Geology ReportsSearch

Geology topics

C.F. Williams

Publications and source records attributed to C.F. Williams.

9 recordsLinked to original sources

Controls on deep direct-use thermal energy storage (DDU-TES) in the Portland Basin, Oregon, USA

Aquifer Thermal Energy Storage is being evaluated as a complementary technology to Deep Direct-Use for the Portland Basin, Oregon, USA. Aquifers can be used to efficiently distribute and store heat for seasonal use. The use of injection-extraction well pairs precludes the need to store or dispose of large volumes of pumped groundwater or to obtain a consumptive groundwater right. Injection temperatures vary seasonally, and well pairs can operate in continuous (single direction of flow) or cyclic (seasonal reversal of flow) modes. The target injection aquifers are the lowest Columbia River Basalt Group interflow zones, which are thermally and hydraulically separated from the overlying aquifer system, minimizing heat loss. A new aquifer thermal energy storage design tool allows assessment of thermal storage and recovery using: (1) system design parameters (e.g., well spacing and pumping rate), (2) thermal and hydraulic property values, and (3) regional groundwater flow rates. In continuous mode, extracted water temperature trends towards the flow-weighted average temperature of injected water over time, with the injected signal significantly lagged and damped. By controlling well spacing and temperature of delivered water (possibly using supplemental heating) continuous mode provides steady reliable warm water to end-users year-round. In cyclic mode, there is an advectively and conductively heated zone near the hot well and a cooled zone near the cool well, with temperatures substantially above and below the flow-weighted average injection temperature, respectively. In cyclic mode, during extraction, water temperatures start high or low, depending on the well, and temperatures trend towards the average injection temperature over the season. For the Columbia River Basalt Group in the Portland Basin, the quantity and quality of heat delivered depends most strongly on operational schedule, well spacing, mode of operation, and heterogeneity of the injection horizon.

Oregon

The USGS national geothermal resource assessment: An update

The U. S. Geological Survey (USGS) is working with the Department of Energy's (DOE) Geothermal Technologies Program and other geothermal organizations on a three-year effort to produce an updated assessment of available geothermal resources. The new assessment will introduce significant changes in the models for geothermal energy recovery factors, estimates of reservoir volumes, and limits to temperatures and depths for electric power production. It will also include the potential impact of evolving Enhanced Geothermal Systems (EGS) technology. An important focus in the assessment project is on the development of geothermal resource models consistent with the production histories and observed characteristics of exploited geothermal fields. New models for the recovery of heat from heterogeneous, fractured reservoirs provide a physically realistic basis for evaluating the production potential of both natural geothermal reservoirs and reservoirs that may be created through the application of EGS technology. Project investigators have also made substantial progress studying geothermal systems and the factors responsible for their formation through studies in the Great Basin-Modoc Plateau region, Coso, Long Valley, the Imperial Valley and central Alaska, Project personnel are also entering the supporting data and resulting analyses into geospatial databases that will be produced as part of the resource assessment.

Conference Paper

Outstanding issues for new geothermal resource assessments

A critical question for the future energy policy of the United States is the extent to which geothermal resources can contribute to an ever-increasing demand for electricity. Electric power production from geothermal sources exceeds that from wind and solar combined, yet the installed capacity falls far short of the geothermal resource base characterized in past assessments, even though the estimated size of the resource in six assessments completed in the past 35 years varies by thousands of Megawatts-electrical (MWe). The U. S. Geological Survey (USGS) is working closely with the Department of Energy's (DOE) Geothermal Research Program and other geothermal organizations on a three-year effort to produce an updated assessment of available geothermal resources. The new assessment will introduce significant changes in the models for geothermal energy recovery factors, estimates of reservoir permeability, limits to temperatures and depths for electric power production, and include the potential impact of evolving Enhanced (or Engineered) Geothermal Systems (EGS) technology.

Conference Paper

Heat flow in the SAFOD pilot hole and implications for the strength of the San Andreas Fault

Detailed thermal measurements have been acquired in the 2.2-km-deep SAFOD pilot hole, located 1.8 km west of the SAF near Parkfield, California. Heat flow from the basement section of the borehole (770 to 2160 m) is 91 mW m-2, higher than the published 74 mW m -2 average for the Parkfield area. Within the resolution of the measurements, heat flow is constant across faults that intersect the borehole, suggesting that fluid flow does not alter the conductive thermal regime. Reanalysis of regional heat flow reveals an increase in heat flow along the SAF northwest of Parkfield. This transition corresponds to a shallowing base of seismicity and a change in fault behavior near the northern terminus of the M6 1966 Parkfield earthquake rupture. The persistence of elevated heat flow in the Coast Ranges to the west appears to rule out frictional heating on the SAF as the source of the SAFOD value.

