research Letters↗

Seismic sensors record a hurricane’s roar

The instruments installed at Global Seismographic Network (GSN) stations were designed to record Earth’s vibrations, but they sometimes pick up sound waves from unexpected sources. For example, newly installed infrasound sensors at a station on Puerto Rico recorded the passage of Hurricane Maria on 20 September 2017.

Eos, Earth and Space Science News↗

Effects of thermal variability on broadband seismometers: Controlled experiments, observations, and implications

Isolating seismic instruments from temperature fluctuations is routine practice within the seismological community. However, the necessary degree of thermal stability required in broadband installations to avoid generating noise or compromising the fidelity in the seismic records is largely unknown and likely application dependent. To quantify the temperature sensitivity of seismometers over a broad range of frequencies, we artificially induced local temperature changes on three different models of seismometers to measure the effect of thermal variations on seismometer output. We found that diurnal temperature changes above 0.002°C root mean square (rms) showed significant changes in velocity and acceleration output in comparison to thermally stable reference measurements. We also found that sensor incoherent self‐noise increased with temperature variation; these increases in noise can be modeled as 1 / f "> 1 / f noise (pink noise), and are unlikely to be easily corrected for. These experimental results are compared with the data from Incorporated Research Institutions for Seismology (IRIS) U.S. Geological Survey (USGS) Global Seismographic Network (GSN) station TUC (Tucson, Arizona). This station is well instrumented with temperature sensors and has three different broadband seismometers, each of which uses a different method of thermal isolation. We show that the water bricks and borehole installations give ample temperature attenuation to thermally isolate seismometers from diurnal thermal variability that would compromise seismic data. We find that seismometer installations that provide thermal stability below 0.002°C rms could help to improve long‐period vertical seismic data across the GSN by decreasing temperature‐driven 1 / f "> 1 / f noise.

Bulletin of the Seismological Society of America↗

Detection and characterization of pulses in broadband seismometers

Pulsing - caused either by mechanical or electrical glitches, or by microtilt local to a seismometer - can significantly compromise the long‐period noise performance of broadband seismometers. High‐fidelity long‐period recordings are needed for accurate calculation of quantities such as moment tensors, fault‐slip models, and normal‐mode measurements. Such pulses have long been recognized in accelerometers, and methods have been developed to correct these acceleration steps, but considerable work remains to be done in order to detect and correct similar pulses in broadband seismic data. We present a method for detecting and characterizing the pulses using data from a range of broadband sensor types installed in the Global Seismographic Network. The technique relies on accurate instrument response removal and employs a moving‐window approach looking for acceleration baseline shifts. We find that pulses are present at varying levels in all sensor types studied. Pulse‐detection results compared with average daily station noise values are consistent with predicted noise levels of acceleration steps. This indicates that we can calculate maximum pulse amplitude allowed per time window that would be acceptable without compromising long‐period data analysis.

Bulletin of the Seismological Society of America↗

Characterizing local variability in long‐period horizontal tilt noise

Horizontal seismic data are dominated by atmospherically induced tilt noise at long periods (i.e., 30 s and greater). Tilt noise limits our ability to use horizontal data for sensitive seismological studies such as observing free earth modes. To better understand the local spatial variability of long‐period horizontal noise, we observe horizontal noise during quiet time periods in the Albuquerque Seismological Laboratory (ASL) underground vault using four small‐aperture array configurations. Each array comprises eight Streckeisen STS‐2 broadband seismometers. We analyze the spectral content of the data using power spectral density and magnitude‐squared coherence (γ2‐coherence). Our results show a high degree of spatial variability and frequency dependence in the long‐period horizontal wavefield. The variable nature of long‐period horizontal noise in the ASL vault suggests that it might be highly local in nature and not easily characterized by simple physical models when overall noise levels are low, making it difficult to identify locations in the vault with lower horizontal noise. This variability could be limiting our ability to apply coherence analysis for estimating horizontal sensor self‐noise and could also complicate various indirect methods for removing long‐period horizontal noise (e.g., collocated rotational sensor or microbarograph).

