Geology Reports⌕ Search

Geology topics

Anthony J. Bednar

Publications and source records attributed to Anthony J. Bednar.

4 recordsLinked to original sources

The addition of 144Nd atomic mass to routine ICP-MS analysis as a Quick Screening Tool for Approximating Rare Earth Elements (Q-STAR) in natural waters

Rare earth elements (REEs) are a class of critical minerals, all of which can have supply chain vulnerability that impacts economic security. These elements are widely measured in environmental matrices via inductively coupled plasma mass spectrometry (ICP-MS); however, successful quantification can require time-consuming, sample-specific optimization. While a sample-by-sample approach is appropriate for targeted quantification studies, this approach is not suitable for mineral exploration efforts where rapidly screening thousands of samples for the presence of REEs is desired. Here, we demonstrated the use of a Quick Screening Tool for Approximating REEs (Q-STAR) to detect REEs in surface water and groundwater matrices, collected as part of existing environmental studies. A mass-to-charge ratio of 144 ( m / z = 144) was added to an ICP-MS method to screen for REEs in filtered water samples submitted for metals analyses to the U.S. Geological Survey (USGS) National Water Quality Laboratory. We detected the presence of REEs above a reference threshold of 1200 counts per second in 18 % of pre-selected 6626 samples. Using this screened dataset, we mapped estimated dissolved REE concentrations across the United States in relation to ecoregions and underlying geology. Data are constrained to where sample collection took place but nevertheless show estimated aqueous dissolved REE concentrations on a geographic scale that has not yet been studied. To validate Q-STAR, REEs were measured in a USGS standard reference sample, a subset of 88 archived filtered water samples, and in fresh filtered surface water samples. Our targeted analyses demonstrated a strong linear relationship between Q-STAR predicted and measured values in all archived samples for Nd (r 2 = 0.94), and light REEs (LREEs) such as lanthanum (La) (r 2 = 0.93), praseodymium (Pr) (r 2 = 0.94) and samarium (Sm) (r 2 = 0.94). Using Q-STAR screen values, nine field sites were identified and surface water samples recollected to confirm the continued presence of Nd and LREEs. Q-STAR can be used to screen an unlimited number of water samples for the presence of REEs prior to time-intensive and costly quantitative analyses and to generate large REE datasets for further investigation.

Journal of Geochemical Exploration↗

Validation and standardization of SPE and HPLC-UV methods for simultaneous determination of legacy and insensitive munitions

There have been few attempts to consolidate legacy and insensitive munitions analyses. Furthermore, there are no standard methods for insensitive munitions (IM) in tissues, resulting in overlapping methods and supplementary analyses. The goal of the present study was to validate extraction and instrumental methods previously developed and address analytical methodology gaps (missing tissue matrices, combined legacy and IM analysis, and IM compounds). The method encompasses analytes in waters, soils, and tissues. The primary and secondary instrumental methodologies use high performance liquid chromatography-ultraviolet (HPLC-UV) and an alternate LC-mass spectrometry (MS) method, which includes 26 compounds of interest (legacy munitions, IM, IM degradation products , and other munitions compounds). The methods were formally evaluated during a series of double-blind round robin studies including a broad variety of laboratories (Government Department of Defense (DoD), Government non-DoD, ammunition manufacturing, commercial, and academic). The results of these round robin studies were gathered to generate recovery ranges for each of the 26 compounds in each of the matrices. The recovery ranges were subsequently compared with existing recovery ranges for standard explosives analysis, United States Environmental Protection Agency (USEPA) 8330B. The validation study reveals a capable method, which reduces analysis time for IM and legacy munitions analyses.

