Geology Reports⌕ Search

Geology topics

B. L. Markham

Publications and source records attributed to B. L. Markham.

21 records · Page 2Linked to original sources

Data specifications for the Landsat Data Continuity Mission

The National Aeronautics and Space Administration (NASA) plans to procure data from a privately-owned and commercially-operated remote sensing system for the next Landsat Mission, the Landsat Data Continuity Mission (LDCM).Data requirements are documented in an LDCM Data Specification. The specifications require delivery of data covering 250 Landsat scenes on a daily basis. The data are to be acquired in a manner that affords seasonal coverage of the global land mass. Data are required for the heritage reflective Thematic Mapper (TM) spectral bands plus two new bands, a blue band for coastal zone observations and a short wave infrared band for cirrus cloud detection. The specifications do not require thermal data, representing a departure from the TM heritage. The specification also requires data providing a 30 m ground sample distance for each of the spectral bands with the exception of the new cirrus cloud band at 120 m. An absolute uncertainty of 5 percent or less is required for radiometrically corrected LDCM data and the commercial operator is required to deliver data that can be registered to a cartographic projection with an uncertainty of 65 m or less. Procuring data from a commercial operator represents a new approach for the 30-year old Landsat program. The LDCM Data Specification ensures that the procured data provides continuity of the Landsat data stream and advances the mission.

Conference Paper↗

Landsat-7 ETM+ radiometric stability and absolute calibration

Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ??1%, reflective band absolute calibration to better than ??5%, and thermal band absolute calibration to better than ??0.6 K. The ETM+ instrument has been the most stable of any of the Landsat instruments, in both the reflective and thermal channels. To date, the best on-board calibration source for the reflective bands has been the Full Aperture Solar Calibrator, which has indicated changes of at most -1.8% to -2.0% (95% C.I.) change per year in the ETM+ gain (band 4). However, this change is believed to be caused by changes in the solar diffuser panel, as opposed to a change in the instrument's gain. This belief is based partially on ground observations, which bound the changes in gain in band 4 at -0.7% to +1.5%. Also, ETM+ stability is indicated by the monitoring of desert targets. These image-based results for four Saharan and Arabian sites, for a collection of 35 scenes over the three years since launch, bound the gain change at -0.7% to +0.5% in band 4. Thermal calibration from ground observations revealed an offset error of +0.31 W/m 2 sr um soon after launch. This offset was corrected within the U. S. ground processing system at EROS Data Center on 21-Dec-00, and since then, the band 6 on-board calibration has indicated changes of at most +0.02% to +0.04% (95% C.I.) per year. The latest ground observations have detected no remaining offset error with an RMS error of ??0.6 K. The stability and absolute calibration of the Landsat-7 ETM+ sensor make it an ideal candidate to be used as a reference source for radiometric cross-calibrating to other land remote sensing satellite systems.

Conference Paper↗

Landsat-7 ETM+ radiometric calibration: Two years on-orbit

Landsat-7 has been in orbit for 2 years as of April 15, 2001 and operationally providing calibrated data products for 2 years as of June 28, 2001. A radiometric calibration team consisting of scientists and analysts from the Landsat Project Science Office, the Landsat-7 Image Assessment System and four universities evaluates the calibration based on on-board and ground-look (vicarious) calibration methodologies. The results are assembled and compared semi-annually and the calibration parameter files are adjusted as necessary. To date the combined results for the reflective bands have not shown any change from pre-launch values. The pre-launch values continue to be used for data processing, with the uncertainty estimated at less than 5%. In the thermal band, the vicarious calibration results indicated a 0.31 W/m/sup 2/ sr /spl mu/m bias in the calibration. This bias results in the ETM+ derived temperatures being about 3K high. The calibration parameter file was updated October 1, 2000 to remove this bias, however the U.S. Landsat Product Generation System (LPGS) software required modification that was not incorporated until December 20, 2000. All LPGS data products generated since this date have the correct thermal band calibration, regardless of image acquisition date, with uncertainties at approximately the 1% level.

Conference Paper↗