Geology Reports⌕ Search

Geology topics

Alex R. Fiore

Publications and source records attributed to Alex R. Fiore.

17 recordsLinked to original sources

Potentiometric surface maps and groundwater-level hydrographs for confined aquifers of the New Jersey Coastal Plain, 2018

The U.S. Geological Survey, in cooperation with the New Jersey Department of Environmental Protection (NJDEP), prepared potentiometric surface maps for 10 confined aquifers of the New Jersey Coastal Plain physiographic province based on water-level measurements collected during late 2018 and early 2019 from 951 wells in New Jersey and parts of Pennsylvania and Delaware. Maps were prepared for the confined Cohansey aquifer, Rio Grande water-bearing zone, Atlantic City 800-foot sand, Piney Point aquifer, Vincentown aquifer, Wenonah-Mount Laurel aquifer, Englishtown aquifer system, and the upper, middle, and lower aquifers of the Potomac-Raritan-Magothy aquifer system. Potentiometric surface maps indicate regional cones of depression in the following aquifers and the counties in which they are centered: Atlantic City 800-foot sand in Atlantic County, the Piney Point aquifer in Cumberland County, the Wenonah-Mount Laurel aquifer and Englishtown aquifer system in Monmouth and Ocean Counties, the Wenonah-Mount Laurel aquifer in Camden and Gloucester County, the upper aquifer of the Potomac-Raritan-Magothy aquifer system in Ocean County, and the upper, middle, and lower aquifers of the Potomac-Raritan-Magothy aquifer system in Camden County. Cones of depression with smaller areal extents were in the confined Cohansey aquifer, the Rio Grande water-bearing zone, the Atlantic City 800-foot sand centered in Cape May County, the Piney Point aquifer centered in Ocean County, the Wenonah-Mount Laurel aquifer in Salem and Burlington Counties, the Englishtown aquifer system in Camden County, the upper aquifer of the Potomac-Raritan-Magothy aquifer system in Monmouth County, and the middle aquifer of the Potomac-Raritan-Magothy aquifer system in Monmouth, Ocean, and Salem Counties. No cone of depression was interpreted in the Vincentown aquifer. Long-term hydrographs are presented for 75 wells spanning each of the 10 confined aquifers, and contain a mix of discrete water-level measurements and daily mean water levels based on continuously recorded 15-minute data. Changes of water levels during 2014–19, as indicated by the hydrographs, were compared with those of previous periods to assess any departures from historical data. During 2014–19, water levels were stable and fluctuated within similar ranges as previous periods in the following aquifers and locations: all wells in the confined Cohansey aquifer, the Rio Grande water-bearing zone, the Vincentown aquifer, the Englishtown aquifer system, the Piney Point aquifer wells in Burlington and Ocean Counties, six of eight wells in the Wenonah-Mount Laurel aquifer, all wells in the upper and lower aquifers of the Potomac-Raritan-Magothy aquifer system outside NJDEP Critical Areas, and all wells in the middle aquifer of the Potomac-Raritan-Magothy aquifer system except those within NJDEP Critical Area II. Increasing water levels in 2014–19, ongoing since historical periods, were indicated in the following aquifers and locations: Atlantic County wells in the Piney Point aquifer, all wells in the upper and lower aquifers of the Potomac-Raritan-Magothy aquifer system outside NJDEP Critical Areas, and all wells in the middle aquifer of the Potomac-Raritan-Magothy aquifer system within NJDEP Critical Area II. Water levels in the Atlantic City 800-foot sand also increased during 2014–19 in wells in Atlantic County and northern Cape May County closer to the center of the cone of depression in that aquifer, which is a response unique to this period and absent from previous periods. During 2013–19, continued decreasing water levels, ongoing since previous periods, were indicated by hydrographs of Atlantic City 800-foot sand wells in southern Cape May County, Piney Point aquifer wells in Cumberland County where the regional cone of depression is located, and two wells in the Wenonah-Mount Laurel aquifer—070478, which in 2014–19 departed from previous periods, and 330020, which continued a gradual decrease throughout its period of record.

New Jersey↗

Results of 2018–19 water-quality and hydraulic characterization of aquifer intervals using packer tests and preliminary geophysical-log correlations for selected boreholes at and near the former Naval Air Warfare Center Warminster, Bucks County, Pennsylvania

