Geology ReportsSearch

Geology topics

Ann F. Ardis

Publications and source records attributed to Ann F. Ardis.

12 recordsLinked to original sources

Relations between sinkhole density and anthropogenic contaminants in selected carbonate aquifers in the eastern United States

The relation between sinkhole density and water quality was investigated in seven selected carbonate aquifers in the eastern United States. Sinkhole density for these aquifers was grouped into high (>25 sinkholes/100 km 2 ), medium (1–25 sinkholes/100 km 2 ), or low (<1 sinkhole/100 km 2 ) categories using a geographical information system that included four independent databases covering parts of Alabama, Florida, Missouri, Pennsylvania, and Tennessee. Field measurements and concentrations of major ions, nitrate, and selected pesticides in samples from 451 wells and 70 springs were included in the water-quality database. Data were collected as a part of the US Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program. Areas with high and medium sinkhole density had the greatest well depths and depths to water, the lowest concentrations of total dissolved solids and bicarbonate, the highest concentrations of dissolved oxygen, and the lowest partial pressure of CO 2 compared to areas with low sinkhole density. These chemical indicators are consistent conceptually with a conduit-flow-dominated system in areas with a high density of sinkholes and a diffuse-flow-dominated system in areas with a low density of sinkholes. Higher cave density and spring discharge in Pennsylvania also support the concept that the high sinkhole density areas are dominated by conduit-flow systems. Concentrations of nitrate-N were significantly higher ( p < 0.05) in areas with high and medium sinkhole density than in low sinkhole-density areas; when accounting for the variations in land use near the sampling sites, the high sinkhole-density area still had higher concentrations of nitrate-N than the low sinkhole-density area. Detection frequencies of atrazine, simazine, metolachlor, prometon, and the atrazine degradate deethylatrazine indicated a pattern similar to nitrate; highest pesticide detections were associated with high sinkhole-density areas. These patterns generally persisted when analyzing the detection frequency by land-use groups, particularly for agricultural land-use areas where pesticide use would be expected to be higher and more uniform areally compared to urban and forested areas. Although areas with agricultural land use and a high sinkhole density were most vulnerable (median nitrate-N concentration was 3.7 mg/L, 11% of samples exceeded 10 mg/L, and had the highest frequencies of pesticide detection), areas with agricultural land use and low sinkhole density still were vulnerable to contamination (median nitrate-N concentration was 1.5 mg/L, 8% of samples exceeded 10 mg/L, and had some of the highest frequencies of detections of pesticides). This may be due in part to incomplete or missing data regarding karst features (such as buried sinkholes, low-permeability material in bottom of sinkholes) that do not show up at the scales used for regional mapping and to inconsistent methods among states in karst feature delineation.

Missouri

Factors affecting water quality in selected carbonate aquifers in the United States, 1993-2005

