Geology ReportsSearch

Geology topics

A.A. Afifi

Publications and source records attributed to A.A. Afifi.

2 recordsLinked to original sources

Experimental chemical weathering of various bedrock types at different pH-values. 1. Sandstone and granite

Experimental chemical weathering of the so-called Old Rag Granite and Massanutten Sandstone, Virginia, U.S.A., has produced a comparison with the natural environment, and prediction of the effect of acid precipitation. The experimental results of the release of elements, dissolution of minerals, total rock weathered and the degree of weathering as function of volume of leachate were plotted. These data were compared with the natural environment. The use of the plots to predict the effect of high levels of rain acidity on weathering of these rocks is demonstrated. A nonexpandable 14-Å clay was developed from the alteration of biotite during the experimental chemical weathering of the granite at pH 4. This interstratified Al(OH)—mica clay resembles those of the soil developed on the granite and sandstone. Hydroxy-Al may be precipitating between the mica interlayers and producing a 14-Å spacing. Development of this clay by chemical alteration of biotite may change the current hypotheses about its origin in the soils of northeastern U.S.A. While Al-hydroxide seems to regulate Al concentrations in stream waters at the present level of rain acidity, it was found that at lower pH and in the presence of high sulfate concentrations, Al solubility may be controlled by Al-sulfate phase(s).

Virginia

Determination of dissolved aluminum in water samples

A technique has been modified for determination of a wide range of concentrations of dissolved aluminum (Al) in water and has been tested. In this technique, aluminum is complexed with 8-hydroxyquinoline at pH 8.3 to minimize interferences, then extracted with methyl isobutyl ketone (MIBK). The extract is analyzed colorimetrically at 395 nm. This technique is used to analyze two forms of monomeric Al, nonlabile (organic complexes) and labile (free, Al, Al sulfate, fluoride and hydroxide complexes). A detection limit 2 ug/L is possible with 25-ml samples and 10-ml extracts. The detection limit can be decreased by increasing the volume of the sample and (or) decreasing the volume of the methyl isobutyl ketone extract. The analytical uncertainty of this method is approximately + or - 5 percent. The standard addition technique provides a recovery test for this technique and ensures precision in samples of low Al concentrations. The average percentage recovery of the added Al plus the amount originally present was 99 percent. Data obtained from analyses of filtered standard solutions indicated that Al is adsorbed on various types of filters. However, the relationship between Al concentrations and adsorption remains linear. A test on standard solutions also indicated that Al is not adsorbed on nitric acid-washed polyethylene and polypropylene bottle wells. (USGS)

Water-Resources Investigations Report