The U.S. Geological Survey (USGS) collected data on the vertical distribution of hydraulic head, specific capacity, and water quality using aquifer-interval-isolation tests and other vertical profiling methods in 15 boreholes completed in fractured sedimentary bedrock in Northampton, Warminster, and Warwick Townships, Bucks County, Pennsylvania during 2018–19. This work was done, in cooperation with the U.S. Navy, to support detailed investigations at and near the former Naval Air Warfare Center (NAWC) Warminster, where groundwater contamination with per- and polyfluoroalkyl substances (PFAS) had become a concern since 2014. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), have been measured in groundwater samples from supply and monitoring wells at or near NAWC Warminster in concentrations above U.S. Environmental Protection Agency health advisory levels for drinking water. The area is underlain by the Triassic Stockton Formation, which predominantly consists of sandstone interbedded with shale and siltstone beds and forms a layered fractured-rock aquifer used for private, industrial, and public drinking water supply. The vertical distribution of aquifer properties and water quality was assessed through hydraulic tests and sampling of aquifer intervals using a straddle-packer system (13 boreholes) or depth-discrete point sampling under known borehole-flow conditions (2 boreholes). Geophysical and video logs collected by USGS during 2017–19 were used to identify potential water-bearing fractures in 15 boreholes, which ranged in depth from 210 to 604 feet (ft) and included 6 boreholes drilled in 2018 and 9 existing wells on or near the former NAWC Warminster. Measured borehole flow was predominantly downward in most of the deepest boreholes (greater than 400 ft), which were commonly located at the highest land-surface elevations, with inflow from fractures at relatively shallow depths and outflow through fractures near or below depths of 500 ft below land surface. Hydraulic head differences measured during packer tests were up to about 60 ft between shallow and deep intervals. Borehole flow was predominantly upward in most boreholes less than 400 ft in depth and farther from, and at lower land-surface elevations than, the former NAWC Warminster. Total borehole specific capacity ranged from about 0.07 to 41 gallons per minute per foot [(gal/min)/ft]. Specific-capacity values for individual intervals ranged from 0.02 to 40.0 (gal/min)/ft, with a median of 1.14 (gal/min)/ft and a large range in values at most depths. Differences in water quality of samples as indicated by field properties (pH, dissolved oxygen, and specific conductance) and concentrations of dissolved major ions, PFOA, and PFOS were apparent among isolated intervals in the boreholes. Summed concentrations of PFOA and PFOS ranged from about 11 to 10,780 nanograms per liter (ng/L) and were greater than the 2016 U.S. Environmental Protection Agency health advisory of 70 ng/L for summed PFOA and PFOS concentrations in 62 of 104 intervals and discrete depths tested. The mass ratio of PFOS to PFOA was generally higher than 1.0 in samples with summed PFOA and PFOS concentrations greater than 70 ng/L, with ratio values as high as 8.7. In many boreholes, summed concentrations of PFOA and PFOS were positively related to chloride concentrations, which were elevated above natural-background values [less than 10 milligrams per liter] in most samples and as high as 717 milligrams per liter. Sources of the elevated chloride other than, or in addition to, common rock salt (sodium chloride) were indicated by chloride to sodium molar ratios greater than 1.0. Water-quality data indicated that sampled water from some intervals with lower hydraulic heads may be affected by water from intervals with higher hydraulic heads because of vertical flow in open boreholes; samples from these intervals with lower hydraulic heads may not be fully representative due to some component of cross contamination and should be interpreted with caution. Through a preliminary correlation of natural gamma and resistivity logs of boreholes drilled at and near the former NAWC Warminster, 11 lithologic units were identified and interpreted to strike northeast and dip to the northwest. Hydraulic heads were generally highest in isolated intervals that intercepted beds which, when projected up dip, crop out at the highest land-surface elevation on the former NAWC Warminster, indicating that the dipping-bed structure and topography are factors affecting the distribution of hydraulic head in the aquifer. The hydrogeologic framework in conjunction with the vertical distribution of hydraulic heads and water quality may assist in evaluating the locations of various PFAS sources and potential migration pathways of PFAS in groundwater at and near NAWC Warminster.

Pennsylvania↗

Geology, hydrology, and groundwater contamination in the vicinity of Central Chemical facility, Hagerstown, Maryland

The soil and groundwater at the Central Chemical facility, Hagerstown, Maryland, are contaminated due to the blending and production of pesticides and fertilizers during much of the 20th century. Remedial investigations focus on two operable units (OU) consisting of the surface soils and waste disposal lagoon (OU-1) and the groundwater (OU-2). The contaminants of concern (COC) for groundwater include 41 compounds categorized within the subgroups of volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs), pesticides, and metals. The purpose of this report is to provide a conceptual site model of the hydrogeology and groundwater contaminant transport at and near the Central Chemical facility. The conceptual model was developed through review, synthesis, and interpretation of the results of hydrogeologic, soil, and other environmental investigations conducted at and in the vicinity of the facility in recent decades and is intended to support plans for environmental remediation of the groundwater in OU-2. The extent and nature of the groundwater contaminant plume associated with the bedrock was characterized for OU-2 of the site. Lithologic and structural comparisons between shallow soil, weathered rock, and epikarst and deeper competent but bedded, dipping, fractured, and karstic limestones illustrate two connected flow systems—a surficial flow system consisting of the unconsolidated overburden and epikarst and a structurally dominant bedrock flow system below the epikarst. Uncertainties exist regarding the nature and transport of contaminants within the epikarst system particularly within voids and perched epikarst water tables. Karst dissolution features are observed within the site including sinkholes and dissolution voids within wells at the site. Of interest, one well in the northern part of the study area (MW-J-71) appears to have a dissolution void connected to an offsite well (OW-2-115) farther to the north. This connection is supported by groundwater level data and elevated concentrations of total suspended solids (TSS) and chlorobenzene in both wells. The high level of TSS supports the possibility of offsite transport of particle-bound contaminants within the conduit system. Episodically elevated concentrations of COC from different groups also were observed within select wells in the epikarst near the waste disposal lagoon (particularly MW-A-51). The variability observed between different COC within the same well may be the result of additional contaminated source materials unrelated to the disposal lagoon. Storage and episodic transport of contaminated material within the epikarst system has the potential to hinder remediation efforts if not considered in the remedial action.