Carbonate aquifers are an important source of water in the United States; however, these aquifers can be particularly susceptible to contamination from the land surface. The U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program collected samples from wells and springs in 12 carbonate aquifers across the country during 1993–2005; water-quality results for 1,042 samples were available to assess the factors affecting ground-water quality. These aquifers represent a wide range of climate, land-use types, degrees of confinement, and other characteristics that were compared and evaluated to assess the effect of those factors on water quality. Differences and similarities among the aquifers were also identified. Samples were analyzed for major ions, radon, nutrients, 47 pesticides, and 54 volatile organic compounds (VOCs). Geochemical analysis helped to identify dominant processes that may contribute to the differences in aquifer susceptibility to anthropogenic contamination. Differences in concentrations of dissolved oxygen and dissolved organic carbon and in ground-water age were directly related to the occurrence of anthropogenic contaminants. Other geochemical indicators, such as mineral saturation indexes and calcium-magnesium molar ratio, were used to infer residence time, an indirect indicator of potential for anthropogenic contamination. Radon exceeded the U.S. Environmental Protection Agency proposed Maximum Contaminant Level (MCL) of 300 picocuries per liter in 423 of 735 wells sampled, of which 309 were drinking-water wells. In general, land use, oxidation-reduction (redox) status, and degree of aquifer confinement were the most important factors affecting the occurrence of anthropogenic contaminants. Although none of these factors individually accounts for all the variation in water quality among the aquifers, a combination of these characteristics accounts for the majority of the variation. Unconfined carbonate aquifers that had high percentages of urban or agricultural land, or a combination of both, had higher concentrations and higher frequency of detections for most of the anthropogenic contaminants than areas with other combinations of land use and degree of aquifer confinement. Redox status is an indicator of more recently recharged water and affects the fate of some contaminants. Median concentrations of nitrate were highest in the Valley and Ridge and Piedmont aquifers and lowest in the Biscayne and Silurian-Devonian/Upper carbonate aquifers. Nitrate concentrations were significantly higher in unconfined aquifers than in confined aquifers and semiconfined/mixed confined aquifers (wells in aquifers with breached confining layers or wells open to both a confined and an unconfined aquifer). Water recharged after 1953 had significantly higher concentrations of nitrate than water recharged prior to 1953. Redox status was also a key factor affecting nitrate concentrations; in recently recharged waters, samples in oxic waters had significantly higher concentrations of nitrate than anoxic waters, regardless of land use in the area around the well. Samples from 54 wells (5 percent) exceeded the U.S. Environmental Protection Agency MCL of 10 mg/L for nitrate in drinking water. Most of the samples exceeding the drinking-water standard (52 samples, or 5 percent) were in domestic supply wells in agricultural areas. The Piedmont and Valley and Ridge aquifers had the largest number of samples (45) exceeding the MCL; in the remaining aquifers only 9 samples had concentrations of nitrate that exceeded the MCL (about 1 percent). None of the water recharged prior to 1953 and only a single sample from a confined aquifer had nitrate concentrations that exceeded 10 mg/L as N. Wells were sampled for a minimum of 47 pesticides. Detection frequencies and comparisons varied depending on the assessment level used. At least 1 of the 47 pesticides was detected at 510 (50 percent) of the 1,027 sites where pesticide data were available using the ‘all detections’ assessment level—that is, including any quantified detection as well as any estimated values where the compound was definitively detected. Multiple pesticides were frequently detected in a sample of water from a site; 34 percent of the samples had two to five pesticides detected in the same sample, and 4 percent of the samples had six or more pesticides detected. Dieldrin was detected at 20 sites, 9 of which were from either domestic or public supply wells, at a concentration above the Health-Based Screening Level (HBSL) of 0.002 µg/L. Diazinon was detected at a concentration greater than the HBSL of 1 µg/L at a single site, which was also a domestic supply well. These are the only samples where a pesticide exceeded a human-health benchmark. The most frequently occurring pesticide compounds were four herbicides—atrazine, simazine, metolachlor, and prometon—and deethylatrazine, a degradate of atrazine. These pesticides typically were detected at concentrations that were less than 10 percent of a human-health benchmark. Of the four frequently occurring pesticides, only samples for atrazine (3 percent) and simazine (0.1 percent) had concentrations that exceeded 10 percent of the human-health benchmark; most of these cases were in agricultural areas. It is important to note, however, that the most frequently occurring pesticide degradate compound—deethylatrazine—has no human-health benchmark. Using a common assessment level of 0.01 µg/L, four of the aquifers—Biscayne, Mississippian, Piedmont, and Valley and Ridge—had at least one of these five compounds detected in more than 30 percent of the wells sampled. These four aquifers, along with the Ordovician, Ozark Plateaus, and Prairie du Chien aquifers were the aquifers or aquifer systems that had concentrations of pesticides that exceeded 10 percent of a human-health benchmark. Water recharged after 1953 had a significantly higher percentage of detections of pesticides than water recharged before 1953, and water from unconfined aquifers had a significantly higher percentage of detections of pesticides than water from confined or semiconfined/mixed confined aquifers. Water from sites in unconfined aquifers, where land use was agricultural or urban, accounted for the vast majority of detections of pesticides. Dissolved oxygen concentration was positively related to pesticide occurrence, which likely reflects the positive association between dissolved oxygen concentration and recently recharged water. Water samples were collected for analysis of VOCs at 793 sites—154 samples were analyzed for 54 VOCs from 1993 through 1995 and 639 samples were analyzed for 86 VOCs from 1996 through 2005. Twenty percent of samples contained one or more VOCs at concentrations greater than or equal to 0.2 µg/L (159 of 793 samples). The aquifers with the highest percentage of samples containing one or more VOCs were the Castle Hayne (about 41 percent of samples) and Biscayne aquifers (34 percent). The most frequently detected VOCs were chloroform, tetrahydrofuran, tetrachloroethene (PCE), toluene, acetone, ethylmethylketone, methyl tert-butyl ether (MTBE), and trichloroethene (TCE). Low-level concentrations of VOCs occurred in a much larger percentage of a subset of the data (the 639 samples analyzed using a low-level analytical method). In these samples, 69 percent of the 639 samples contained 1 or more VOCs, indicating the vulnerability of the carbonate aquifers to low-level VOC contamination. Four VOCs were detected at concentrations exceeding their respective MCLs in five samples, all of which were from drinking-water wells. Vinyl chloride concentrations exceeded the MCL of 2 µg/L in two samples from urban areas in the unconfined Biscayne aquifer. PCE, TCE, and 1,2-dichloropropane each had one sample with a concentration greater than their MCLs of 5 µg/L; these samples were from agricultural and urban areas in the unconfined Mississippian aquifer. Water quality in the 12 carbonate aquifers was highly variable. Most of the samples met drinking-water standards. The occurrence of anthropogenic contaminants was related to contaminant sources but also was affected by degree of aquifer confinement, ground-water age, and redox status. Areas with higher amounts of agricultural or urban land in unconfined aquifers were the most likely to have elevated concentrations of anthropogenic contaminants.

