Geology ReportsSearch

Geology topics

Brendan A. McCarthy

Publications and source records attributed to Brendan A. McCarthy.

6 recordsLinked to original sources

An automatable method for developing preliminary stream crossing designs using lidar and hydraulic modeling in Massachusetts

Upgrading aging and undersized stream crossings (places where culverts and bridges intersect a stream) with replacements designed for aquatic organism passage can improve infrastructure resiliency, geomorphic stability, and maintenance costs. The goal of this work is to develop preliminary culvert designs that convey hydraulic design floods and meet the Massachusetts Stream Crossings Standards for select existing stream crossing sites across Massachusetts. We derive stream and infrastructure data from lidar and other geospatial datasets as input for one-dimensional hydraulic models. Culvert dimensions are iteratively increased until the structures can convey the hydraulic design flood flows with adequate freeboard. The approach was evaluated by comparing lidar-derived designs to designs produced with surveyed data at 30 stream crossings across Massachusetts. The automatable methodology was then applied to 343 stream crossing sites in the Housatonic River watershed in southwestern Massachusetts. For each stream crossing site, preliminary designs were developed to meet the Massachusetts Stream Crossing Standards and convey the 10-, 4-, 2-, and 1-percent annual exceedance probability flood flows. The U.S. Geological Survey StreamStats web application hosts the 3-sided box, 3-sided arch, and pipe culvert preliminary designs. Provided supporting information includes site information, habitat quality assessments, and modeled water surface elevations. The publicly available preliminary designs can be used by municipalities, engineers, and others to evaluate design options, prioritize replacements, and analyze ecological benefits. These designs also may help municipalities pursue grant opportunities and estimate replacement costs prior to investing in field assessments and engineering design.

EarthArXiv

An automated geographic information system-based hydraulic modeling tool for developing preliminary culvert designs for stream crossings in Massachusetts

Introduction Currently (2026), many of the about 25,000 roadway crossing structures over rivers and streams in Massachusetts are undersized. Undersized culverts and bridges can be detrimental to fish and wildlife movement, habitat continuity, and the health of aquatic organisms. Undersized culverts also can lack the resiliency needed to withstand large floods, which could be worsened by potential increases in flood magnitude and frequency due to climate change. Improving culvert and bridge designs for stream crossing projects may improve aquatic organism passage, stream continuity, and resiliency during future floods by decreasing upstream overbank flooding, road flooding and erosion, and degradation of aquatic habitat. The U.S. Geological Survey (USGS), Massachusetts Department of Environmental Protection (MassDEP), and University of Massachusetts Amherst began a series of cooperative studies in July 2019 to develop an automated geographic information system (GIS) hydraulic modeling tool for preliminary culvert designs for stream crossings. The USGS plans to provide preliminary culvert designs in the web-based StreamStats application, which enables municipalities and engineers to view potential designs and related information for stream crossing replacement projects in Massachusetts. This application can (a) provide information on hydrology, hydraulics, and ecological conditions at stream crossing sites, (b) provide users with potential culvert designs to improve aquatic organism passage and flood resiliency, and (c) assist MassDEP in implementing the Massachusetts Wetlands Protection Act regulations for stream crossing projects.

Massachusetts

Water withdrawal and consumption trends for thermoelectric-power plants in the conterminous United States, 2008-2020

Freshwater-using utility-scale thermoelectric (TE) plant water-use estimates were evaluated for annual trends from 2008 to 2020 across the conterminous United States (CONUS) and within hydrologic regions. Overall, TE water withdrawal and consumption trends declined across CONUS by 14,335 and 278 million liters/day, respectively. Decreasing water withdrawal and consumption trends for TE plants are driven largely by switching from coal-fired plants to other generation technologies. TE plant cooling system technology has also changed, with large declining trends for TE plants using once-through cooling systems and small increasing consumption trends for TE plants using recirculating tower cooling systems. Fifteen hydrologic regions have decreasing trends in withdrawals and consumption. The largest decreases are for coal-fired plants using once-through freshwater cooling systems in the Great Lakes and Ohio hydrologic regions. Natural gas combined cycle plants with recirculating tower cooling systems have increased water consumption trends across most of the CONUS hydrologic regions. Some TE plants with recirculating tower or once-through cooling systems withdraw water volumes that on average are close to or exceed average simulated streamflows. Most of these situations occur in the central and eastern U.S., potentially leading to water availability issues among competing water needs, ecosystem impacts from thermal pollution, and power generation constraints.

conterminous United States

Automating physics-based models to estimate thermoelectric-power water use

Thermoelectric (TE) power plants withdraw more water than any other sector of water use in the United States and consume water at rates that can be significant especially in water-stressed regions. Historical TE water-use data have been inconsistent, incomplete, or discrepant, resulting in an increased research focus on improving the accuracy and availability of TE water-use data using modeling approaches. This paper describes and benchmarks new code that was developed to automate and update a physics-based TE water use model that was previously published. Utilizing the automated physics-based model, monthly TE-power water withdrawal and consumption were calculated for a total of 1341 TE power plants for the 2008–2020 historical reanalysis. The updated and automated physics-based thermoelectric-power water-use model provides spatially and temporally relevant TE water-use estimates that are consistent, reproducible, transparent, and can be generated efficiently for water-using, utility-scale TE-power plants across conterminous United States (CONUS).