New Mexico↗

Broadband seismic noise attenuation versus depth at the Albuquerque Seismological Laboratory

Seismic noise induced by atmospheric processes such as wind and pressure changes can be a major contributor to the background noise observed in many seismograph stations, especially those installed at or near the surface. Cultural noise such as vehicle traffic or nearby buildings with air handling equipment also contributes to seismic background noise. Such noise sources fundamentally limit our ability to resolve earthquake‐generated signals. Many previous seismic noise versus depth studies focused separately on either high‐frequency ( &gt; 1 &#x2009;&#x2009; Hz "> > 1 Hz ) or low‐frequency ( &lt; 0.05 &#x2009;&#x2009; Hz "> < 0.05 Hz ) bands. In this study, we use modern high‐quality broadband (BB) and very broadband (VBB) seismometers installed at depths ranging from 1.5 to 188 m at the Albuquerque Seismological Laboratory to evaluate noise attenuation as a function of depth over a broad range of frequencies (0.002–50 Hz). Many modern seismometer deployments use BB or VBB seismometers installed at various depths, depending on the application. These depths range from one‐half meter or less in aftershock study deployments, to one or two meters in the Incorporated Research Institutions for Seismology Transportable Array (TA), to a few meters (shallow surface vaults) up to 100 m or more (boreholes) in the permanent observatories of the Global Seismographic Network (GSN). It is important for managers and planners of these and similar arrays and networks of seismograph stations to understand the attenuation of surface‐generated noise versus depth so that they can achieve desired performance goals within their budgets as well as their frequency band of focus. The results of this study will assist in decisions regarding BB and VBB seismometer installation depths. In general, we find that greater installation depths are better and seismometer emplacement in hard rock is better than in soil. Attenuation for any given depth varies with frequency. More specifically, we find that the dependence of depth will be application dependent based on the frequency band and sensitive axes of interest. For quick deployments (like aftershock studies), 1 m may be deep enough to produce good data, especially when the focus is on vertical data where temperature stability fundamentally limits the low‐frequency noise levels and little low‐frequency data will be used. For temporary (medium‐term) deployments (e.g., TA) where low cost can be very important, 2–3 m should be sufficient, but such shallow installations will limit the ability to resolve low‐frequency signals, especially on horizontal components. Of course, one should try for maximum burial depth within the budget when there is interest in using the data for low‐frequency applications. For long‐term deployments like the permanent observatories of the GSN and similar networks, 100–200 m depth in hard rock is desirable to achieve lowest noise, although 30–60 m may be acceptable.

Bulletin of the Seismological Society of America↗

Noise reduction in long‐period seismograms by way of array summing

Long‐period (>100 s period) seismic data can often be dominated by instrumental noise as well as local site noise. When multiple collocated sensors are installed at a single site, it is possible to improve the overall station noise levels by applying stacking methods to their traces. We look at the noise reduction in long‐period seismic data by applying the time–frequency phase‐weighted stacking method of Schimmel and Gallart (2007) as well as the phase‐weighted stacking (PWS) method of Schimmel and Paulssen (1997) to four collocated broadband sensors installed in the quiet Albuquerque Seismological Laboratory underground vault. We show that such stacking methods can improve vertical noise levels by as much as 10 dB over the mean background noise levels at 400 s period, suggesting that greater improvements could be achieved with an array involving multiple sensors. We also apply this method to reduce local incoherent noise on horizontal seismic records of the 2 March 2016 M w 7.8 Sumatra earthquake, where the incoherent noise levels at very long periods are similar in amplitude to the earthquake signal. To maximize the coherency, we apply the PWS method to horizontal data where relative azimuths between collocated sensors are estimated and compared with a simpler linear stack with no azimuthal rotation. Such methods could help reduce noise levels at various seismic stations where multiple high‐quality sensors have been deployed. Such small arrays may also provide a solution to improving long‐period noise levels at Global Seismographic Network stations.

