Geology ReportsSearch

Geology topics

Bruce Bernard

Publications and source records attributed to Bruce Bernard.

2 recordsLinked to original sources

Design and evaluation of a field study on the contamination of selected volatile organic compounds and wastewater-indicator compounds in blanks and groundwater samples

The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks. Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples. Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.

Scientific Investigations Report

Quality of ground water in the Biscayne Aquifer in Miami-Dade, Broward, and Palm Beach counties, Florida, 1996-1998, with emphasis on contaminants

The high permeability of the sand and limestone sediments and shallow water table of the Biscayne aquifer make ground water vulnerable to contamination by human activities. To assess potential contamination in the aquifer, untreated ground water was sampled from 30 public-supply wells (40-165 feet deep) in Broward, Miami-Dade, and Palm Beach Counties, 32 shallow wells (10-50 feet deep) in a recently urbanized (residential and light commercial) part of Broward County, and 3 shallow reference wells in Broward County. Results from sample analyses indicate that major ions, pH, dissolved oxygen, nutrients, and trace element concentrations were generally within the range indicative of background concentrations, except for: (1) substantially higher bromide concentrations in water from public-supply wells in southern Miami-Dade County; (2) a few relatively high (greater than 2 milligrams per liter) concentrations of nitrate in water from public-supply wells near agricultural lands in Miami-Dade and southern Broward Counties; and (3) a few relatively high concentrations of arsenic (greater than 10 micrograms per liter) in water from some shallow urban wells near golf courses. Pesticides were detected in every public-supply well, in most of the shallow, urban monitoring wells (78 percent), and in one reference well; however, no pesticide concentration exceeded any drinking-water standard. Fifteen different pesticides or their degradation products were detected. The most frequently detected pesticides were atrazine and tebuthiuron; less frequently detected were the herbicides diuron, fenuron, prometon, metolachlor, simazine, and 2,6-diethylaniline. Volatile organic compounds (VOCs) were detected in most of the public-supply wells (77 percent) and shallow, urban wells (91 percent) and in two of the three reference wells. Thirty-two different VOCs were detected in ground water in the Biscayne aquifer, with cis-1,2-dichloroethene the most frequently detected VOC in the public-supply wells, followed by methyl tert-butyl ether (MTBE), 1,4-dichlorobenzene, and chloroform. Toluene, p-isopropyltoluene, and 1,2,4-trimethylbenzene were the most frequently detected VOCs in the shallow, urban wells. Concentrations of all VOCs were less than the maximum contaminant level (MCL) for public drinking water, except in two samples from public-supply wells near industrialized areas that had vinyl chloride concentrations (3 and 5 micrograms per liter) above the MCL of 1 microgram per liter.

Open-File Report