Geophysical Research Letters

Geologic, water-chemistry, and hydrologic data from multiple-well monitoring sites and selected water-supply wells in the Santa Clara Valley, California, 1999-2003

To better identify the three-dimensional geohydrologic framework of the Santa Clara Valley, lithologic, geologic, geophysical, geomechanical, hydraulic, and water-chemistry data were collected from eight ground-water multiple-well monitoring sites constructed in Santa Clara County, California, as part of a series of cooperative studies between the U.S. Geological Survey and the Santa Clara Valley Water District. The data are being used to update and improve the three-dimensional geohydrologic framework of the basin and to address issues related to water supply, water chemistry, sequence stratigraphy, geology, and geological hazards. This report represents a compilation of data collected from 1999 to 2003, including location and design of the monitoring sites, cone penetrometer borings, geologic logs, lithologic logs, geophysical logs, core analysis, water-chemistry analysis, ground-water-level measurements, and hydraulic and geomechanical properties from wells and core samples. Exploratory cone penetrometer borings taken in the upper 17 to 130 feet at six of the monitoring sites identified the base of Holocene as no deeper than 75 feet in the central confined area and no deeper than 35 feet in the southern unconfined areas of the valley. Generalized lithologic characterization from the monitoring sites indicates about four to six different aquifer units separated by relatively fine-grained units occur within the alluvial deposits shallower than 860 feet deep. Analysis of geophysical logs indicates that coarse-grained units varied in thickness between 10 and 25 feet in the southeastern unconfined area of the valley and between 50 and 200 feet in the south-central and southwestern areas of the valley. Deviations from temperature-gradient logs indicate that the majority of horizontal ground-water flow occurs above a depth of 775 feet in the south central and above 510 feet in the southeastern areas of the valley. Bulk physical properties from more than 1,150 feet of core samples indicate an average primary-wave velocity of about 5,515 feet per second, a bimodal distribution of density between 2.19 and 2.32 grams per cubic centimeter with an average of 2.16 grams per cubic centimeter, and a magnetic susceptibility that generally ranged between 9 and 40 with an average of 22. Water-chemistry data indicate that the ground water in the alluvial aquifers generally is low in total dissolved solids and chloride and of good quality. Isotopic data indicate that water from artificial recharge is present throughout the shallower parts of the aquifer system but may not be present toward the center of the valley. The percentage of water from artificial recharge present in ground water ranges from 0 to 61 percent for water-supply wells. The age of most shallow ground water is less than 2,000 years before present, and the age of deeper ground water is as much as 39,900 years before present, as determined from carbon age dates. Initial water-level data from the multiple-well monitoring sites indicate seasonal water-level fluctuations as great as 60 feet and water-level differences between aquifers as great as 10 feet. The water-level hydrographs indicate different water-level changes and relations between aquifers in different parts of the basin. However, most of these hydrographs indicate the potential for downward water-level gradients, with lower hydraulic heads in the deeper monitoring wells. Hydraulic properties of selected new monitoring wells indicate that horizontal hydraulic conductivities range from 0.1 to 583 feet per day. Hydraulic testing of selected core samples yielded vertical hydraulic conductivity values ranging from 8 x 10-4 to 0.3 feet per day, and effective porosity values ranging from 0.21 to 0.4. Geomechanical properties estimated from one-dimensional consolidation tests of selected core samples resulted in geometric mean inelastic and elastic specific storage values of 1.5 x 10-