Maryland↗

Distribution of chlorinated volatile organic compounds and per- and polyfluoroalkyl substances in groundwater and surface water at the former Naval Air Warfare Center, West Trenton, New Jersey, 2018

Groundwater wells and surface-water storm sewers contaminated with volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFASs) at the former Naval Air Warfare Center (NAWC) site in West Trenton, New Jersey were sampled in 2018 as part of the Navy’s long-term monitoring program. Trichloroethene (TCE), cis-1,2-dichloroethene (cisDCE), and vinyl chloride concentrations were plotted in map view and selected cross sections to elucidate the vertical and horizontal extent and distribution of contamination, along with a tabular comparison between 2018 and previous analytical results. The 2018 data showed that the areas of VOC contamination (>1 microgram per liter) decreased slightly on the north and east sides of the NAWC site from previous sampling dates; these decreases are attributed to the influence of the pump-and-treat system, natural attenuation processes, and various engineered bioaugmentation experiments that have occurred onsite. Off-site groundwater samples indicate the VOC contaminated groundwater is likely hydraulically constrained by the pump-and-treat system and appears to not be moving offsite to the south and west of NAWC. Only one offsite well, 50BR, located along the eastern margin of the site, was found to have detectable TCE and cisDCE concentrations, indicating that VOC contamination continues to migrate a short distance offsite to the east. Detectable VOC contamination was found in wells as deep as 200 and 221 feet on both the east and west sides of the NAWC site. Comparisons of present-day data to data from past sampling efforts indicate that TCE concentrations in most wells have decreased slowly over time. Results from surface-water samples indicate that VOCs enter surface water predominantly through the West Ditch drainage system. Concentrations and fluxes of VOCs are higher when groundwater levels are higher, indicating contaminated groundwater discharges into the surface water system. Higher VOC concentrations at the Interceptor site relative to other sites in the West Ditch indicate the contamination in the West Ditch system is likely caused by contaminated groundwater discharging to the West Ditch storm sewer near manhole MH-140 when water table levels are high. The pump-and-treat extraction wells at the former NAWC site were sampled for per- and polyfluoroalkyl substances (PFAS) in 2018. The suite of reported PFAS include perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid, and perfluorobutane sulfonate. Concentrations were plotted in map view to determine the areal extent of the PFAS contamination at the site. Extraction well 48BR sampled on the eastern half of the site was found to have PFOS and PFOA concentrations greater than the New Jersey Department of Environmental Protection Drinking Water maximum contaminant levels (MCLs), which is consistent with the distribution of highest PFAS concentrations in surface water in the OF-4 storm sewer system that drains that area, as well as previously collected PFAS concentrations in monitoring wells. On the western half of the site, the extraction well 08BR sample exceeded MCLs for PFOA and PFOS and the extraction well 22BR sample exceeded the MCL for PFOA, but samples from all other extraction wells were below the MCLs or other criteria for all PFAS analyzed. Concentrations of PFOA exceeded concentrations of PFOS on the west side of NAWC in both groundwater and surface water, which contrasts with the conditions on the east side of NAWC where PFOS concentrations exceeded PFOA concentrations. However, this observation was based on a limited number of samples on the west side of NAWC from 2018 and previous years, so more PFAS sampling is needed on the west side to assess this further.

New Jersey↗

Simulation of regional groundwater flow and advective transport of per- and polyfluoroalkyl substances, Joint Base McGuire-Dix-Lakehurst and vicinity, New Jersey, 2018

A three-dimensional numerical model of groundwater flow was developed and calibrated for the unconsolidated New Jersey Coastal Plain aquifers underlying Joint Base McGuire-Dix-Lakehurst (JBMDL) and vicinity, New Jersey, to evaluate groundwater flow pathways of per- and polyfluoroalkyl substances (PFAS) contamination associated with use of aqueous film forming foam (AFFF) at the base. The regional subsurface flow model spans an area of approximately 518 square miles around JBMDL and is based on a previously developed hydrogeologic framework of the area. Steady-state flow in the unconsolidated aquifers was simulated using the MODFLOW 6 groundwater flow model, which is able to account for hydrostratigraphic pinchouts and discontinuities in the Coastal Plain aquifers underlying JBMDL. To account for local patterns of fluid flow driving advective subsurface migration of PFAS, the grid was refined using quadtree meshes spanning 21 areas where historical AFFF use was identified, five off-site reconnaissance areas identified by AFCEC as areas in which the occurrence of PFAS is most likely to pose a potential danger to local drinking water supplies, and along streams that behave as drains in the base-flow-dominated Coastal Plain. Following grid refinement, four physical processes known to govern subsurface flow were introduced to the model. These included effective precipitation recharge, discharge to streams and stream-connected wetlands, regional inflows and outflows along the model bottom, and withdrawals from wells, each of which were incorporated into the model as either external or internal boundary conditions. To account for effective precipitation recharge, a specified-flow boundary was assigned along the top of the model. Similarly, regional flows predicted using the modified U.S Geological Survey’s New Jersey Coastal Plain Regional Aquifer System Analysis model were treated as specified-flow boundary conditions along the bottom of the model. Base-flow losses were treated as drains along streams delineated using a 10-foot LiDAR dataset. Drains were also assigned to cells falling within stream-connected National Hydrologic Database wetlands. Finally, well-pumpage data mined from the New Jersey Water Transfer database were added to the model to account for extraction of groundwater through pumping from industrial-supply and drinking-water-supply wells. Along model edges established at groundwater divides, where the net flux of water across the boundary is equal to zero, natural no-flow boundary conditions were imposed. The refined flow model was calibrated using the parameter-estimation (PEST) program, which adjusts model parameters by performing a gradient search over the sum-of-squared-error objective function until the parameter set that produces simulated water levels and base flows most closely matches 544 water levels and 20 estimated base flows and closely adheres to initial parameter estimates. Based on the analysis of calibration residuals, the model did not appear to be affected by significant model structural error. The MODPATH particle-tracking algorithm was used to estimate advective transport paths of PFAS in the vicinity of JBMDL. Forward tracking was used to determine paths of PFAS away from AFFF source areas to streams, wetlands, pumping wells, and geographic areas that PFAS may contaminate. Additionally, reverse tracking was used to determine particle pathlines away from off-site PFAS reconnaissance areas, or areas within which all sources of PFAS might be advectively transported into subsurface drinking-water supplies, to locations at land surface that may indicate a source of PFAS. The coupled and calibrated groundwater flow and particle-tracking transport model provide valuable tools for predicting the relative extent of PFAS contamination from onsite legacy source areas. The calibrated model also provides measures of water-level and base-flow observation influence that can help guide future data-collection efforts related to groundwater and surface water sampling for PFAS.