Scientific Investigations Report

Quality of water in the Trinity and Edwards aquifers, south-central Texas, 1996-98

During 1996–98, the U.S. Geological Survey studied surface- and ground-water quality in south-central Texas. The ground-water components included the upper and middle zones (undifferentiated) of the Trinity aquifer in the Hill Country and the unconfined part (recharge zone) and confined part (artesian zone) of the Edwards aquifer in the Balcones fault zone of the San Antonio region. The study was supplemented by information compiled from four ground-water-quality studies done during 1996–98. Trinity aquifer waters are more mineralized and contain larger dissolved solids, sulfate, and chloride concentrations compared to Edwards aquifer waters. Greater variability in water chemistry in the Trinity aquifer likely reflects the more variable lithology of the host rock. Trace elements were widely detected, mostly at small concentrations. Median total nitrogen was larger in the Edwards aquifer than in the Trinity aquifer. Ammonia nitrogen was detected more frequently and at larger concentrations in the Trinity aquifer than in the Edwards aquifer. Although some nitrate nitrogen concentrations in the Edwards aquifer exceeded a U.S. Geological Survey national background threshold concentration, no concentrations exceeded the U.S. Environmental Protection Agency public drinking-water standard. Synthetic organic compounds, such as pesticides and volatile organic compounds, were detected in the Edwards aquifer and less frequently in the Trinity aquifer, mostly at very small concentrations (less than 1 microgram per liter). These compounds were detected most frequently in urban unconfined Edwards aquifer samples. Atrazine and its breakdown product deethylatrazine were the most frequently detected pesticides, and trihalomethanes were the most frequently detected volatile organic compounds. Widespread detections of these compounds, although at small concentrations, indicate that anthropogenic activities affect ground-water quality. Radon gas was detected throughout the Trinity aquifer but not throughout the Edwards aquifer. Fourteen samples from the Trinity aquifer and 10 samples from the Edwards aquifer exceeded a proposed U.S. Environmental Protection Agency public drinking-water standard. Sources of radon in the study area might be granitic sediments underlying the Trinity aquifer and igneous intrusions in and below the Edwards aquifer. The presence of tritium in nearly all Edwards aquifer samples indicates that some component of sampled water is young (less than about 50 years), even for long flow paths in the confined zone. About one-half of the Trinity aquifer samples contained tritium, indicating that only part of the aquifer contains young water. Hydrogen and oxygen isotopes of water provide indicators of recharge sources to the Trinity and Edwards aquifers. Most ground-water samples have a meteorological isotopic signature indicating recharge as direct infiltration of water with little residence time on the land surface. Isotopic data from some samples collected from the unconfined Edwards aquifer indicate the water has undergone evaporation. At the time that ground-water samples were collected (during a drought), nearby streams were the likely sources of recharge to these wells.