Bulletin of the Seismological Society of America↗

Potential improvements in horizontal very broadband seismic data in the IRIS/USGS component of the Global Seismic Network

The Streckeisen STS‐1 has been the primary vault‐type seismometer used in the over‐150‐station Global Seismographic Network (GSN). This sensor has long been known for its outstanding vertical, very long‐period (e.g., >100&thinsp;&thinsp;s period), and low‐noise performance, although the horizontal long‐period noise performance is less well known. The STS‐1 is a limited, important resource, because it is no longer made or supported by the original manufacturer. We investigate the incoherent noise of horizontal‐component sensors, where coherent signals among sensors have been removed, giving an upper bound on the self‐noise of both the STS‐1 and STS‐2 horizontal components. Our findings suggest that a well‐installed STS‐2 could potentially produce data with similar or better incoherent noise levels to that of a horizontal‐component STS‐1. Along with our experimental investigation, we compare background noise levels for a calendar year at Incorporated Research Institutions for Seismology/U.S. Geological Survey network stations, which comprise approximately two‐thirds of the GSN, with collocated STS‐1 and STS‐2 seismometers. The use of an STS‐2‐class of sensor (flat to velocity to 120 s period) to acquire low‐frequency data in surface‐vault installations would allow network operators to focus more attention on improving vertical data. In order to deal with the difference in instrument response shapes between the two instruments, we detail two different time‐domain filters that would allow users to convert broadband STS‐2 data into very broadband data with a response similar to that of an STS‐1 (flat to velocity to 360 s period). We conclude that the complexity of the current primary horizontal vault sensors in the GSN may not be necessary until we are better able to isolate surface horizontal sensors from various noise sources.

Seismological Research Letters↗

Self-noise models of five commercial strong-motion accelerometers

Strong‐motion accelerometers provide onscale seismic recordings during moderate‐to‐large ground motions (e.g., up to tens of m/s 2 peak). Such instruments have played a fundamental role in improving our understanding of earthquake source physics (Bock etal. , 2011), earthquake engineering (Youd et al. , 2004), and regional seismology (Zollo et al. , 2010). Although strong‐motion accelerometers tend to have higher noise levels than high‐quality broadband velocity seismometers, their higher clip‐levels provide linear recordings at near‐field sites even for the largest of events where a collocated broadband sensor would no longer be able to provide onscale recordings (Clinton and Heaton, 2002). Recently, the seismological community has begun to make use of strong‐motion accelerometer data even in the absence of large ground motions (e.g., Tibuleac et al. , 2011). The noise floor of the instruments often limits the usefulness of strong‐motion accelerometer data in such studies, because it obscures first arrivals or can make the traces dominated by noise. When a strong‐motion accelerometer is deployed in a quiet setting, the noise floors of the digitizer and the accelerometer tend to dominate the other noise sources (Cauzzi and Clinton, 2013). This situation is unlike that using broadband sensors, in which site conditions are typically the largest contributing source of noise in seismic data, especially at long periods (Wilson et al. , 2002). With the widespread deployment of strong‐motion accelerometers recorded on high resolution digitizers, it is now possible to get continuous high‐rate acceleration data in which the digitizer noise is not the dominant noise source (Cauzzi and Clinton, 2013). To better characterize the noise of a number of commonly deployed accelerometers in a standardized way, we conducted noise measurements on five different models of strong‐motion accelerometers. Our study was limited to traditional accelerometers (Fig. 1) and is in no way exhaustive.