Environmental Modelling and Software

Assessment of water quality and fecal contamination sources at Hook Pond, East Hampton, New York

Summary The U.S. Geological Survey, in cooperation with the Village of East Hampton, New York, conducted a 1-year study from August 2017 to August 2018 to provide data necessary to improve understanding of the sources of nutrients and pathogens to Hook Pond watershed to allow for possible mitigation or reduction of loads. Chronic eutrophication and recent concern over harmful cyanobacteria in Hook Pond are the result of past and present land uses and a changing climate that have prompted the Village of East Hampton and local businesses to study and remediate factors contributing to the persistent loading of nutrients, organic contaminants, and pathogens. This assessment of Hook Pond, Hook Pond Dreen, and shallow groundwater provides the most comprehensive set of water-quality data to date. Interpretations presented in this study and the data on which they are based can be used to support management decisions, inform and contribute to modeling, and serve as a baseline for future assessments. Results from continuous monitoring of water temperature, specific conductance, and elevation at Hook Pond site 10 (Maidstone Club golf cart bridge), as well as ancillary weather and tidal data from nearby stations, were used to help explain seasonal and storm-related concentration variation of nitrogen, phosphorus, wastewater-indicator compounds, and pathogens. Data collected were also compared to existing historical data. Physicochemical constituents measured on a routine basis throughout the pond and along the tributary showed the spatial variability in water temperature, specific conductance, dissolved oxygen, pH, turbidity, and chlorophyll a and phycocyanin fluorescence. A lakebed survey was compiled based on the year-round sampling throughout the pond for future comparisons. Water-quality data from shallow groundwater at points around Hook Pond and adjacent to Hook Pond Dreen were interpreted and quantified to estimate relative contributions and species of nutrients, wastewater-indicator compounds, and microbial source tracking (MST) markers to base flow. To supplement the continuous water-surface elevation data, a single set of discharge measurements was collected under normal (nonstorm) conditions to better understand the relative contributions and dilution of surface waters by contaminated groundwater. The nutrient and physicochemical data from this study can be used in conjunction with current and future models and decision support tools to guide planned and ongoing restoration efforts, such as dredging to reduce sediment accumulation, opening a pathway to the ocean (which would change the salinity and flow dynamics of the pond and adjacent groundwater), and addressing growing concerns over cyanobacterial blooms, while serving as a baseline for measuring changes resulting from sea-level rise, climate change, and changes in nutrient loading. The microbial source tracking and indicator bacteria results can help direct efforts to reduce runoff and direct contributions of fecal contamination from dogs and waterfowl along Hook Pond Dreen. The results can also be used to assess the current state of wastewater infrastructure surrounding and contributing to Hook Pond Dreen, based on detection of human markers throughout the year and with both Bacteroides and coliphage methods.

New York

Pesticides and their degradates in groundwater reflect past use and current management strategies, Long Island, New York, USA

Long Island, New York, has a mix of urban/suburban to agricultural/horticultural land use and nearly 3 million residents that rely on a sole-source aquifer for drinking water. The analysis of shallow groundwater (<40 m below land surface) collected from 54 monitoring wells across Long Island detected 53 pesticides or pesticide degradates. Maximum concentrations for individual pesticides or pesticide degradates ranged from 3 to 368,000 ng/L. The highest concentrations and most frequent pesticide detections occurred in samples collected from the pesticide management (PM) network, set in an agricultural/horticultural area in eastern Long Island with coordinated pesticide management by state and local agencies. The other two networks (Suffolk and Nassau/Queens) were set in suburban and urban areas, respectively, and had less frequent detections and lower pesticide concentrations than the PM network. Pesticide detections and concentration patterns (herbicide, insecticide, or fungicide) differed among the three networks revealing broad differences in land use. The predominance of fungicides metalaxyl, 1 H -1,2,4-triazole (propiconazole/myclobutanil degradate), and 4-hydroxychlorothalonil (HCTL, chlorothalonil degradate) in samples from the PM network reflects their intensive use in agricultural settings. Total fungicide concentrations in the PM network ranged from <10 to >300,000 ng/L. The widespread detection of imidacloprid and triazine herbicides, simazine and atrazine, reveal a mixture of current and past use pesticides across the Long Island region. Low concentrations (<200 ng/L) of the triazines in the Suffolk and Nassau/Queens networks may reflect a change in land use and application. Acetanilide herbicides and aldicarb have been discontinued for 20 and 40 years, respectively, yet the concentrations of their degradates were among the highest observed in this study. Acetanilide (total concentrations up to 10,000 ng/L) and aldicarb degradates (up to 270 ng/L) are present in the PM network at much lower concentrations than previous Long Island studies and reflect changes in agricultural practices and pesticide management.

New York