Texas

Water quality in south-central Texas, Texas, 1996–98

This report summarizes major findings about water quality in south-central Texas that emerged from an assessment conducted between 1996 and 1998 by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program. Water quality is discussed in terms of local and regional issues and compared to conditions found in all 36 NAWQA study areas, called Study Units, assessed to date. Findings also are explained in the context of selected national benchmarks, such as those for drinking-water quality and the protection of aquatic organisms. The NAWQA Program was not intended to assess the quality of the Nation’s drinking water, such as by monitoring water from household taps. Rather, the assessments focus on the quality of the resource itself, thereby complementing many ongoing Federal, State, and local drinking-water monitoring programs. The comparisons made in this report to drinking-water standards and guidelines are only in the context of the available untreated resource. Finally, this report includes information about the status of aquatic communities and the condition of instream habitats as elements of a complete water-quality assessment. Many topics covered in this report reflect the concerns of officials of State and Federal agencies, water-resource managers, and members of stakeholder groups who provided advice and input during the assessment. Residents who wish to know more about water quality in the areas where they live will find this report informative as well.

Texas

Hydrogeology and ground-water flow in the Edwards-Trinity aquifer-system, west-central, Texas

Two finite-element ground-water flow models were developed for the Edwards&ndash;Trinity aquifer system, west-central Texas, to gain a better understanding of the flow system; one ground-water flow model was developed at a large scale to simulate the regional system and contiguous, hydraulically connected units, and one model was constructed at a smaller more detailed scale to simulate the most active areas of the system. The study area is divided into four geographic subareas: the Trans-Pecos (9,750 square miles), the Edwards Plateau (23,750 square miles), the Hill Country (5,500 square miles), and the Balcones fault zone (3,000 square miles). The major aquifers within the study area are the Edwards&ndash;Trinity aquifer underlying the Trans-Pecos and Edwards Plateau, the Trinity aquifer underlying the Hill Country, and the Edwards aquifer in the Balcones fault zone. Hydraulically connected aquifers include the High Plains aquifer north of the Edwards Plateau, and the Cenozoic Pecos alluvium aquifer adjacent to both the Trans-Pecos and the Edwards Plateau along the Pecos River. Minor contiguous aquifers include the Dockum, Ellenburger&ndash; San Saba, Marble Falls, Hickory, and Lipan, which is adjacent to the Colorado River in Tom Green and Concho Counties, Texas. The ground-water flow equations solved by the finite-element method are based on conservation of mass and energy. The equation for ground-water flow assumes laminar flow through a porous media. In places, the Edwards&ndash;Trinity aquifer system is a fractured karst system in which ground water flows through caverns and other features of secondary porosity development. The regional and subregional models were constructed to synthesize the known hydrologic boundaries and geologic structures into a heterogeneous continuum model of the karst ground-water flow system, rather than simulate the flow through specific fractures and caverns. A heterogeneous continuum or equivalent porous media approach uses an effective transmissivity and anisotropy for each element of the models. The models are calibrated both on water levels (representing potential energy) and estimates of recharge and discharge (for a realistic mass balance). A two-dimensional one-layer large-scale model (55,600 square miles) was developed for the Edwards&ndash;Trinity aquifer system and contiguous, hydraulically connected units, in westcentral Texas. A quasi-three-dimensional, multilayer more detailed scale ground-water flow model (12,300 square miles) was applied to the major aquifers of the Edwards&ndash;Trinity aquifer system in the Hill Country and the Balcones fault zone, and in part of the Edwards Plateau. The ground-water flow system in most of the study area within the Trans-Pecos and Edwards Plateau can be approximated with a one-layer regional model under steady-state conditions. Regionally, the Edwards&ndash;Trinity aquifer system in the Trans-Pecos and Edwards Plateau has been relatively static. Potentiometric maps from predevelopment and postdevelopment (winter 1974&ndash;75) indicate small differences in water levels. In local areas in the Trans-Pecos (in Pecos and Reeves Counties), ground-water withdrawals have exceeded recharge resulting in more than 300 feet of drawdown. Measurable differences between the 1974 and predevelopment potentiometric surfaces have been observed in small areas in the Trans-Pecos and in the northwestern part of the Edwards Plateau. The largest water-level declines in the Trans-Pecos have been observed in Pecos and Reeves Counties, and declines greater than 300 feet have been measured in Reeves County. Comparison of pre- and postdevelopment water budgets for the regional model indicates that the increase in groundwater withdrawals has captured 20 percent of the water that would have naturally discharged to streams, and 30 percent of the natural discharge to springs after ground-water development. Induced recharge from streams to the ground-water system increased by 12 percent in the postdevelopment simulation compared to the predevelopment simulation.