New Jersey↗

Hydrogeology and gain/loss assessment of two lakes contaminated with per- and polyfluoroalkyl substances, vicinity of Joint Base McGuire-Dix-Lakehurst, New Jersey, 2020–21

Per- and polyfluoroalkyl substances (PFAS) have been identified in two lakes near Joint Base McGuire-Dix-Lakehurst (JBMDL) in New Jersey—Little Pine Lake in Pemberton Township and Pine Lake in Manchester Township. The streams that enter these lakes begin in or near JBMDL where sources of PFAS contamination are located. The U.S. Geological Survey, in cooperation with the U.S. Air Force Civil Engineer Center, performed a study of the hydrogeology and the gaining or losing conditions associated with these lakes. Hydrogeologic characteristics in the vicinity of both lakes were assessed using qualitative vertical hydraulic profiling of the subsurface. Groundwater was pumped from test intervals at various depths below land surface, then groundwater levels were measured until they recovered to static conditions. Low permeability aquifer intervals were identified within the aquifer underlying both lakes, consistent with silty and (or) clayey subunits of the Kirkwood-Cohansey aquifer system indicated on geophysical and lithologic logs. Gaining or losing conditions between groundwater and lake surface water were assessed with continuous monitoring of water levels and temperature in the lakes and in three piezometers per lake screened at different depths in the underlying aquifer from August 2020 through May 2021. At Little Pine Lake, surface water levels were consistently lower than groundwater levels, which is indicative of a gaining condition with groundwater flowing into the lake. Gaining conditions also support the lack of diurnal temperature fluctuations observed in groundwater, but poor response of surface-water temperature prevents complete analysis. The potential for losing conditions at other locations around Little Pine Lake necessitates further assessment in regard to possible PFAS contamination of groundwater in the underlying aquifer. Temperature results were inconclusive at Pine Lake, but surface water levels were consistently higher than groundwater levels throughout the monitoring period, which indicates a losing condition with lake water flowing into the underlying aquifer. Because of the downward vertical hydraulic gradient identified at Pine Lake, there is a strong possibility that PFAS in the lake water has also contaminated groundwater in its vicinity.

New Jersey↗

Hydrogeologic framework, water levels, and selected contaminant concentrations at Valmont TCE Superfund Site, Luzerne County, Pennsylvania, 2020

The Valmont TCE Superfund Site, Luzerne County, Pennsylvania is underlain by fractured and folded sandstones and shales of the Pottsville and Mauch Chunk Formations, which form a fractured-rock aquifer recharged locally by precipitation. Industrial activities at the former Chromatex Plant resulted in trichloroethene (TCE) contamination of groundwater at and near the facility, which was identified in 1987 and led to listing as a Superfund site by the U.S. Environmental Protection Agency (EPA) in 1989. To address the problem of TCE concentrations in nearby residential wells that exceed the maximum contaminant level (MCL) of 5 micrograms per liter (μg/L), alternate water supplies were provided. A 2015 review of initial characterization and subsequent remediation by the EPA identified the need for an updated understanding of the complex hydrogeology and the conceptual site model. Additional contaminants present in groundwater at the site include some other volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFAS), predominantly consisting of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) present in concentrations that exceeded the EPA Health Advisory (HA) level of 5 nanograms per liter (ng/L) for combined PFOA and PFOS. In response to a request from the EPA in 2019, the U.S. Geological Survey (USGS) prepared cross sections and maps to provide more information about the hydrogeologic framework at and near the site and assist in improving the conceptual site model using water level and contaminant data collected by the EPA in 2020. The cross sections present lithologic correlations from available geophysical logs collected in wells from 2002 to 2014; they show alternating intervals of relatively elevated and reduced natural gamma activity that correspond to changes in lithology, with water-bearing zones and well screens commonly located at lithologic contacts, sometimes near thin coal seams. Water-bearing zones commonly are associated with fractures at or near lithologic contacts but also may be associated with fractures at or near apparent faulting. Recent (March 2020) water-level data shown on cross sections and maps indicate large downward vertical gradients and apparent radial gradients laterally to the northeast, northwest, and southwest that generally following topography. Recent (February to March 2020) data for TCE groundwater concentration shown on cross sections and maps indicate the highest TCE concentrations (greater than 3,000 μg/L and as much as 75,000 μg/L) and combined PFOA and PFOS concentrations (greater than 1,000 ng/L and up to at least 2,350 ng/L) are from shallow (less than 60 feet [ft] below land surface [bls]) and intermediate depth (60 to 100 ft bls) wells near the center of the former Chromatex Plant. TCE and PFAS (as combined PFOA and PFOS) contamination is present at greater depths, as much as 304 ft bls, as evidenced by samples collected from one well (a reconstructed former production well) near the plant, that contained concentrations of about 240 μg/L and 508 ng/L, respectively. The 2020 data also indicate that TCE and PFAS concentrations which exceed drinking-water MCL or HA levels are present in groundwater depths of less than 200 ft in an area that extends predominantly in a northeast direction from the former Chromatex Plant, and is apparently influenced by hydraulic gradients, lithology, and geologic structure.

