Geology ReportsSearch

Geology topics

Carl E. Orazio

Publications and source records attributed to Carl E. Orazio.

22 records · Page 2Linked to original sources

Use of the semipermeable membrane device as an in situ sampler of waterborne bioavailable PCDD and PCDF residues at sub-parts-per-quadrillion concentrations

Semipermeable membrane devices (SPMDs) were used to passively sample aqueous polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in Bayou Meto, AR. The two sites were upstream and downstream from the confluence with a tributary that delivers PCDDs and PCDFs to the Bayou. Following dialysis, cleanup, and fractionation, four replicate 17-9 SPMD samples from each site were analyzed by GUMS, and four were evaluated by H411E bioassay. Traces of only OCDD and HpCDDs were detected in samples from the upstream site. The four samples from below the tributary contained averages of 1550 ± 80 pg of 2,3,7,8-TCDD, 1640 ± 80 pg of 2,3,7,8-TCDF, and lesser quantities of other congeners. The TCDD equivalents obtained by bioassay of replicate SPMD samples agreed well with results obtained by GC/MS. The quantities of 2,3,7,8- TCDD and 2,3,7,8-TCDF sequestered by SPMDs at the downstream site were used to estimate the aqueous concentrations for both compounds as 2 pg/L.

Environmental Science & Technology

Toxicological and chemical screening of Antarctica sediments: Use of whole sediment toxicity tests, microtox, mutatox and semipermeable membrane devices (SPMDs)

Eight whole sediment samples from Antarctica (four from Winter Quarters Bay and four from McMurdo Sound) were toxicologically and chemically evaluated. Also, the influence of ultraviolet radiation on the toxicity and bioavailability of contaminants associated with the sediment samples was assessed. The evaluations were accomplished by use of a 10-day whole sediment test with Leptocheirus plumulosus , Microtox®, Mutatox® and semipermeable membrane devices (SPMDs). Winter Quarters Bay sediments contained about 250 ng g −1 (dry weight) total PCBs and 20 μg g −1 total PAHs. These sediments elicited toxicity in the Microtox test and avoidance and inhibited burrowing in the L. plumulosus test. The McMurdo Sound sediment samples contained only trace amounts of PCBs and no PAHs, and were less toxic in both the L. plumulosus and Microtox tests compared to the Winter Quarters Bay sediments. The sediments from McMurdo Sound apparently contained some unidentified substance which was photolytically modified to a more toxic form. The photolytic modification of sediment-associated contaminants, coupled with the polar ozone hole and increased incidence of ultraviolet radiation could significantly increase hazards to Antarctic marine life.

Marine Pollution Bulletin

Use of the semipermeable membrane device (SPMD) to sample polycyclic aromatic hydrocarbon pollution in a lotic system

Relative concentrations of aqueous polycyclic aromatic hydrocarbons (PAH) were investigated in an urban creek. Samples were obtained at five sites within a 600-m segment of the creek that is critical habitat for an endangered species of fish. the sampling technique entailed immersion of semipermeable membrane devices (SPMDs) in the water for intervals as long as 64 d. SPMDs are passive, in situ , mtegrative samplers of bioavailable (truly dissolved) PAH and other hydrophobic organic contaminants. Two point sources of PAH to the 600-m segment of the creek were differentiated. Aqueous concentrations were found to wane dramatically over the relatively short section of the creek between the point sources. All samples were almost devoid of alkyl-substituted PAH, indicating that the ultimate sources were probably of pyrogenic nature.

Polycyclic Aromatic Compounds