Texas

Hydrogeologic framework of the Edwards-Trinity aquifer system, west-central Texas

The Edwards-Trinity aquifer system underlies about 42,000 square miles of west-central Texas, where mostly gently dipping Lower Cretaceous strata comprise three regional aquifers and two regional confining units. The aquifers are the Edwards Aquifer of the Balcones fault zone, the Trinity Aquifer of the Balcones fault zone and Hill County, and the Edwards-Trinity Aquifer of the Edwards Plateau and Trans-Pecos. The Navarro-Del Rio confining unit confines the downdip part of the Edwards Aquifer, and the Hammett confining unit confines the updip, basal part of the Trinity Aquifer and a small southeastern fringe of the Edwards-Trinity Aquifer. Transmissivity averages less than 10,000 feet squared per day throughout more than 90 percent of the study area as the result of widespread cementation and secondary mineral growth. However, in fractured and leached rocks in the Balcones fault zone, transmissivity averages about 750,000 feet squared per day in the Edwards aquifer, which occupies less than 10 percent of the area.

Texas

Historical saturated thickness of the Edwards-Trinity aquifer system and selected contiguous hydraulically connected units, west-central Texas

The Edwards-Trinity Regional Aquifer-System Analysis (RASA) is one of 25 completed or ongoing studies conducted by the U.S. Geological Survey on regional aquifer systems that individually provide essential quantities of ground water to large parts of the country. Underlying about 42,000 mi 2 of west-central Texas, the Edwards-Trinity aquifer system extends approximately from Atascosa County in the southeast to Culberson County in the northwest and from the Rio Grande in the southwest to the Colorado River in the northeast (sheet 2). The Edwards-Trinity aquifer system spans four geographic subareas: Trans-Pecos, Edwards Plateau, Hill Country, and Balcones fault zone (fig. 1). The names of all aquifers in the study area were adopted for RASA purposes directly from nomenclature mandated by the Texas Water Plan (Texas Water Development Board, 1990). The Cretaceous rocks that compose the Edwards-Trinity aquifer system are primarily limestone and dolomite rock, with lesser quantities of terrigenous sand. Although the lithology varies locally and the rocks are not everywhere permeable in all directions, they combine to form a single regional aquifer system. The aquifer system comprises three aquifers and two confining units (figs. 2 and 3). The water-yielding units are the Edwards aquifer of the Balcones fault zone, the Trinity aquifer of the Balcones fault zone and Hill Country, and the Edwards-Trinity aquifer of the Edwards Plateau and Trans-Pecos. The confining units are the Hammett confining unit, which confines basal parts of the Trinity aquifer in the Hill Country and the Edwards-Trinity aquifer in the eastern part of the Edwards Plateau, and the Navarro-Del Rio confining unit, which confines the Edwards and Trinity aquifers along the southeastern margin of the Balcones fault zone. Parts of the aquifer system not overlain by one of these confining units are unconfined, or nearly so. The purposes of this report are to illustrate the historical distribution of saturated thickness (hereafter referred to as the saturated thickness) in the Edwards-Trinity aquifer system, summarize the reasons for the variation in the saturated thickness, and relate the regional effects of this variation to the distribution of transmissivity. The saturated thickness map (sheet 2) was determined for most of the area by subtracting the altitude of the base of the aquifer system (Barker and Ardis, 1992) from the altitude of the historical potentiometric surface (Bush and others, 1993). Where the Edwards and Trinity aquifers are confined in the Balcones fault zone, the saturated thickness is defined by the thickness of the aquifer system, which was determined by subtracting the altitude of the base of the aquifer system from the altitude of the base of the Navarro-Del Rio confining unit (G.E. Groschen and W.G. Stein, U.S. Geological Survey, written commun, 1990).