Pennsylvania↗

Simulation of water-table response to sea-level rise and change in recharge, Sandy Hook unit, Gateway National Recreation Area, New Jersey

The Sandy Hook Unit, Gateway National Recreation Area (hereafter Sandy Hook) in New Jersey is a 10-kilometer-long spit visited by thousands of people each year who take advantage of the historical and natural resources and recreational opportunities. The historical and natural resources are threatened by global climate change, including sea-level rise (SLR), changes in precipitation and groundwater recharge, and changes in the frequency and severity of coastal storms. Fresh groundwater resources are important to the ecosystems of Sandy Hook. The Bayside Holly Forest, one of only two known old-growth American holly ( Ilex opaca ) maritime forests, is particularly vulnerable to global climate change because of the proximity of the water table to land surface in low-lying areas and the potential for saltwater intrusion and inundation. The shallow groundwater-flow system on Sandy Hook is dominated by recharge from precipitation, fresh groundwater discharge to evapotranspiration (ET), discharge to surface seeps, and submarine groundwater discharge (groundwater discharging directly to the ocean). A three-dimensional groundwater-flow model that simulates the shallow groundwater-flow system and interaction with surrounding saltwater boundaries was constructed to simulate multi-density groundwater flow, treating the freshwater/saltwater transition zone as a sharp interface that represents the half-seawater surface. Groundwater-flow simulations completed for this study include a Baseline scenario, three SLR scenarios (0.2, 0.4, and 0.6 meter [m]), two Recharge scenarios—a 10-percent Increased Recharge scenario and a 10-percent Decreased Recharge scenario—and a scenario with 0.6 m of SLR and 10-percent increase in recharge. The Recharge scenarios indicate the system is not sensitive to a 10-percent increase or decrease in recharge from the Baseline scenario. In the SLR scenarios, SLR causes the water table to rise, resulting in increased fresh groundwater discharge to ET and seeps, and reduced submarine discharge compared to the Baseline scenario. The increased discharge to ET and seeps causes the magnitude of water-table rise to be less than that of SLR, which in turn causes the thickness of the freshwater lens to thin, reducing the depth to the half-seawater surface. Water-table rise associated with SLR diminishes the thickness of the unsaturated zone; comparing the Baseline and the 0.6-m SLR scenarios, the area where the simulated water table is above land surface increases by 50.6 hectares, from about 0.9 to 7.4 percent of the land area of Sandy Hook. Areas where the simulated water table is above land surface are likely to be emergent wetlands and contain freshwater if they are tens of meters or more from the shoreline. The steady-state simulations indicate that the percentage of land where the half-seawater surface is less than 9 m below the water table increases from about 2.5 percent (20 hectares) to about 9 percent (74 hectares) with 0.6 m of SLR. In low-lying areas close to the Sandy Hook Bay shoreline, the half-seawater surface is simulated to be as much as 20 m closer to the water table with SLR of 0.6 m. Transient salinization, if any, of shallow groundwater from increased frequency or severity of storm-driven inundation is not included in the analysis. Natural resources on Sandy Hook, particularly the Bayside Holly Forest, may be adversely affected by the rising water table associated with SLR. Freshwater emergent wetlands may increase in area at the expense of other ecosystem assemblages occurring in or on the edges of low-lying enclosed depressions. Cultural resources close to the water table, such as existing basements of structures, may be adversely affected.

New Jersey↗

Distribution of chlorinated volatile organic compounds and per- and polyfluoroalkyl substances in monitoring wells at the former Naval Air Warfare Center, West Trenton, New Jersey, 2014–17