Seismological Research Letters↗

Uncertainty estimates in broadband seismometer sensitivities using microseisms

The midband sensitivity of a seismic instrument is one of the fundamental parameters used in published station metadata. Any errors in this value can compromise amplitude estimates in otherwise high-quality data. To estimate an upper bound in the uncertainty of the midband sensitivity for modern broadband instruments, we compare daily microseism (4- to 8-s period) amplitude ratios between the vertical components of colocated broadband sensors across the IRIS/USGS (network code IU) seismic network. We find that the mean of the 145,972 daily ratios used between 2002 and 2013 is 0.9895 with a standard deviation of 0.0231. This suggests that the ratio between instruments shows a small bias and considerable scatter. We also find that these ratios follow a standard normal distribution ( R 2 &thinsp;=&thinsp;0.95442), which suggests that the midband sensitivity of an instrument has an error of no greater than &plusmn;6 % with a 99 % confidence interval. This gives an upper bound on the precision to which we know the sensitivity of a fielded instrument.

Journal of Seismology↗

Seismometer Self-Noise and Measuring Methods

Seismometer self-noise is usually not considered when selecting and using seismic waveform data in scientific research as it is typically assumed that the self-noise is negligibly small compared to seismic signals. However, instrumental noise is part of the noise in any seismic record, and in particular, at frequencies below a few mHz, the instrumental noise has a frequency-dependent character and may dominate the noise. When seismic noise itself is considered as a carrier of information, as in seismic interferometry (e.g., Chaput et al. 2012 ), it becomes extremely important to estimate the contribution of instrumental noise to the recordings.

Book chapter↗

A brief test of the Hewlett-Packard MEMS seismic accelerometer

Testing was performed on a prototype of Hewlett-Packard (HP) Micro-Electro-Mechanical Systems (MEMS) seismic accelerometer at the U.S. Geological Survey’s Albuquerque Seismological Laboratory. This prototype was built using discrete electronic components. The self-noise level was measured during low seismic background conditions and found to be 9.8 ng/√Hz at periods below 0.2 s (frequencies above 5 Hz). The six-second microseism noise was also discernible. The HP MEMS accelerometer was compared to a Geotech Model GS-13 reference seismometer during seismic noise and signal levels well above the self-noise of the accelerometer. Matching power spectral densities (corrected for accelerometer and seismometer responses to represent true ground motion) indicated that the HP MEMS accelerometer has a flat (constant) response to acceleration from 0.0125 Hz to at least 62.5 Hz. Tilt calibrations of the HP MEMS accelerometer verified that the flat response to acceleration extends to 0 Hz. Future development of the HP MEMS accelerometer includes replacing the discreet electronic boards with a low power application-specific integrated circuit (ASIC) and increasing the dynamic range of the sensor to detect strong motion signals above one gravitational acceleration, while maintaining the self-noise observed during these tests.

Open-File Report↗

World-Wide Standardized Seismograph Network: a data users guide

The purpose of this report, which is based on an unpublished draft prepared in the 1970s, is to provide seismologists with the information they may need to use the WWSSN data set as it becomes available in a more easily accessible and convenient format on the Internet. The report includes a description of the WWSSN network, station facilities, operations and instrumentation, a derivation of the instrument transfer functions, tables of transfer functions, a description of calibration techniques, and a description of a method used to determine important instrument constants using recorded calibration data.

Open-File Report↗

Obtaining changes in calibration-coil to seismometer output constants using sine waves

The midband sensitivity of a broadband seismometer is one of the most commonly used parameters from station metadata. Thus, it is critical for station operators to robustly estimate this quantity with a high degree of accuracy. We develop an in situ method for estimating changes in sensitivity using sine‐wave calibrations, assuming the calibration coil and its drive are stable over time and temperature. This approach has been used in the past for passive instruments (e.g., geophones) but has not been applied, to our knowledge, to derive sensitivities of modern force‐feedback broadband seismometers. We are able to detect changes in sensitivity to well within 1%, and our method is capable of detecting these sensitivity changes using any frequency of sine calibration within the passband of the instrument.

Bulletin of the Seismological Society of America↗