Texas

Configuration of the base of the Edwards-Trinity aquifer system and hydrogeology of the underlying pre-Cretaceous rocks, west-central Texas

The Edwards-Trinity aquifer system is underlain by an extensive complex of rocks, ranging from Late Cambrian through Late Triassic in age, that are typically about 10 to perhaps 1,000 times less permeable than those composing the aquifer system. The Cretaceous rocks of the aquifer system are separated from the pre-Cretaceous rocks by an unconformity that spans about 60 million years of erosion during the Jurassic Period. The upper surface of the pre-Cretaceous rock complex forms the base of the Edwards-Trinity aquifer system. The configuration of the base reflects the original topography of the eroded pre-Cretaceous land surface plus the effects of subsequent deformation. The most permeable pre-Cretaceous rocks are in the eastern half of the study area where they compose the Hickory aquifer (in Upper Cambrian rocks), Ellenburger-San Saba aquifer (Upper Cambrian- Lower Ordovician), and Marble Falls aquifer (Lower Pennsylvanian). These aquifers are hydraulically connected to the northeastern fringe of the Edwards-Trinity aquifer system, as their up-turned margins crop out around the flanks of the breached Llano uplift. The Rustler aquifer in rocks of Late Permian age underlies parts of the Trans-Pecos region, where it yields small amounts of greatly mineralized water for industrial and agricultural purposes. The Dockum aquifer in rocks of Late Triassic age directly underlies the Edwards-Trinity aquifer system in western parts of the study area, and locally increases the saturated thickness of the ground-water-flow system by an average of about 200 feet. Despite these notable exceptions, the collective effect of the pre-Cretaceous rocks is that 01 a barrier to ground-water flow, which limits the exchange of water across the base of the Edwards-Trinity aquifer system.

Texas

Hydrology of the Texas Gulf Coast aquifer systems

A complex, multilayered ground-water flow system exists in the Coastal Plain sediments of Texas. The Tertiary and Quaternary clastic deposits have an areal extent of 114,000 square miles onshore and in the Gulf of Mexico. Two distinct aquifer systems are recognized within the sediments, which range in thickness from a few feet to more than 12,000 feet The older system--the Texas coastal uplands aquifer system-consists of four aquifers and two confining units in the Claiborne and Wilcox Groups. It is underlain by the practically impermeable Midway confining unit or by the top of the geopressured zone. It is overlain by the nearly impermeable Vicksburg-Jackson confining unit, which separates it from the younger coastal lowlands aquifer system. The coastal lowlands aquifer system consists of five permeable zones and two confining units that range in age from Oligocene to Holocene. The hydrogeologic units of both systems are exposed in bands that parallel the coastline. The units dip and thicken toward the Gulf. Quality of water in the aquifer systems is highly variable, with dissolved solids ranging from less than 500 to 150,000 milligrams per liter. Substantial withdrawal from the aquifer systems began in the early 1900's and increased nearly continuously into the 1970's. The increase in withdrawal was relatively rapid from about 1940 to 1970. Adverse hydrologic effects, such as saltwater encroachment in coastal areas, land-surface subsidence in the Houston-Galveston area, and long-term dewatering in the Whiter Garden area, were among some of the factors that caused pumping increases to slow or to cease in the 1970's and 1980's. Ground-water withdrawals in the study area in 1980 were about 1.7 billion gallons per day. Nearly all of the withdrawal was from four units: Permeable zones A, B, and C of Miocene age and younger, and the lower Claiborae-upper Wilcox aquifer. Ground-water levels have declined hundreds of feet in the intensively pumped areas of Houston-Galveston, Kingsville, Winter Garden, and Lufkin-Nacogdoches. Water-level declines have caused inelastic compaction of clays which, in turn, has resulted in land-surface subsidence of more than one foot in an area of about 2,000 square miles. Maximum subsidence of nearly 10 feet occurs in the Pasadena area east of Houston. A three-dimensional, variable-density digital model was developed to simulate predevelopment and transient flow in the aquifer systems. The modeled area is larger than the study area, and includes adjacent parts of Louisiana and Mexico. The transient model calibration period was from 1910 (predevelopment) to 1982. Model-generated head distributions, water-level hydrographs, and land-surface subsidence were matched to measured data in selected, intensively pumped areas. For the study area, mean horizontal hydraulic conductivity in the calibrated model ranges from 10 feet per day for the middle Wilcox aquifer to 25 feet per day for permeable zone A. Mean transmissivity ranges from about 4,600 feet squared per day for the middle Claiborne aquifer to about 10,400 feet squared per day for permeable zone D. Mean vertical hydraulic conductivity ranges from 1.1x10 -5 feet per day for the Vicksburg-Jackson confining unit, to 3.8x10 -3 feet per day for permeable zone A. Mean values of calibrated storage coefficient range from 52x10 -4 for the middle Claiborne aquifer to 1.7x10 -3 for the middle Wilcox aquifer and permeable zone C. Calibrated inelastic specific storage values for clay beds in permeable zones A, B, and C in the Houston-Galveston area are 8.5x10 -5 , 8.0x10 -5 , and 8.0x10 -6 feet -1 , respectively. These values are 85, 80, and 8 times greater than the estimated elastic specific storage value for the clays in permeable zones A, B, and C, respectively. Recharge rates were mapped for predevelopment conditions as determined from a steady-state model calibration. A maximum rate of 3 inches per year was simulated in small areas, and the average rate for the study area was 034 inch per year. Total simulated recharge was 85 million cubic feet per day in the outcrop area. Recharge was equal to discharge in outcrop areas (79 million cubic feet per day) plus net lateral flow out of the study area (6 million cubic feet per day). Rates of inflow and outflow to the ground-water system have nearly tripled from predevelopment to 1982 (85 to 276 million cubic feet per day) based on model simulation. Withdrawal of 231 million cubic feet per day was supplied principally by an increase in outcrop recharge and, to a lesser extent, from a decrease in natural discharge and release of water from storage in aquifers and compacting clay beds. The average simulated 1982 recharge rate for the study area was 0.52 inch per year, with a maximum simulated rate of 6 inches per year in Jackson and Wharton Counties. Because withdrawal has caused problems such as saltwater intrusion, land-surface subsidence, and aquifer dewatering, the Texas Department of Water Resources has projected that ground-water use will decline substantially in most of the study area by the year 2030. Some areas remain favorable for development of additional ground-water supplies. Pumping from older units that are farther inland and in areas where potential recharge is greater will minimize adverse hydrologic effects.