Environmental Nanotechnology, Monitoring & Managem↗

Interlaboratory comparison of three sediment bioaccumulation tests

Standard bioaccumulation tests are commonly conducted using Macoma nasuta (clam), and Alitta virens (polychaete) for marine tests, and Lumbriculus variegatus (an oligochaete) for freshwater tests. Because the interlaboratory variability associated with these tests is unknown, four experienced laboratories conducted standard 28-day bioaccumulation tests with the above species using sediments contaminated with polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs). Chemical analysis of tissue samples was performed by a single laboratory. The intralaboratory variance among replicates was relatively low for PCB tissue concentrations, with coefficients of variation (CVs) ranging from 9% to 28% for all laboratories and species, with the exception of one laboratory reporting higher variability for L . variegatus (CV = 51%). Intralaboratory variance for PCB tissue concentrations was higher than interlaboratory variance for A. virens and L . variegatus , and the magnitude of difference (MOD) for laboratory means ranged from 1.4 to 2.0 across species. Intralaboratory variability was also low for lipid content, and lipid normalization of PCB and PAH body residues generally had little impact on variability. In addition to variability across bioassay laboratories, analytical variability was evaluated by different laboratories measuring the concentration of PCBs and total lipids in a subsample of tissue homogenate of sediment-exposed test organisms. Variability associated with tissue analysis was higher than bioassay laboratory variability only in tests with L . variegatus . Statistical differences between samples may be observed due to the low intralaboratory variability; however, the biological significance of these differences may be limited because the MOD is low. Considering the MOD when comparing bioaccumulation across treatments accounts for uncertainty related to inherent variability of the test in the interpretation of statistically significant results.

Massachusetts↗

Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory-Arsenic speciation in natural-water samples using laboratory and field methods

Analytical methods for the determination of arsenite [As(III)], arsenate [As(V)], dimethylarsinate (DMA), monomethylarsonate (MMA), and roxarsone in filtered natural-water samples are described. Various analytical methods can be used for the determination, depending on the arsenic species being determined. Arsenic concentration is determined by using inductively coupled plasma-mass spectrometry (ICP-MS) as an arsenic-specific detector for all methods. Laboratory-speciation methods are described that use an ion chromatographic column to separate the arsenic species; the column length, column packing, and mobile phase are dependent on the species of interest. Regardless of the separation technique, the arsenic species are introduced into plasma by eithe rpneumatic nebulization or arsine generation. Analysis times range from 2 to 8 minutes and method detection limits range from 0.1 to 0.6 microgram-arsenic per liter (ug-As/L), 10 to 60 picograms absolute (for a 100-microliter injection), depending on the arsenic species determined and the analytical method used. A field-generation specciation method also is described that uses a strong anion exchange cartridge to separate As(III) from As(V) in the field. As(III) in the eluate and the As(V) in the cartridge extract are determined by direct nebulization ICP-MS. Methylated arsenic species that also are retained on the cartridge will positively bias As(V) results without further laboratory separations. The method detection limit for field speciation is 0.3 ug-As/L. The distribution of arsenic species must be preserved in the field to eliminate changes caused by photochemical oxidation or metal oxyhydroxide precipitation. Preservation techniques, such as refrigeration, the addition of acides, or the additoin of ethylene-diaminetetraacetic acid (EDTA) and the effects of ambient light were tested. Of the preservatives evaluated, EDTA was found to work best with the laboratory- and field-speciation methods for all sample matrices tested. Storing the samples in opaque polytethylene bottles eliminated the effects of photochemical oxidation. The percentage change in As(III):As(V) ratios for an EDTA-preserved acid mine drainage (AMD) sample and ground-water sample during a 3-month period was -5 percent and +3 percent, respectively. The bias and variability of the methods were evaluated by comparing results for total arsenic and As(III), As(V), DMA, and MMA concentrations in ground water, AMD, and surface water. Seventy-one ground-water, 10 AMD, and 24 surface-water samples were analyzed. Concentrations in ground-water samples reached 720 ug-As/L for As(III) and 1080 ug-As/L for As(V); AMD samples reached 12800 ug-As/L for As(III) and 7050 ug-As/L for As(V); and surface-water samples reached 5 ug-As/L for As(III) and As(V). Inorganic arsenic species distribution in the samples ranged from 0 to 90 percent As(III). DMA and MMA were present only in surface-water samples from agricultural areas where the herbicide monosodium methylarsonate was applied; concentrations never exceeded 6 ug-As/L. Statistical analyses indicated that the difference between As(III) and As(V) concentrations for samples preserved with EDTA in opaque bottles and field-speciation results were analytically insignificant at the 95-percent confidence interval. There was no significant difference among the methods tested for total arsenic concentration. Percentage recovery for field samples spiked at 50 ug-As/L and analyzed by the laboratory-speciation method (n=2) ranged from 82 to 100 percent for As(III), 97 to 102 percent for As(V), 90 to 104 percent for DMA, and 81 to 96 percent for MMA; recoveries for samples spiked at 100 ug-As/L and analyzed by the field-speciation method ranged from 102 to 107 percent for As(III) and 105 to 106 percent for As(V). Laboratory-speciation results for Environment Canada reference material SLRS-2 closely matched reported concentrations. Laboratory-speciation metho

Water-Resources Investigations Report↗