Scientific Investigations Report

Geothermal resources of California sedimentary basins

The 2004 Department of Energy (DOE) Strategic Plan for geothermal energy calls for expanding the geothermal resource base of the United States to 40,000 MW of electric power generating potential. This will require advances in technologies for exploiting unconventional geothermal resources, including Enhanced Geothermal Systems (EGS) and geopressured geothermal. An investigation of thermal conditions in California sedimentary basins through new temperature and heat flow measurements reveals significant geothermal potential in some areas. In many of the basins, the combined cooling effects of recent tectonic and sedimentary processes result in relatively low (<60 mW/m2) heat flow and geothermal gradients. For example, temperatures in the upper 3 km of San Joaquin, Sacramento and Ventura basins are typically less than 125??C and do not reach 200??c by 5 km. By contrast, in the Cuyama, Santa Maria and western Los Angeles basins, heat flow exceeds 80 mW/m2 and temperatures near or above 200??C occur at 4 to 5 km depth, which represents thermal conditions equivalent to or hotter than those encountered at the Soultz EGS geothermal site in Europe. Although the extractable geothermal energy contained in these basins is not large relative to the major California producing geothermal fields at The Geysers or Salton Sea, the collocation in the Los Angeles basin of a substantial petroleum extraction infrastructure and a major metropolitan area may make it attractive for eventual geothermal development as EGS technology matures.

Conference Paper

Santa Clara Valley water district multi-aquifer monitoring-well site, Coyote Creek Outdoor Classroom, San Jose, California

The U.S. Geological Survey (USGS), in cooperation with the Santa Clara Valley Water District (SCVWD), has completed the first of several multiple-aquifer monitoring-well sites in the Santa Clara Valley. This site monitors ground-water levels and chemistry in the one of the major historic subsidence regions south of San Jose, California, at the Coyote Creek Outdoor Classroom (CCOC) (fig. 1) and provides additional basic information about the geology, hydrology, geochemistry, and subsidence potential of the upper- and lower-aquifer systems that is a major source of public water supply in the Santa Clara Valley. The site also serves as a science education exhibit at the outdoor classroom operated by SCVWD.

Open-File Report

Characterization of rock thermal conductivity by high-resolution optical scanning

We compared thress laboratory methods for thermal conductivity measurements: divided-bar, line-source and optical scanning. These methods are widely used in geothermal and petrophysical studies, particularly as applied to research on cores from deep scientific boreholes. The relatively new optical scanning method has recently been perfected and applied to geophysical problems. A comparison among these methods for determining the thermal conductivity tensor for anisotropic rocks is based on a representative collection of 80 crystalline rock samples from the KTB continental deep borehole (Germany). Despite substantial thermal inhomogeneity of rock thermal conductivity (up to 40-50% variation) and high anisotropy (with ratios of principal values attaining 2 and more), the results of measurements agree very well among the different methods. The discrepancy for measurements along the foliation is negligible (<1%). The component of thermal conductivity normal to the foliation reveals somewhat larger differences (3-4%). Optical scanning allowed us to characterize the thermal inhomogeneity of rocks and to identify a three-dimensional anisotropy in thermal conductivity of some gneiss samples. The merits of optical scanning include minor random errors (1.6%), the ability to record the variation of thermal conductivity along the sample, the ability to sample deeply using a slow scanning rate, freedom from constraints for sample size and shape, and quality of mechanical treatment of the sample surface, a contactless mode of measurement, high speed of operation, and the ability to measure on a cylindrical sample surface. More traditional methods remain superior for characterizing bulk conductivity at elevated temperature.Three laboratory methods including divided-bar, line-source and optical scanning are widely applied in geothermal and petrophysical studies. In this study, these three methods were compared for determining the thermal conductivity tensor for anisotropic rocks. For this study, a representative collection of 80 crystalline rock samples from the KTB continental deep borehole was used. Despite substantial thermal inhomogeneity of rock thermal conductivity and high anisotropy, measurement results were in excellent agreement among the three methods.

Geothermics

Thermal conductivity of water-saturated rocks from the KTB pilot hole at temperatures of 25 to 300°C

The conductivitites of selected gneiss (two) and amphibolite (one) core samples have been measured under conditions of elevated temperature and pressure with a needle‐probe. Water‐saturated thermal conductivity measurements spanning temperatures from 25 to 300°C and hydrostatic pressures of 0.1 and 34 MPa confirm the general decrease in conductivity with increasing temperature but deviate significantly from results reported from measurements on dry samples over the same temperature range. The thermal conductivity of water‐saturated amphibolite decreases with temperature at a rate approximately 40% less than the rate for dry amphibolite, and the conductivity of water‐saturated gneiss decreases at a rate approximately 20% less than the rate for dry gneiss. The available evidence points to thermal cracking as the primary cause of the more rapid decrease in dry thermal conductivity with temperature. The effects of thermal cracking were also observed in the water‐saturated samples but resulted in a net decrease in room‐temperature conductivity of less than 3%. These results highlight the importance of duplicating in‐situ conditions when determining thermal conductivity for the deep crust.

Geophysical Research Letters