Texas

Recharge zone of the Edwards aquifer hydrologically associated with Barton springs in the Austin area, Texas

The Edwards aquifer extends in a narrow belt from Bell County in the northeast to Kinney County in the southwest (index map) and provides water for at least nine counties in south-central Texas. Hydrologic boundaries divide the Edwards aquifer in the Austin area for which Barton Springs is the major discharge point. This part of the Edwards aquifer provides the municipal, industrial, domestic, and agricultural water supplies for about 30,000 people in the Austin area (southern Travis and northern Hays counties). Discharge from Barton Springs sustains streamflow at the mouth of Barton Creek and flows into Town Lake. Much of the land use within the outcrop area of the Edwards aquifer near Austin is rapidly changing from natural woodland and grassland to commercial and residential developments. Because urban development can result in a substantial degradation of the quality of water that recharges the aquifer, the extent of the recharge zone of the Edwards aquifer was delineated to provide information to the City of Austin for their use in formulating a plan for protecting and managing groundwater quality. The purpose of this report is to define and delineate the areal extent of the recharge zone of the Edwards aquifer in southern Travis and northern Hays Counties. The areal boundary of the recharge zone was determined by: (1) geologic mapping of the aquifer area; (2) interpretation of aerial photographs; (3) field verification of existing geologic maps; and (4) streamflow-loss studies.

Water-Resources Investigations Report

Delineation of the outcrop of the Edwards Aquifer hydrologically associated with Barton Springs in the Austin area, Texas

This report, prepared in cooperation with the City of Austin, delineates the outcrop of the Edwards aquifer that is hydrologically associated with Barton Springs. The Edwards is a regional aquifer system in central Texas that extends in a narrow belt from Kinney County to Bell County (index map) and lies within an area locally known as the Balcones fault zone. Hydrologic boundaries separate the Edwards auifer into several parts. Barton Springs is the major discharge point of the part of the Edwards aquifer in the Austin area (southern Travis and northern Hays Counties).

Open-File Report