A study was conducted by the U.S. Geological Survey in cooperation with the U.S. Navy (the Navy) to determine the status of volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFASs) in groundwater at the former Naval Air Warfare Center (NAWC) in West Trenton, New Jersey. Wells contaminated with VOCs were sampled in 2014, 2015, 2016, and 2017 as part of the Navy’s long-term monitoring program. The results for trichloroethene (TCE), cis-1,2-dichloroethene (cisDCE), and vinyl chloride (VC) were plotted in map view to determine whether the areal extent of the contamination had changed over the 4-year period. TCE, cisDCE, and VC concentrations were plotted along nine lines of section across the former NAWC site to determine whether the vertical distribution of VOCs had changed during 2014–17. TCE, cisDCE, and VC concentrations over time were plotted on graphs for each well to determine long-term trends and changes in VOC concentrations. Data from 1990 to 2017 were used, if available, to make these graphs. Results show that the areas of VOC concentrations greater than or equal to 1 microgram per liter decreased slightly on the northwestern side and the northeastern side of the NAWC site from 2014 to 2017 under the influence of a pump-and-treat system, natural attenuation processes, and engineered bioaugmentation experiments ongoing at the site. The pump-and-treat system continued to hydraulically contain the VOC contamination and kept it from moving offsite to the south and west of NAWC. One well northeast of the NAWC site, 50BR, was found to have detectable TCE and cisDCE concentrations. These detections indicated that VOC contamination had migrated offsite and that the pump-and-treat system was not containing the VOC contamination on the eastern side of the facility. Detectable VOC concentrations were present in wells as deep as 200 and 221 feet on the eastern and western sides of the NAWC site. TCE concentrations in most wells were found to be stable or to have slowly decreased since the facility closed in 1999. Only 7 wells, including 3 pump-and-treat extraction wells, showed substantial increases in TCE concentration from 2014 to 2017. Continuing sources of TCE to the system are desorption of TCE from organic materials in the aquifer, back diffusion of TCE from the contaminated bedrock matrix, and dissolution of remaining dense nonaqueous phase TCE in the aquifer. Wells at the former NAWC site were sampled for PFASs in 2015, 2016, and 2017. Perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), and perfluorononanoic acid (PFNA) results were plotted in map and cross-section views to determine the areal and vertical extent of the PFAS contamination at the site. PFOS, PFOA, and PFNA concentrations greater than their established maximum contaminant levels were detected in 25, 24, and 21 of the 26 wells sampled, respectively, on the eastern side of NAWC in 2017. Vertically, the highest PFAS concentrations were present in shallow wells along the fence near the firehouse and along the railroad tracks where the aqueous film-forming foam discharge reportedly occurred back in 1990. PFAS concentrations were detected in one well (54BR) as deep as 200 feet on the eastern side of the NAWC site. PFASs were present in wells east of the railroad tracks, indicating that PFAS-contaminated groundwater had moved offsite. In a limited test of five wells, samples collected with regenerated cellulose dialysis membrane (RCDM) passive samplers contained PFAS concentrations equal to those in samples from low-flow purging.

New Jersey↗

Capturing the transient hydrological response in sandy soils during a rare cloudburst associated with shallow slope failures; A case study in the Atlantic Highlands, New Jersey, USA

A cloudburst on 7 August 2018 in the coastal bluffs of the Atlantic Highlands, New Jersey, induced flooding, erosion and multiple shallow slope failures that adversely affected the surrounding hillside residential area. Historically, short-duration deluges are rare in the New York Bay region, with only eight cloudbursts of greater magnitude documented since 1948. The coastal bluffs consist of a variably thick, sandy surficial material overlying flat-lying, mostly non-indurated Cretaceous and Tertiary sediments, including some low-permeability glauconitic units. The bluffs have been affected by both historical deep-seated and shallow landslide movement, the latter typically related to heavy, relatively long-duration rainfall associated with tropical cyclones and nor'easters. The shallow hydrological response during the rare cloudburst was captured at two hydrological monitoring sites and yielded insights into rapidly changing moisture conditions resulting in slope failure. Additional information is provided on historical cloudbursts that have affected the region, antecedent moisture conditions, and documented landslide types and processes.

New Jersey↗

Groundwater levels and generalized potentiometric surfaces, former Naval Air Warfare Center, West Trenton, New Jersey, 2018

Groundwater-level conditions, generalized groundwater potentiometric surfaces, and generalized flow directions at the decommissioned Naval Air Warfare Center in West Trenton, New Jersey, were evaluated for calendar year 2018. Groundwater levels measured continuously in five on-site wells and one nearby off-site well were plotted as hydrographs for January 1, 2018, through December 31, 2018. Groundwater levels measured in 110 wells on June 18, 2018, were contoured as generalized potentiometric surfaces on maps and sections. Generalized groundwater-flow directions inferred from the June 2018 data are shown in the maps and sections. Groundwater levels in six monitoring wells fluctuated in response to seasonal changes, precipitation, and pumping from “pump-and-treat” (P&T) wells. Record high precipitation totals in November, combined with a shutdown of three P&T wells in November, resulted in annual high water levels in late November for five of the six wells monitored. Annual high groundwater levels that occur during the fall are uncharacteristic of the typical timing of annual high water levels, which usually occur in the spring following low evapotranspiration during the winter months, compared to annual low water levels, which usually occur in fall because of high evapotranspiration during the summer months. The annual high water levels occurred following a 3-day precipitation event totaling 3.50 inches from November 24-26, which also caused the largest 1-day water-level increase for five of the six wells in 2018. The groundwater-level contour maps and sections include generalized flow directions. Given the heterogeneity of the site’s fractured rock aquifers, contours and associated groundwater-flow directions shown on the maps and sections should be considered as broad conceptualizations. A nearly vertical fault striking southwest to northeast separates the northwestern part of the site underlain by the Lockatong Formation from the southeastern part, which is underlain by the Stockton Formation. In the Lockatong Formation, general groundwater-flow directions were toward P&T wells. The P&T wells limited the flow of groundwater in the Lockatong Formation from the site into the adjacent areas and contained most groundwater contamination within the site. A groundwater divide bisected the site; groundwater in the western part generally flowed to P&T wells 8BR, 15BR, 20BR, 29BR, 56BR, 91BR, and BRP-2, and groundwater in the eastern part generally flowed to P&T well 48BR. A groundwater divide also was present in the Stockton Formation. Groundwater west of the divide in the Stockton Formation generally flowed toward P&T well 22BR, and groundwater east of the divide generally flowed south and southeast, away from the site. Saprolite and fill from land surface to depths of 25 feet below land surface exhibit similar properties to those of porous media, and water levels in surficial wells were contoured using a porous media aquifer approach. Water levels in these surficial wells indicate that groundwater in the saprolite and fill flowed predominantly toward Gold Run and, to a lesser extent, the West Ditch spring that drains to Gold Run. In addition, some shallow groundwater was captured by the cone of depression in the fractured bedrock and was attributed to P&T well 48BR.

New Jersey↗

Regional hydrostratigraphic framework of Joint Base McGuire-Dix-Lakehurst and vicinity, New Jersey, in the context of perfluoroalkyl substances contamination of groundwater and surface water

A study was conducted by the U.S. Geological Survey, in cooperation with the U.S. Air Force, to describe the regional hydrostratigraphy of shallow aquifers and confining units underlying Joint Base McGuire-Dix-Lakehurst (JBMDL) and vicinity, New Jersey, in the context of contamination of groundwater and surface water by per- and polyfluoroalkyl substances (PFAS) potentially originating from JBMDL sources. The aquifers studied are two that crop out within JBMDL boundaries—the Kirkwood-Cohansey aquifer system and the Vincentown aquifer—and another aquifer near JBMDL that does not crop out at land surface—the Piney Point aquifer. The unconfined portion of the Vincentown aquifer and portions of the Kirkwood-Cohansey aquifer system that overlie the unconfined portion of the Vincentown aquifer are consolidated into, and described as, a single, separate unconfined aquifer system. Regionally extensive clay subunits that potentially create semiconfined hydrologic conditions within the mostly unconfined Kirkwood-Cohansey aquifer system also are identified. Two confining units were studied—the Manasquan-Shark River confining unit underlying the Kirkwood-Cohansey aquifer system, which includes the basal confining sediment in the Kirkwood Formation, and the Navesink-Hornerstown confining unit underlying the Vincentown aquifer. The hydrostratigraphic units are defined using available borehole geophysical logs, lithologic logs, and (or) drillers’ logs from 131 wells and are presented in a series of 8 aquifer structure maps and 12 cross sections. The framework positions JBMDL into a regional hydrostratigraphic structure for which higher-resolution delineation of the shallow aquifers can be constructed to determine potential pathways of PFAS contamination in groundwater to off-site drinking water wells in areas adjacent to JBMDL.

New Jersey↗

Hydrogeology of, simulation of groundwater flow in, and potential effects of sea-level rise on the Kirkwood-Cohansey aquifer system in the vicinity of Edwin B. Forsythe National Wildlife Refuge, New Jersey

The Edwin B. Forsythe National Wildlife Refuge encompasses more than 47,000 acres of New Jersey coastal habitats, including salt marshes, freshwater wetlands, tidal wetlands, barrier beaches, woodlands, and swamps. The refuge is along the Atlantic Flyway and provides breeding habitat for fish, migratory birds, and other wildlife species. The refuge area may be threatened by global climate change, including sea-level rise (SLR). The Kirkwood-Cohansey aquifer system underlies the Edwin B. Forsythe National Wildlife Refuge. Groundwater is an important source of freshwater flow into the refuge, but information about the interaction of surface water and groundwater in the refuge area and the potential effects of SLR on the underlying aquifer system is limited. The U.S. Geological Survey (USGS), in cooperation with the U.S. Fish and Wildlife Service (USFWS), conducted a hydrologic assessment of the refuge in New Jersey and developed a groundwater flow model to improve understanding of the geohydrology of the refuge area and to serve as a tool to evaluate changes in groundwater-level altitudes that may result from a rise in sea level. Groundwater flow simulations completed for this study include a calibrated baseline simulation that represents 2005–15 hydraulic conditions and three SLR scenarios―20, 40, and 60 centimeters (cm) (0.656, 1.312, and 1.968 feet, respectively). Results of the three SLR simulations indicate that the water table in the unconfined Kirkwood-Cohansey aquifer system in the refuge area will rise, resulting in increased discharge of fresh groundwater to freshwater wetlands and streams. As sea level rises, simulated groundwater discharge to the salt marsh, bay, and ocean is projected to decrease. Flow from the salt marsh, bay, and ocean to the overlying surface water is projected to increase as sea level rises. The simulated movement of the freshwater-seawater interface as sea level rises depends on the hydraulic-head gradient. In the center of the Forsythe model area, topographic relief is 23 feet (ft) and the hydraulic-head gradient is 0.0033. In the center of the Forsythe model area, the simulated interface moved inland about 600 ft and downward about 15 ft from the baseline simulation to scenario 3 as a result of a SLR of 60 cm. In the southern part of the Forsythe model area, the topography is flatter (relief of 8 ft) and the hydraulic-head gradient is smaller (0.001). In the southern part of the Forsythe model study area, the simulated interface in this area is projected to move inland about 200 ft from the baseline simulation to scenario 3 and does not move downward.

New Jersey↗

Landslide monitoring in the Atlantic Highlands area, New Jersey

Shallow and deep-seated landslides have occurred episodically on the steep coastal bluffs of the Atlantic Highlands area (Boroughs of Atlantic Highlands and Highlands) in New Jersey. The oldest documented deep-seated landslide occurred in April 1782 and significantly changed the morphology of the bluff. However, recent landslides have been mostly shallow in nature and have occurred during large storms with exceptionally heavy rainfall. These shallow landslides have resulted in considerable damage to residential property and local infrastructure and threatened human safety. The recent shallow landslides in the area (locations modified from New Jersey Department of Environmental Protection) consist primarily of slumps and flows of earth and debris within areas of historical landslides or on slopes modified by human activities. Such landslides are typically triggered by increases in shallow soil moisture and pore-water pressure caused by sustained and intense rainfall associated with spring nor’easters and late summer–fall tropical cyclones. However, the critical relation between rainfall, soil-moisture conditions, and landslide movement has not been fully defined. The U.S. Geological Survey is currently monitoring hillslopes within the Atlantic Highlands area to better understand the hydrologic and meteorological conditions associated with shallow landslide initiation.

New Jersey↗

Characterizing meteorological and hydrologic conditions associated with shallow landslide initiation in the coastal bluffs of the Atlantic Highlands, New Jersey

Meteorological and hydrologic conditions associated with shallow landslide initiation in the coastal bluffs of the Atlantic Highlands, New Jersey remain undocumented despite a history of damaging slope movement extending back to at least 1903. This study applies an empirical approach to quantify the rainfall conditions leading to shallow landsliding based on analysis of overlapping historical precipitation data and records of landslide occurrence, and uses continuous monitoring to quantify antecedent soil moisture and hydrologic response to rainfall events at two failure-prone hillslopes. Analysis of historical rainfall data reveals that both extended duration and cumulative rainfall amounts are critical characteristics of many landslide-inducing storms, and is consistent with current monitoring results that show notable increases in shallow soil moisture and pore-water pressure in continuous rainfall periods. Monitoring results show that shallow groundwater levels and soil moisture increase from annual lows in late summer-early fall to annual highs in late winter-early spring, and historical data indicate that shallow landslides occur most commonly from tropical cyclones in late summer through fall and nor’easters in spring. Based on this seasonality, we derived two provisional rainfall thresholds using a limited dataset of documented landslides and rainfall conditions for each season and storm type. A lower threshold for landslide initiation in spring corresponds with high antecedent moisture conditions, and higher rainfall amounts are required to induce shallow landslides during the drier soil moisture conditions in late summer-early fall.

New Jersey↗

Hydrogeologic barriers to the infiltration of treated wastewater at the Joint Base McGuire-Dix-Lakehurst Land Application Site, Burlington County, New Jersey

For the final phase of wastewater treatment operations at Joint Base McGuire-Dix-Lakehurst in Burlington County, New Jersey, treated effluent is pumped to 12 infiltration basins on a Land Application Site to recharge the unconfined Kirkwood-Cohansey aquifer system. Two of the 12 infiltration basins are operationally ineffective because discharged effluent fails to percolate and remains ponded on the basin surfaces. A study conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of Defense, investigated the potential hydrogeologic conditions preventing infiltration in these basins by testing the geophysical, lithological, and hydraulic characteristics of the aquifer material underlying the site. Saturated sand, sandy clay, and unsaturated sand were encountered in succession through the upper 4 feet of sediment below land surface at the two ineffective basins. Water levels in auger borings penetrating the clay and underlying dry sand were measured as deeper than water levels in nested auger borings in the saturated sand overlying the clay, which indicates a downward vertical gradient was established after removal of the clay in the deeper borings created a conduit for drainage from the surficial saturated sands. Ground-penetrating radar surveys and additional water levels measured in piezometer wells adjacent to the infiltration basins indicated a lack of connectivity between the ponded basin water and the regional water table, and demonstrated that perched conditions were not present in native formation materials outside the inoperable basins. Therefore, the near-surface low permeability clay is likely preventing infiltration from the basin surface and causes the ineffectiveness of the two basins for wastewater land application operations.

New Jersey↗

Transmissivity and storage coefficient estimates from slug tests, Naval Air Warfare Center, West Trenton, New Jersey

Slug tests were conducted on 56 observation wells open to bedrock at the former Naval Air Warfare Center (NAWC) in West Trenton, New Jersey. Aquifer transmissivity (T) and storage coefficient (S) values for most wells were estimated from slug-test data using the Cooper-Bredehoeft-Papadopulos method. Test data from three wells exhibited fast, underdamped water-level responses and were analyzed with the Butler high-K method. The range of T at NAWC was approximately 0.07 to 10,000 square feet per day. At 11 wells, water levels did not change measurably after 20 minutes following slug insertion; transmissivity at these 11 wells was estimated to be less than 0.07 square feet per day. The range of S was approximately 10 -10 to 0.01, the mode being 10 -10 . Water-level responses for tests at three wells fit poorly to the type curves of both methods, indicating that these methods were not appropriate for adequately estimating T and S from those data.

New Jersey↗